RADCURE
Medical Physics 2024;51(4):3101–3109
- Methodology
- Software
- Validation
- Formal analysis
- Investigation
- Resources
- Data Curation
- Writing – Review & Editing
Doctoral thesis · 2026
Sejin Kim
Deep learning promises individualized prognosis in head and neck cancer, but the data are not analysis-ready, the models are not comprehensively evaluated, and the outputs are rarely aligned with a decision a clinician actually makes.
Deep learning promises individualized prognosis in head and neck cancer, but the data are not analysis-ready, the models are not comprehensively evaluated and characterized, and the outputs are not usually aligned with a decision a clinician actually makes. This thesis addresses these gaps, arguing that clinical deep learning is a data-engineering and evaluation problem at least as much as a modelling problem and that treating it that way is what makes a model deployable.
The first contribution is infrastructure. We curated and publicly released RADCURE: 3,346 head and neck cancer patients treated with definitive radiotherapy, the largest head and neck CT collection on The Cancer Imaging Archive. We published Med-ImageTools, an open-source Python package, which ensures high reproducibility, transparency, and significant time savings for researchers handling medical imaging datasets. Med-ImageTools is the processing engine for all of the projects built on the RADCURE dataset.
The second contribution is evaluation. Three studies investigate what imaging models learn and their implications for clinical deployment. A 12-model prognostic challenge on RADCURE showed the winning model used electronic medical record features plus tumour volume, and that engineered radiomics predictions correlated with tumour volume. A negative-control framework (READII-2-ROQC) destroyed image content nine different ways while preserving volume: a published survival signature’s performance was unchanged, an HPV-status signature drew its signal from the tumour periphery, and an imaging foundation model’s features derived from the background rather than the tumour. A segmentation benchmarking framework (SCARF) across 12 architectures and four blinded expert raters showed that geometric performance and clinical acceptability should not be expected to follow each other.
The third contribution is decision-aligned clinical models. A patient-level classifier of extranodal extension on radiotherapy planning CT, requiring no lymph node segmentation, reached AUROC 0.913 on the held-out test set and 0.671 on an external cohort, and stratified distant control comparably to the expert radiologist whose reads supplied its training labels. Chapter 5 presents preliminary work on Dosarex, a fully automated pipeline that reports per-tooth radiation dose on panoramic radiographs for osteoradionecrosis management.
From Table 2.1
RADCURE is the public dataset this thesis released, and every study after Chapter 2 draws a subset from it. Each dot below is one patient. Pick a study to see how many patients it used.
ThesisClinical deep learning is a data-engineering and evaluation problem at least as much as a modelling problem, and treating it that way is what makes a model clinically applicable.
Head and neck squamous cell carcinoma (HNSCC) arises from the mucosal surfaces of the oral cavity, pharynx and larynx, and its global burden is substantial, with over 830,000 new cases and 430,000 deaths per year, making it the seventh most common cancer worldwide Bray 2018. Approximately 30–40% of patients present with stage I or II disease, which is curable with surgery alone or definitive radiotherapy alone, with long-term survival in "approximately 70 to 90% of patients with early-stage disease." More than 60% present with stage III or IV disease, which "carries a high risk of local recurrence (15 to 40%) and distant metastasis, with poor prognosis (5-year overall survival, <50%)" Chow 2020.
The disease's modern epidemiology can be largely characterized by human papillomavirus (HPV): HPV-positive oropharyngeal carcinoma (OPC) is a biologically and prognostically distinct entity with separate classifications in the 8th edition of the AJCC/UICC staging system Lydiatt 2017. Its markedly better prognosis motivated treatment de-intensification: O'Sullivan and colleagues identified HPV-positive T1–3 N0–2c patients as low-risk candidates for de-intensification (3-year distant control 93%), while cautioning that N2c patients treated with radiotherapy alone had reduced distant control (73% vs 92% with chemoradiation) and are less suited for de-intensification strategies that omit chemotherapy O'Sullivan 2013.
Definitive management of locally advanced disease is multimodal, either with radiotherapy (RT) alone or with concurrent systemic therapy, or transoral surgery with risk-adapted adjuvant treatment. Each escalation in treatment intensity carries a toxicity cost, with trimodality therapy being the costliest. The central tension to manage is that the choice among these pathways is made before treatment, on imaging, under uncertainty.
Tumour extension through the lymph node capsule into surrounding tissue, namely ENE, is among the most consequential adverse features in head and neck cancer. There are three ways clinicians determine ENE: pathologic ENE (pENE), determined on the surgical specimen and treated as the gold standard; imaging-detected ENE (iENE), determined by a radiologist on pre-treatment imaging; and clinical ENE (cENE), determined via physical examination. While the gold standard has the highest sensitivity, it is inherently limited to patients who undergo neck dissection. It cannot be determined for the majority of definitively irradiated patients and is unavailable for every patient at the moment the initial treatment decision is made. Epidemiological studies reveal that 54-71% of HNSCC patient populations never undergo neck resection Schlichting 2019Zheng 2025.
Prognostic significance. Huang and colleagues showed that iENE carried a multivariable hazard ratio of 3.86 for overall survival Huang 2020. Meta-analysis across 18 studies (n=3,603 HPV+ OPC) pooled the effect at HR 2.64 for overall survival and HR 3.83 for distant control (iENE), versus HR 1.89 and 3.23 respectively for pENE, and neither form predicted locoregional control Benchetrit 2021. Understanding ENE as a marker of distant-spread biology is what later justifies distant control as a stratification endpoint.
Interobserver reliability. In a prospective, blinded international study, 34 experts (11 radiologists, 12 surgeons, 11 radiation oncologists) read preoperative CTs of HPV+ OPC against a pENE ground truth: median AUROC was 0.64 (95% CI 0.44–0.83) with no specialty showing performance beyond chance (AUROC 0.5) Sahin 2025.
Staging history. ENE entered the AJCC/UICC 8th edition (2017/2018) for non-viral HNSCC: any nodal metastasis with clinically overt ENE is N3b, where only unambiguous ENE, as determined by physical examination and supported by radiological evidence, should be present to assign a status of ENE-positive. ENE consideration was excluded for HPV-positive OPC in the 8th-edition Lydiatt 2017.
In the four-centre ICON-N cohort study, Huang and colleagues proposed reclassifying iENE-positive N1 disease as N2 disease and iENE-positive N2 disease as N3 disease for HPV-positive OPC, with iENE carrying an adjusted HR of 2.43 and a grade-dependent gradient (grade 1 AHR 1.73; grade 2, 2.14; grade 3, 3.64) Huang 2025. The updated 9th edition staging manual reflects these findings to include any extent of unequivocal iENE, when declared with high radiologic certainty, as a clinical N category modifier for HPV-positive OPC, while in nasopharynx only advanced-iENE modifies N3, and in non-viral HNSCC, unequivocal iENE is now accepted as a criterion for defining cN3 disease Brierley 2026.
The decision point is treatment selection in OPC, and the cost of error is trimodality therapy. ECOG-ACRIN E3311, a phase II trial of transoral surgery followed by risk-adapted adjuvant therapy in HPV-positive OPC, which excluded patients with matted or fixed pathologic adenopathy, assigned patients post-operatively by margins, nodal burden, and ENE extent (≤1mm vs >1mm). Despite the favourable selection, 31% of patients required escalation to chemoradiotherapy post-surgery, and ">1mm extranodal extension" was the dominant trigger, driving 77% of arm-D assignments Ferris 2022. A pre-treatment iENE determination with known operating characteristics could route patients with occult ENE away from primary surgery to avoid trimodality therapy, while preserving surgical de-intensification for patients without it.
The population-level scale of that cost is visible in claims data. Among the 626 resected patients in the SEER–Medicare locoregionally advanced HNSCC cohort, 56.3% received radiotherapy with or without systemic therapy after surgery: 33.1% surgery plus radiotherapy, 23.2% surgery plus systemic therapy and radiotherapy, while only 26.8% were treated with surgery alone Zheng 2025. Escalation after primary surgery is currently the norm rather than the exception, making pre-treatment estimate of nodal risk clinically relevant and actionable.
Radiotherapy planning workflow. Radiotherapy planning starts with acquiring a planning CT to design the delivery of radiotherapy dose, not to make a diagnosis. Curative radiotherapy for HNSCC conventionally delivers 70 Gy in daily 2 Gy fractions to gross disease, with lower doses to regions at risk of microscopic spread, and is combined with concurrent chemotherapy in most locally advanced cases. With the acquired image, a radiation oncologist contours the targets and organs at risk, which a planner uses to optimize beam parameters against dose objectives. The plan is reviewed by the departmental review board, and treatment is delivered over several weeks with daily image guidance. It is important that targets and organs-at-risk (OARs) contours follow standard nomenclature defined over the years by various consensus guidelines to ensure interoperability Grégoire 2011Mayo 2018. The gross tumour volume (GTV) is the disease that can be demonstrated on imaging and clinical examination, separated in head and neck practice into a primary volume (GTVp) and one or more nodal volumes (GTVn). The planning target volume (PTV) adds a geometric margin for set-up uncertainty. A consensus atlas defines 25 head and neck OARs on CT, which are contoured to minimize dose to preserve healthy, functional organs, and the TG-263 standard governs how they are named Brouwer 2015Mayo 2018.
Dose delivery and normal tissue complication. Intensity modulated radiotherapy (IMRT) varies the fluence across each beam direction, which inverse optimization methods solve for fluence patterns defining concave dose distributions that wrap around targets and spare adjacent normal tissue. In the PARSPORT randomized trial, parotid-sparing IMRT reduced xerostomia from 74% to 38% compared with conventional radiotherapy Nutting 2011. Mandibular osteoradionecrosis is one complication for which an NTCP model has been developed from mandible dose van Dijk 2021.
Planning CT. The planning CT and its accompanying data is the geometric model on which targets and normal tissues are drawn, and the physical model for dose calculation. It differs from a diagnostic neck CT based on its specific purpose. The patient is scanned in the treatment position with a mask and flat bed, the field of view must include the whole external contour for dose calculation, enlarging the in-plane pixel size, and slices are typically 2-3mm thick. CT numbers are converted to electron densities through a scanner-specific calibration curve. Davis and colleagues demonstrated how even minor shifts in CT-numbers can affect calculated dose Davis 2017. Therefore, the imaging acquisition protocols for planning CT are conservative and held fixed within a centre. These realities affect what a model trained on planning imaging data can learn. In machine learning, this can be useful because images from one institution are comparatively homogeneous, but less useful when an existing model is adopted by a new institution.
CT reconstructs the X-ray linear attenuation coefficient μ of each voxel from transmission measurements taken at many angles Hounsfield 1973Kalender 2006 and reports it in Hounsfield units (HU), normalized to water = 0 HU. Water and air are 0 and -1000 HU by definition, fat lies near -100 HU, unenhanced soft tissue ranges between roughly 20-80 HU, and cortical bone above 1000 HU. Soft-tissue attenuation tracks electron density and bone/iodine/metal attenuate more strongly through photoelectric absorption Goldman 2007a.
Acquisition and reconstruction. Tube voltage (kVp) sets the X-ray spectrum, which is usually set to 120 kVp for adult head and neck planning scans. Changing kVp can also shift CT numbers and alter HU enough to affect dose calculation Davis 2017. The tube current sets the number of photons, which affects image noise against how well low-contrast structures can be seen Goldman 2007b. Raw projections are turned into images either by filtered back projection (FBP) or by iterative methods. In FBP, the choice of reconstruction kernel trades spatial resolution against noise and iterative algorithms alter the texture of that noise Goldman 2007bWillemink 2019. Slice thickness sets through-plane resolution, with thicker slices being less noisy and averaging more tissue into each voxel. So a structure thinner than the slice, such as a nodal capsule or perinodal fat plane, is captured as a blend of itself and its neighbours. The reconstructed field of view divided by the image matrix sets the in-plane pixel size, which is most commonly set to a 512 x 512 matrix over the approximately 50cm field of a planning scan, yielding 1mm in-plane voxels.
Outcomes in head and neck oncology are times to an event, whether death, recurrence, or normal tissue complication. For many patients, the event has not occurred when the follow-up period ends. Survival analysis uses these right-censored observations instead of discarding them. The survival function is the probability of remaining event-free beyond a certain time t. The standard non-parametric estimator of the survival function is a Kaplan-Meier model, which formalized a method of leveraging censored data with exact event times (Figure 1.1).
The Cox proportional hazards model. The Cox-PH model is the standard method for relating patient characteristics to a time-to-event outcome Cox 1972. It describes each patient’s risk at any moment as the baseline risk and the model estimates how much each covariate scales the patient’s risk. The hazard ratio is the magnitude of the scale for each covariate, at which a value of 2 means that patients with the characteristic experience the event at twice the rate of otherwise similar patients without it. Censored patients contribute for as long as they were under observation. The output of the model is a risk score that ranks patients relative to one another, so to yield an absolute probability, Cox models need to be calibrated at each institution.
Radiomics is the high-throughput extraction of quantitative features from medical images to capture tumour phenotype and heterogeneity beyond visual assessment Lambin 2012Gillies 2015. The Image Biomarker Standardization Initiative (IBSI) established reference nomenclature and definitions by fixing the mathematical definition of the most commonly used features Zwanenburg 2020. PyRadiomics is one of the most widely adopted implementations, as it is open-source and often reused by the community van Griethuysen 2017. Features fall into four classes: shape, first-order, texture, and filtered. Shape features are computed based on the segmentation mask alone, without any consideration of intensity values. First-order features describe the histogram of intensities inside the mask. Texture features summarize the spatial arrangement of discretized gray levels through matrices measuring binned intensities. Filtered features repeat the first-order and texture calculations after wavelet or Laplacian-of-Gaussian filtering.
Radiomics signatures. The template of radiomic signatures was set by the four-feature CT signature of Aerts and colleagues, which was trained in lung cancer and remained prognostic in independent lung and head and neck cohorts Aerts 2014. It was later validated in 542 patients with oropharyngeal carcinoma from a different center, and it retained discrimination (C-index 0.628) Leijenaar 2015. A CT signature for HPV status gave AUROCs between 0.70 and 0.80 across validation sets from several centres Leijenaar 2018. Outside head and neck cancer, a radiomics nomogram for nodal metastasis in colorectal cancer kept its discrimination in an independent validation cohort (C-index 0.778) Huang 2016, and a signature of CD8 cell infiltration was associated with survival on immunotherapy on an external cohort Sun 2018. In HPV-related oropharyngeal carcinoma, a radiomic signature predicted distant metastasis with a C-index of 0.670, and tumour volume alone reached 0.674 Kwan 2018. The signature of Aerts and colleagues was itself shown to be a surrogate for volume Welch 2019. Successful external validation shows that a signature is generalizable on new populations, beyond just capturing tumour biology.
Supervised learning models learn to predict a label given an input by minimizing a loss over a training set. What matters most is the model’s performance on patients it hasn’t seen during training, so data is partitioned into training set, fine-tuning set to choose hyperparameters, and a held-out test set used once for final evaluations. When the same data are used to select a model and to report its performance, the estimate is optimistic Varma 2006, and leakage between partitions is a recurring failure in medical imaging Varoquaux 2022.
Neural networks and deep learning. A neural network stacks layers of linear transformations and non-linear activation functions and learns its features based on the loss function of the input-label pair, instead of having them defined in advance LeCun 2015. Parameters are fitted by backpropagation and different optimization strategies such as stochastic gradient descent or Adam Kingma 2015. The loss is non-convex, so models with different initializations can converge to different solutions despite sharing identical architectures and ensembles can help reduce those variations. Convolutional neural networks (CNNs) learn visual features through multiple layers of convolution kernels, which are multiplied across the image at every position. Alternating convolutions with downsampling enlarges the receptive field with depth, so early layers learn edges and textures, later layers learn larger patterns and parts, and eventually learn object representations, which a global pooling step followed by a linear classifier converts final feature maps into a class probability Litjens 2017Yamashita 2018.
Evaluation. The AUROC score is the probability that a random positive case scores higher than a random negative one Hanley 1982, and two models tested on the same patients need a paired comparison DeLong 1988. AUPRC is more informative when positives are uncommon, but its baseline equals the prevalence, so it is more informative when evaluating imbalanced datasets Saito 2015. Calibration is the agreement between predicted probabilities and observed frequencies, and a model that discriminates well can still be poorly calibrated in a new cohort Van Calster 2019. Net benefit weighs true positives against false positives at the threshold where a clinician would act Vickers 2006. Geometric metrics such as the Dice Similarity Coefficient (DSC) and Hausdorff Distance (95HD) are used to evaluate the accuracy of segmentation models. Beyond these metrics, the clinical implications of a model are commonly assessed by comparing its predictions with those of clinicians on the same cases, by testing it in an external cohort that reflects the intended population, and ultimately by studying its effect on patient outcomes Park 2018. Although randomized controlled trials are regarded as the gold standard for the last of these, they are not always feasible, and few models have so far reached clinical deployment Kelly 2019.
Clinical 3D volumes are scarce, expensive to label, anisotropic, and encode signal in calibrated intensities rather than natural-image statistics. Dominant strategies of adapting natural imaging methods include 3D convolutions trained from scratch, 2.5D slice-wise approaches, and axial-coronal-sagittal (ACS) convolutions that repurpose ImageNet-pretrained 2D kernels for 3D input.
ACS convolutions are composed of 2D convolution kernels of size K × K, split by output channel into three groups, reshaped into K × K × 1, K × 1 × K and 1 × K × K kernels, and convolved over the axial, coronal and sagittal views of the volume Yang 2021. The three view-based feature maps are concatenated along the channel axis, and no 3D fusion layer is required additionally because the view-based output features will be automatically fused by subsequent convolution layers Yang 2021. Since the kernels are split rather than replicated, the parameter count is exactly that of the 2D model and the converted models could load the 2D weights directly, so any ImageNet-pretrained 2D CNN becomes natively 3D.
The volume confounder. A key theme of our studies is that tumour and nodal volume is a powerful, cheap prognostic signal that dominates imaging models. Welch and colleagues’ re-analysis of the four-feature Aerts radiomic signature refit as "MW2018," achieved an external validation C-index of 0.64. Fitting the same signature using features extracted from images with randomized signal intensities achieved similar performance, with C-index of 0.64 and 0.60 for H&N and lung, respectively. Tumour volume alone reached C-index 0.64, and three of the four signature features correlated strongly with volume. The entirety of the signature was a surrogate for tumour volume, and intensity and texture values did not provide any meaningful signal for prognostication Welch 2019. A subsequent study generalized the diagnosis, with nearly 30% of radiomic features correlated strongly with volume, the first principal component of the full feature set tracked volume at ρ=0.78, and volume-independent features alone could not stratify survival Traverso 2020.
The metric problem. Segmentation quality can be measured in at least a dozen ways, and the choice of measure is not neutral. The Metrics Reloaded consensus, developed by an international consortium through a multi-stage Delphi process, treats validation metrics as proxies for the domain interest and argues that inappropriate metric choice is one reason many artificial intelligence developments in medical imaging do not reach clinical practice Maier-Hein 2024. It identifies three classes of failure: An inappropriate problem category, such as framing a detection task as segmentation so that a missed object is never penalized; Poor metric selection, such as using the Dice similarity coefficient (DSC) where target structures are consistently small relative to the voxel grid; Poor metric application, such as ignoring hierarchical structure when aggregating across patients or institutions. Reinke 2024Maier-Hein 2024. What current literature does not establish is how model performance metrics track clinical utility. It indicates which metric is defensible for a given problem description but does not indicate whether a radiation oncologist would accept the resulting contour. No published study measures the correspondence between geometric metric rank and clinical acceptability directly, according to our best knowledge.
Kann and colleagues trained DualNet, a dual-input 3D CNN merging a dimension-preserving and a size-invariant stream of the segmented nodal volume on 270 surgical patients (653 segmented nodes) with node-by-node pathologic correlation, reaching AUROC 0.91 for ENE on held-out nodes ≥1 cm and external validation on two independent cohorts resulted in AUROC 0.84 and 0.90 Kann 2018Kann 2020. However, there are three structural problems with the node-level paradigm.
First, the training population is non-representative. pENE supervision means learning from surgically treated cohorts that differ systematically from the definitively irradiated majority. Since these node-level models are trained with pENE as ground truth, they learn from a surgically treated population that is non-representative of the broader HNSCC cohort, much of which is treated non-surgically Kim 2026. Kann’s study also states its own limitations that there were no cases of ENE identified pathologically when ROI diameter was <10mm in this study, and so it is unclear if the models would generalize to sub-centimeter lymph nodes Kann 2018.
Second, node-level models depend on a node contour at inference, via either expensive clinician time or an upstream segmentation model. Ye and colleagues automated that dependency with nnU-Net auto-segmentation feeding the locked DualNet classifier Ye 2026. Dayan and colleagues also trained a nnU-Net lymph node segmentation model upstream of a radiomics classifier Dayan 2026. While automated segmentations provide scale, it can become an unvalidated dependency; SCARF quantifies how often auto-segmentations are acceptable and how poorly geometric metrics predict it.
Third, aggregation to the patient level is not anchored to an iENE ground truth. Ye’s AI-ENE model predicted at least one AI-ENE node in 70.8% of patients, roughly four times the 15–20% iENE prevalence reported in comparable definitive-RT cohorts Kim 2026. As the cohort is non-operative, the study itself acknowledges the number of false positives and negatives in this study is unknown Ye 2026. The AI-ENE node count is prognostic Ye 2026, but a determination that flags 71% of patients cannot map onto TNM-9, which is defined relative to unequivocal iENE with high radiologic certainty. Without an iENE ground truth to anchor the patient-level aggregation, Ye’s AI-ENE outputs cannot be directly compared to a radiologist's determination and are difficult to integrate into the 9th edition TNM staging framework. Dayan and colleagues’ recent work on a patient-level iENE model achieved AUROC 0.81 against the radiologist reference, with AI-iENE C-indices exceeding the radiologists' own reads (0.79 vs 0.68 for distant control). However, the study is limited by its single-centre design without external validation, only including HPV-positive OPC, segmentation-dependent model design, and incorporating no supervised deep learning training with iENE labels Dayan 2026.
The main gap in the literature is that no published model predicts patient-level iENE from the planning CT every RT patient already receives, with an end-to-end supervised deep learning model, without lymph node segmentation, and with external validation.
The Cancer Imaging Archive is the largest public collection of cancer imaging, ranging across a diverse range of modalities such as CT, MRI, PET, ultrasound, mammography, X-ray, and also connects with multimodal data sources such as clinical, pathology and genomic data Clark 2013. Radiotherapy planning CT is the key imaging modality for making clinical decisions in head and neck cancer cases. However, H&N imaging was not readily available publicly, totaling ~1700 samples before the release of RADCURE, much of which was not easily interoperable due to the lack of adherence to FAIR principles Wilkinson 2016. The data-hungry nature of deep learning methods meant that this effectively limited machine learning research to only a few academic centers with access to large internal clinical databases.
DICOM, the clinical imaging standard, was designed in the 1980s–90s for interoperability among devices, not for analysis Mildenberger 2002. 3D scans are stored slice-by-slice, so researchers must traverse the file hierarchy and stitch series together, and vendor implementations usually differ. A common technical gap for data curation specific for medical imaging research is that one patient may have multiple RTStruct and RTDose files with one imaging acquisition, one RTStruct and RTDose with multiple images, or worst of all, multiple RTStruct and RTDose files with multiple images. Preprocessing curated datasets for machine learning research from public archives such as TCIA with over 140 datasets and rigorous quality assurance processes, still requires manually reorganizing directories and matching radiation therapy structures.
The methodological consequence is that preprocessing choices are often arbitrary and can greatly impact model training and performance but are not transparently disclosed in publications. Preprocessing is a scientific choice presented as a chore. The stakes were stated by Haibe-Kains and colleagues in their response to a prominent closed-pipeline AI study: "the absence of sufficiently documented methods and computer code underlying the study effectively undermines its scientific value … [and] for scientific efforts in which a clinical application is envisioned and human lives would be at stake, we argue that the bar of transparency should be set even higher" Haibe-Kains 2020. Similarly, the joint ESTRO/AAPM guideline formally recommends reproducibility checklists for AI development and warns that even released source code may be insufficient if specific (in-house) coding libraries prevent reproduction Hurkmans 2024.
Clinical deep learning is a data-engineering and evaluation problem at least as much as a modelling problem and treating it that way is what makes a model clinically applicable. We define a model as clinically applicable if its development study is transparent and reproducible, the model can be deployed reliably without manual intervention, and able to inform a specific clinical decision.
Chapter 2: Curate and publicly release the largest head and neck cancer imaging dataset and publish open infrastructure that easily prepares medical imaging datasets for machine learning research. Hypothesis: automated, scripted curation can supersede manual curation in fidelity while being transparent, faster, and reproducible by design.
Chapter 3: Investigate what imaging-based prognostic and segmentation models actually learn, using a multi-team challenge, a configurable negative-control framework, and a model clinical acceptability evaluation framework. Hypothesis: a substantial fraction of published imaging "signal" is attributable to tumour volume or context, and geometric performance metrics do not translate to clinical acceptability.
Chapter 4: Build and externally validate a patient-level iENE classifier on planning CT with no node-segmentation dependency, explicit characterization of volume correlation, and model evaluation anchored to a clinical decision. Hypothesis: a patient-level model can exceed volume and clinical baselines and stratify outcomes comparably to a clinician.
Chapter 5: Extend the methodology from prognosis to supportive care by building a fully automated pipeline that reports radiation dose per tooth on the routine panoramic radiographs, without any manual contouring or operator intervention. Hypothesis: per-tooth dose reporting can be produced unattended from the planning DICOM study to help dentists make better informed and more granular decisions to manage tooth extraction and osteoradionecrosis.
HypothesisAutomated, scripted curation can supersede manual curation in fidelity while being transparent, faster, and reproducible by design.
Nothing downstream in our works is possible without analysis-ready data. Med-ImageTools is the preprocessing engine for RADCURE Welch 2024Kim 2025, for the READII-2-ROQC negative-control study Scott 2026, for SCARF’s nine-institution 3,293-patient corpus Marsilla 2026, for the iENE study Kim 2026, and the Dosarex pipeline. Med-ImageTools was leveraged to develop novel survival methods: Deep-CR-MTLR on RADCURE Kim 2021, and beyond the scope of this thesis, used to validate a novel survival modelling method, FastCPH, on an external head and neck dataset Yang 2022. Four downstream chapters depend on one package. That is the argument for treating infrastructure as a scientific contribution rather than as preamble: when a single curation engine underlies the data release (Chapter 2), all three evaluation studies (Chapter 3), and the clinical models (Chapter 4 + 5), the transparency and correctness of that engine become scientific properties of everything built on it.
This chapter presents the two halves of that foundation: the largest public head and neck dataset curated and released, RADCURE (Ch.2.2), and the software used to process it, Med-ImageTools (Ch.2.3).
In the realm of healthcare research, there is a growing emphasis on the development of automated pipelines and computational analysis of patient medical data. Specifically, in cancer care, volumetric images are abundant and routinely collected at multiple time points during a patient’s treatment Gillies 2015. Recent studies have demonstrated the application of computational analysis and machine learning techniques to retrospective cancer imaging data. However, the often limited size of the datasets used can result in studies with inconclusive results Morin 2018. For robust analysis, particularly in diseases with complex or heterogeneous manifestations, large datasets are critical to ensure comprehensive coverage of all disease phenotypes.
Each type of cancer introduces distinct challenges in diagnosis, prognosis, and treatment strategy formulation. These challenges are further amplified when applying machine learning techniques when adequate representation of disease phenotypes within the datasets is absent. Head and neck cancer (HNC) is an example of a highly heterogeneous disease Lydiatt 2017 that encompasses 13 different disease sites, each impacted by the inherently complicated anatomy of the head and neck. Additionally, factors such as human papillomavirus (HPV) status can impact primary and secondary endpoints such as overall survival and distant metastasis. These complexities present formidable challenges for computational analyses and machine learning frameworks, which could potentially be mitigated by leveraging larger datasets.
Several research groups have employed extensive HNC datasets to glean new clinical insights. Imaging biomarkers or radiomic signatures have been derived using hand-engineered imaging features from images and contours to forecast patient outcomes, often serving as a foundational comparison for prognostic imaging tasks Aerts 2014Vallières 2017. Despite the large dimensionality of radiomic features that attempt to capture various complexities of the tumour from imaging, there is evidence suggesting that these radiomics features are prone to being confounded by tumour volume Welch 2019. Deep learning models aim to overcome this limitation by further abstracting radiomic features beyond hand-engineered feature definitions. These methods have been used for prognostic tasks involving the prediction of extranodal extension Kann 2018, as well as the automation of clinical tasks such as organs-at-risk segmentation Nikolov 2021Oreiller 2022. The success of these studies, and their resulting contributions to both academic and clinical knowledge, is reliant on large, highly curated datasets.
Open-source data repositories, such as The Cancer Imaging Archive (TCIA) Clark 2013, enhance the transparency and rigor of research, granting access to substantial datasets that may otherwise be inaccessible to individual researchers or institutions. These repositories are instrumental in promoting reproducible science and the continuous evaluation of published research. In this chapter, we introduce RADCURE Clark 2013Kazmierski 2023, a single-institution dataset comprised of 3,346 HNC computed tomography (CT) images with associated radiotherapy (RT) contours and outcomes data that is available on TCIA. RADCURE, with its significant patient count, not only reflects the diverse presentation of HNC patients treated at our institution but also contains the variability necessary to characterize this heterogenous disease site thoroughly. The curation and dissemination of RADCURE aims to stimulate further research and foster novel scientific inquiries in the realm of medical image analysis.
RADCURE comprises data for 3,346 HNC patients treated at the Princess Margaret Cancer Centre with definitive radiation therapy (RT) or chemoradiation between 2005 and 2017. The collection of this dataset for research purposes was approved by the institutional Research Ethics Board (REB # 17-5871). RADCURE is the largest of its kind to be made openly available on TCIA (Figure 2.1), and contains important imaging, clinical, demographic and treatment information data (Figure 2.2, Supp.Table 1).
Imaging and Contour Information. For each patient, a single RT planning CT image is provided along with the corresponding normal and non-normal tissue contours. Contours are included for the primary gross-tumour-volume (GTVp), relevant gross lymph nodes, and organs-at-risk (OAR). CTs were acquired on Toshiba, GE, and Philips machines. On average, pixel spacing was 0.96mm, with an in-plane-resolution of 512 by 512. Average slice thickness was 2.20mm and the average number of slices was 183. Contrast was administered during CT simulation as per institutional clinical guidelines. Overall, 61.5% of patients were imaged with an administered contrast agent, and this variable is provided in the associated clinical datasheet to allow dataset users to select studies with/without contrast enhancement as needed for analysis.
The GTVp was delineated according to Princess Margaret Cancer Centre’s Head and Neck Site Group’s contouring guidelines. The majority of contour sets were peer-reviewed at weekly site group RT quality assurance rounds.
Demographic, Clinical and Treatment Information. Clinical data, including demographics, staging, treatment, and outcomes, were prospectively assembled via an in-house prospective database (“Bioclinical Anthology of Outcomes in Head and Neck Cancer”) where outcome data was collected at point-of-care Wong 2010. Demographic data includes age at the time of diagnosis and patient sex. Treatment data includes prescribed radiation dose and status of systemic therapy. Clinical data includes the disease subsite, staging according to the 7th edition of the American Joint Committee on Cancer (AJCC) staging manual (includes T, N, M and overall stage), ECOG (Eastern Cooperative Oncology Group) performance status (i.e., patient’s level of daily functioning as it relates to daily activity, ability to care for themselves, etc.), feeding tube presence, and p16 status used as a marker indicating human papillomavirus (HPV) status. Supplementary Table 1 includes variable distributions for select features of the dataset.
Outcome Data. Binarized 2-year survival and continuous overall survival in months (duration of survival from diagnosis date to death or censoring) are provided for all patients along with cause of death, and time to local, regional, or distant metastasis (Figure 2.3). All data is up to date as of November 2021.
Data Extraction and Translation. An in-house data mining and processing system MIRA (University Health Network, Toronto, Canada) was used to extract and translate RADCURE imaging and structure set data from our institution’s radiation treatment planning and oncology information systems. The input to the data extraction was a set of patient identifiers, radiation treatment start dates and radiation dose-fractionations provided from our institution’s HNC anthology (Figure 2.4).
The mining platform uses a series of data comparisons to select treatment planning files corresponding to delivered plans in our oncology information system. The origin of the CT simulation and contour data was the external beam radiation treatment planning system (TPS) Pinnacle (Philips Radiation Oncology Systems, Fitchburg, WI). The primary CT dataset used for treatment planning is stored in the DICOM format within a patient directory for each radiation treatment plan in the Pinnacle file store. The treatment planning structure set, treatment beam descriptions and numerous dose files corresponding to plan/beam/control-point dose distributions are also stored in this directory in Pinnacle-specific file formats. The treatment beam file is parsed and used in the data validation, but the file is not extracted or translated into a DICOM RT-Plan due to missing beam parameters (e.g. total beam MU). The dose files were not used in the extraction.
Given a patient identifier for data extraction, MIRA locates the patient directory and validates the treatment planning data contained within through a series of heuristics that ensure 1) the radiation dose prescription of the treatment plan matches the input dose-fractionation, 2) the treatment plan has been delivered and recorded in our oncology information system Mosaiq (Elekta, Stockholm, Sweden) and 3) the first delivered fraction was within three days of the input start date recorded in the HNC anthology. Out of the 4130 patients submitted as inputs to the extraction, approximately 3300 matched a single unique treatment plan. The remaining cases, which were abandoned, either matched multiple treatment plans (e.g., multiple ambiguous copies of a treatment plan with potential differences in contour data), or more commonly, did not match any treatment plan (e.g., due to errors in input data, delays to treatment start that resulted in date discrepancies with the input filter, planned split treatment courses that resulted in radiation dose discrepancies with the input filter, etc.).
Upon validation, the DICOM CT image was extracted from Pinnacle and the contour file was translated to a DICOM RT-STRUCT. All RT-STRUCT contours were further validated by ensuring each contour was located on a CT image slice and fully contained within the image bounding box. Manual verification of a subset of the extracted CT images and RT-STRUCT contours was performed by visual inspection and comparison to CT images and RT-STRUCT objects manually exported from the Pinnacle TPS. All extracted and translated data were transferred to a secure storage location on a computational cluster within our institution.
Data Curation. After RADCURE was placed on our institutional computational cluster, additional validation and filtering was completed using both electronic medical records (EMR) and DICOM data.
We filtered EMR data to only include patients with M0 disease and with more than two years of follow-up if the patient was still alive at last follow-up. We performed minimal pre-processing on the EMR data but did perform text case normalization of disease sites.
We further filtered based on the patient DICOM CT Image and RT-STRUCT. Verification of these files included the ability to successfully load/open the files using SimpleITK Lowekamp 2013. The RT-STRUCT file also needed to contain a non-empty gross-tumour-volume, where GTV, GTVp, and high-risk target volume (HTV) were acceptable naming standards. It was assumed, based on institutional guidelines, that this contour did not contain lymph nodes.
RT-STRUCT files were curated to contain the patient’s primary gross tumour volume and organ-at-risk contours. All region of interest (ROI) names were standardized according to AAPM TG-263 nomenclature guidelines Mayo 2018, with an adaptation for nodal targets. All nodal targets appear in RT-STRUCT files as GTVn_[X], where X is the original nomenclature used for that ROI. At our center, all nodes are labeled based on the cervical neck level Grégoire 2014, and if multiple nodes exist an additional roman numeral was added to enumerate the nodes within the level, e.g. the third node in neck level 2B would have a name GTVn_iii2B.
This curation was largely scripted using functionality found in the python package Med-ImageTools Kim 2025. This automated curation process was chosen over human curation to increase transparency and provenance of the data.
Data Format. All imaging and structure set data are provided in standard DICOM CT and RT-STRUCT formats, respectively. All data were de-identified and uploaded to TCIA using their standard pipelines. De-identification is a multi-stage process utilizing layers of CTP (Clinical Trials Protocol) clients. Details of this process can be found in the TCIA documentation Clark 2013. Briefly, an ID-mapper file is provided to the CTP that maps institutional patientIDs to a TCIA ID. Next, a burned-in pixel filter checks specific DICOM tags that may suggest PHI on an image – thereby preventing transmission to TCIA. Finally, all images are submitted to TCIA using Aspera enabled high speed transfers that utilize Fast Adaptive and Secure Protocols (FASP). This process is enabled by a script that removes or blanks standard tags known to contain PHI, offsets DICOM header dates and generates unique identifiers (UID) that include TCIA-side embedded root IDs.
Data Overlap with Previous TCIA Data. It is important to note that although RADCURE is a cohort of 3,346 patients, 606 of these patients were previously released on TCIA as the OPC-Radiomics database. These 606 OPC-Radiomics patients have been consolidated with the newly released 2,740 patients and are contained in a single database named RADCURE. The OPC-Radiomics database has been removed from TCIA. However, an ID mapping sheet between OPC-Radiomics and RADCURE ID names is available on TCIA.
The patients from OPC-Radiomics contain RT-STRUCT files that have undergone standardization of contour names consistent with the new 2,740 patients. Additionally, the endpoints for the OPC-Radiomics patients were updated during the curation of the clinical datasheet for the newly published patients. It is recommended that the new clinical datasheet be used for all future use of the OPC-Radiomics, and that previous work utilizing these 606 patients be updated if necessary.
The RADCURE dataset, with its comprehensive collection of patient images, offers substantial opportunities for both academic and clinical research. It stands as a preeminent single-institution imaging dataset, boasting roughly 3.5 times the patient imaging data compared to other HNC datasets on TCIA. This rich amalgamation of imaging, clinical, demographic, and treatment data positions RADCURE as a prime resource for a host of image analysis research initiatives.
CT images provide structural information of patient anatomy such as the size, shape and relative location of tumours, lymph nodes and critical organs. Additionally, CT images can be used to quantify tissue density heterogeneity Lubner 2017, identify vascular invasion of tumours Zhao 2022 and characterize extracapsular extension (e.g. of cancerous lymph nodes) Carlton 2017. These anatomical and biological features motivate the potential role of CT combined with machine learning for prognostication for head and neck cancer, which may yet uncover subtle image features that have novel prognostic value. As demonstrated by the previous work done with RADCURE Reiazi 2021Arrowsmith 2020Kim 2023, or with other similar datasets, potential studies could include outcome prediction with appropriate baseline clinical comparators or analysis of the relationships between provided clinical, demographic and treatment information and imaging features. Notably, deep learning techniques require more data than traditional machine learning techniques and are highly susceptible to over-fitting Mateus 2023. As such, by providing a larger dataset of CT images (two to tenfold) than used in previous studies that demonstrate promising results, we believe the RADCURE dataset has the potential to power future work that may yield new and more generalizable models.
Furthermore, RADCURE also contains variability in image acquisition parameters despite being collected at a single institution. This variability will allow researchers to gain a better understanding of the impact of these parameters on imaging features. Other imaging analysis research projects that will benefit from RADCURE include quality assurance projects. The dataset has been highly curated, but there are opportunities for research pertaining to artifact detection, DICOM metadata analysis, and the relation of these artifacts to radiomic features, or other intermediate or end point data.
Although the size of RADCURE provides many opportunities for academic and clinical research communities, it does have limitations. A significant constraint is its reliance on the 7th edition of the AJCC staging manual for clinical staging, rendering the clinical data outdated compared to the 8th edition. This limitation is not unique to RADCURE but is prevalent across open datasets, including those for HNC on TCIA. Consequently, any model developed using RADCURE must be approached with caution if it is to be applied to patient cohorts staged under the new AJCC protocols.
Additionally, RADCURE is missing information required for a complete view of a patient’s disease. For instance, RADCURE contains a limited number of clinical, demographic and treatment features. Compared to other HNC datasets on TCIA it is a comprehensive list, but variables such as histology and feeding tube status are limited and may lead to biased results. We plan to include additional clinical and treatment features as they become available. However, certain demographic variables (e.g., race and income) are not collected at our institution. Chart information is also not available for these patients. This includes information like chemotherapy dose and toxicity measurements, which are required for complete clinical interpretation of the data. Clinical and planning target volumes and treatment planning dose data have also been excluded from this dataset, limiting the ability to study institutional treatment guidelines or prognostic modeling leveraging dosimetric factors.
RADCURE consists exclusively of CT images collected for radiation treatment planning. This is in contrast to other publicly available head and neck datasets that contain multimodal images, such as PET (Figure 2.2). These additional imaging modalities may provide important quantitative information, such as standardized uptake values or tissue relaxation time, which are related to tissue function and could improve our understanding of a patient’s clinical indicators and their disease characteristics beyond the anatomical and density information provided by CT Bogowicz 2017. However, many questions still remain regarding clinical utility Bogowicz 2019, reproducibility Mateus 2023, and the biological meaning that drives prognostic modeling based on clinical images Tomaszewski 2021.
| Project | Subset definition | n |
|---|---|---|
| Full public release (Ch. 2) | all | 3,346 |
| Survival Modelling (Ch.3.2-3.3) | M0, 2Y+ follow-up, no prior surgery, GTVp available | 2,552 |
| READII-2-ROQC (Ch.3.4) | successfully processed GTVp | 2,994 |
| SCARF (Ch.3.5) | all 19 essential OARs delineated | 582 |
| iENE (Ch. 4) | primary OPC with iENE labels | 915 |
| Dosarex (Ch. 5) | RADCURE-CT / -DOSE / -DX | 885 |
Radiology is a powerful modality of data for clinical work, giving clinicians the ability to see the inner workings of the human body, that cannot be seen from the outside Brant 2012. They can inspect in 2D or 3D, the anatomy surrounding the disease, enabling key information to make life-altering clinical decisions. While regular images taken on cameras or phones are stored in a variety of accessible formats, medical images are encoded in the Digital Imaging and Communications in Medicine (DICOM) standard file format Mildenberger 2002.
The DICOM standard was developed in the 1980s due to the increasing need for an interoperable standard for 3D medical images across various manufacturers Mildenberger 2002. A key feature of DICOM is the plethora of metadata fields that store information beyond imaging data, such as patient information, clinical variables, and acquisition parameters. As modern medical practice evolved over the years, the DICOM standard has grown to accommodate more metadata fields and encompass new imaging modalities or therapy information Mildenberger 2002. This type of data format is unsuitable for imaging analysis as the relevant voxel array must be manually accessed through DICOM hierarchy Mildenberger 2002. Since 3D scans are acquired on a slice-by-slice basis, researchers must stitch together data from multiple files to create one 3D image, adding delays caused by disk reads and consolidation processes Mildenberger 2002.
Specialties that rigorously use imaging data are heavily reliant on DICOM, one of which is radiation oncology. Images are used along every step of the clinical workflow: from deriving a precise diagnosis, to designing personalized radiation therapy plans, and delivering each radiation dose with the appropriate alignment and orientation with brief scans. While the defined standard serves as a good guideline, each manufacturer has slightly different implementations. This is especially the case for DICOM-RT (radiotherapy), a subset of modalities for communicating radiotherapy data Mildenberger 2002. The DICOM-RT standard includes additional modalities such as RTStruct for contour data, and RTDose for radiotherapy dose maps and dose-volume histograms (DVH). While the broad adoption of the DICOM standard to accommodate for various use cases has allowed it to become the de facto standard for encoding, storing, and transferring of medical images, its comprehensive nature has made it difficult for researchers to navigate for the purposes of imaging projects.
The Cancer Imaging Archive (TCIA) is one of the largest public repositories of DICOM images available, with over 140 datasets consisting of more than 60,000 patients Clark 2013. The datasets undergo a quality assurance process to ensure the recorded clinical variables are coherent and the DICOM files are not missing any important metadata fields. These stringent processes and infrastructure have allowed TCIA to become one of the most comprehensive repositories for biomedical imaging datasets, inviting researchers from different fields to explore new ideas and methods on high quality datasets.
While the underlying data and its annotations are of clinical quality, processing the dataset for subsequent analysis requires a non-trivial amount of effort: manually reorganizing directories and matching radiation therapy structures (RTStruct), referred to as DICOM-RT contours, and radiation therapy plans (RTDose/RTPlan) to its corresponding images Law 2009. This is partly due to the inherently complex nature of clinical datasets, as data is collected on the basis of need and iterative improvements, not structured scientific inquiries. It is also sometimes due to the lack of familiarity from machine learning (ML) and artificial intelligence (AI) researchers in handling the DICOM files for their analytical pipelines. Typical AI imaging datasets have pairwise associations of one image to a single ground-truth label Deng 2009. However, one patient in clinical datasets may have multiple RTStruct and RTDose files with one imaging acquisition, one RTStruct and RTDose with multiple images, or worst of all, multiple RTStruct and RTDose files with multiple images Vallières 2017. In any of these cases, the directories are not always intuitively structured to help researchers understand which files correspond with another.
Once researchers have successfully curated the dataset into an organized structure for analysis, in order to process the raw dataset into analysis-ready format, they must choose from a variety of processing parameters, ranging from voxel spacing, RTStruct name parsing, and Hounsfield unit (HU) window levels, based on the design of their analysis. While these implicit decisions for image processing are often arbitrary, they can greatly impact model training and performance, but are not transparently disclosed in publications Sabottke 2020. This leads to the difficulty of reproducibility of medical deep learning research, adding another deterrence to clinical adoption.
Furthermore, there are a limited number of software packages that researchers can use to quickly parse DICOM-RT files into analysis-ready arrays. Chief among those, SlicerRT Pinter 2012, an extension of 3DSlicer Pieper 2004, an open-source DICOM visualization tool, has been widely used by the medical imaging community. Despite its broad adoption, batch data processing with Slicer requires custom scripting in Python, to be executed in the Slicer ecosystem. Rather than simply installing a package within their Python environment, users must install the Slicer application and add any other dependencies, not provided by Slicer, into the application environment. As a result, machine learning projects relying on Python for data preprocessing will have their code fragmented across multiple environments–the Slicer environment for data processing, and another Python environment for data analysis and machine learning. RT-Utils is a lightweight, open-source Python package designed to handle RTStruct files with relative ease and simplicity, allowing users to easily export contours into segmentation masks in arrays. However, the functionalities of RT-Utils are limited to the RTStruct modality. PlatiPy is a recent processing library and analysis toolkit for medical imaging, mainly designed for the context of radiation therapy. It features a comprehensive set of image manipulation functions such as registration and atlas-based segmentation methods, allowing researchers the flexibility to process imaging data into any format they need. However, PlatiPy does not solve the inherent complexity of clinical datasets, and researchers must spend hours reorganizing the data into a structured set of samples and labels. The current landscape of open-source medical imaging tools highlights the need for a native Python package that can parse large DICOM/DICOM-RT datasets to an analysis-ready format for ML/AI development in a consistent, reproducible workflow.
| Feature | 3DSlicer + SlicerRT |
RT-Utils | PlatiPy | PyDicer | Med-ImageTools |
|---|---|---|---|---|---|
| Native Python interface | ● | ● | ● | ● | |
| Command-line interface | ● | ||||
| Handles RTSTRUCTs | ● | ● | ● | ● | ● |
| Handles RTDOSEs | ● | ● | ● | ● | |
| Handles images (CT/MRI) | ● | ● | ● | ● | |
| Built-in image transformations | ● | ● | ● | ||
| Exports to analysis-ready NIfTI/NRRD | ● | ● | ● | ● | |
| Image registration | ● | ● | |||
| Built-in bulk processing of entire datasets | ● | ||||
| Automatic parsing of DICOM metadata | ● | ● |
To address the limitations of the current software packages used to process medical images, we developed Med-ImageTools, a new Python package designed to help researchers transform complex medical datasets into analysis-ready format with few lines of code. It is also focused on helping researchers develop transparent and reproducible medical image processing pipelines by addressing most of the boilerplate code required for image transformations and processing parallelization. While Med-ImageTools has many modular functions for image, contour, and dose input/output (IO) built on popular frameworks such as SimpleITK, TorchIO and PyDicom, such functionalities are redundant and available in other open-source packages as well. We have tailored our core features towards broader use cases and development workflows, instead of modality or disease type specific workflows, such as BIDS Gorgolewski 2016. Our main contribution is in the development of AutoPipeline and will mainly discuss its functionalities and implementation.
AutoPipeline is the main feature of Med-ImageTools that allows users to easily process raw DICOM clinical datasets into analysis-ready Nrrd or NIfTI files, which are commonly used file formats for 3D volumetric data. It is interfaced using the command line, so the user only needs to submit a single command into the terminal to execute the three core steps in the AutoPipeline process (Figure 2.5):
Crawl: The crawler opens every DICOM file in the dataset using Pydicom, indexing important metadata, such as unique identifiers, modality information, and references to other modalities. This produces a database of every unique image and DICOM-RT modality.
Connect: In this step, each patient’s indices of unique files of different modalities are connected to form one coherent sample. There are various heuristics the user may choose to connect samples. The default option is through DICOM metadata, as datasets derived from clinical practice are expected to have corresponding metadata that references unique identifiers of the parent image or RTPlan. Alternative heuristics allow users to deal with anomalies with corrupted or missing metadata.
Process: All identified samples are processed according to imaging and transformation parameters defined by the user. The user can configure parameters such as the pixel spacing in mm(s), which specific modalities to process, the number of cores they want to use for multiprocessing, and define nnU-Net specific flags as well. The images are manipulated using SimpleITK without requiring any user intervention.
The AutoPipeline feature can be directly interfaced once Med-ImageTools is installed. To install Med-ImageTools, the recommended method is via the PyPI package repository in a virtual environment. Running the ‘pip install med-imagetools ’ command will install the latest version of Med-ImageTools and its associated dependencies defined by the requirements.txt file. Now, whenever the user is in the virtual environment where Med-ImageTools is installed, they can directly interact with the AutoPipeline feature in the command line. The simplest way to use it is through ‘autopipeline input_directory output_directory’. This will automatically process the dataset located in ‘input_directory’ and process them at ‘output_directory’ using the default parameters. Med-ImageTools will generate files that are not analysis-ready images, such as the autogenerated ‘Dataset Index’ (Figure 2.5), and store them in a folder named “.imgtools” at the path of the ‘input_directory’. This is to ensure a convenient user experience and intuitive folder structure by hiding extraneous components. An extended tutorial of AutoPipeline and all its associated parameters are available on our documentation page. At the present time, there are no minimum system requirements for Med-ImageTools as it will run regardless of number of processor cores or memory (RAM). However, if the researcher can leverage greater number of cores and RAM, it will allow the AutoPipeline to be parallelized and process the data faster.
As the crawl and process steps are computationally intensive, all steps in AutoPipeline are automatically parallelized using the joblib backend to efficiently leverage all available computational resources. While the output of the AutoPipeline processing can result in terabytes of images, the crawl is limited to a few kilobytes of a metadata database, making it an ideal asset to share with other researchers as a detailed descriptor of a medical imaging dataset. We therefore propose to attach the crawled metadata spreadsheet to large TCIA datasets to allow Med-ImageTools users to process large datasets much faster and more efficiently. These databases are expected to save up to 1000 core-hours of crawling per dataset, accumulating over 2000 core-hours of computation saved per user. By standardizing a commonly repeated imaging processing pipeline into a single unified package, we hope to improve the reproducibility and transparency of future medical imaging research.
We showcase the value of the AutoPipeline implemented in Med-ImageTools v1.0.0 for processing three medical imaging datasets, namely Pancreatic-CT-CBCT-SEG from TCIA, a private liver metastasis dataset and a pre-release extraction of RADCURE, in order of complexity and sizes. In each use case, we initially describe the process.
Using pre-crawled datasets on the Pancreatic Cone-beam Computed Tomography (CBCT)
40 patients with abdominal CBCT scans and their associated contours of regions of interest and other organs, publicly available on TCIA
The Pancreatic-CT-CBCT-SEG dataset Hong 2022 was processed twice using AutoPipeline: once from scratch, and once using the pre-crawled dataset, available on the tcia-crawls branch of Med-ImageTools. Processing from scratch, the dataset took 10.77 core-hours (10:46), whereas using a pre-crawled database allowed the processing to finish in 9.14 core-hours (9:08) (Figure 2.6a). The pre-crawled database reduced processing time by 1.63 core-hours, representing an 18% increase in total processing speed or 2 minutes 27 seconds per patient. The time saved from pre-crawled databases is not a substantial quantity for datasets with less than 100 patients. However, when scaled up to larger TCIA datasets such as OPC-Radiomics (n=606) Kwan 2019 and NLST (n=26254) NLST 2011, it can save researchers 24.7 core-hours and 1072 core-hours, respectively (Figure 2.6b). The resources saved are reported in core-hours to allow a hardware-agnostic estimation of time and cost savings. While it may vary depending on the research infrastructure utilized, these databases can result in significant savings in billing.
Comparing manual vs automatic processing of the liver metastasis dataset
97 patients with abdominal CT scans and their associated contours of liver and gross tumour volumes (GTV), data access described in data availability section below.
The liver metastasis dataset was processed using the Slicer API to export a CT scan along with segmentations of the liver and GTVs for each patient. In the initial DICOM dataset, each patient had a single RTSTRUCT file along with one or more CT series, one of which was referenced by the RTSTRUCT. The first step of the process was to load the entire DICOM dataset into the Slicer DICOM database via the graphical user interface (GUI), to make the data available inside the Slicer scripting environment. Then, we wrote a script to export an initial set of candidate segmentations for the liver and GTVs for each patient, along with the referenced CT scan. This script leveraged the Slicer API to identify the CT series that was referenced by the patient’s RTSTRUCT and used an ad hoc string filtering function to identify candidate segmentations. Finally, we iteratively refined the set of exported RTSTRUCT contours on a patient-by-patient basis, based on visual checking, and physician feedback. Although this step was time-consuming, there is, at present, no substitute for manual verification to ensure data quality and correctness. On the other hand, the initial database construction and export script using the Slicer API achieved results roughly analogous to the automatic output of AutoPipeline. The export script is approximately 170 lines long and took 7.5 hours to run on the whole dataset–this script is available on our GitHub repository. In contrast, on the same 6-core machine (16GB RAM, Windows 10), AutoPipeline took only 2.3 hours with 1 command line, mainly accelerated by parallelization (Figure 2.6c). The authors involved in validating Med-ImageTools’ effectiveness on this private dataset had no active involvement in the development of the package before its application. This highlights the package’s robustness on unseen data and its potential utility for multi-centre collaborations to ensure consistent processing. One use case might be to enable federated learning platforms to automatically process each node’s datasets without requiring any user intervention.
Comparing manual vs automatic processing of the RADCURE dataset
3,219 patients with head and neck CT scans and their associated contours of organs at risk (OAR) for radiotherapy (pre-release extraction; the public TCIA release contains 3,346 patients).
At the time of this benchmark, the RADCURE extraction comprised 3,219 head and neck cancer patients and their radiotherapy planning data Welch 2024. The data arrived as two separately structured exports, meaning the directories and DICOM metadata were organized differently. The directories from each system were restructured using general heuristics, and any abnormal cases were flagged and manually organized. We used SimpleITK and PyDicom to extract the imaging and contour data from the DICOM files, which underwent a similar iterative process as the liver metastatic dataset. The script is over 1000 lines long and takes 30-40 hours to run on the whole dataset using a single core–this script is available on our GitHub repository. AutoPipeline scales dramatically based on the number of cores available, which enables the entire dataset to be processed in 40 minutes using 32 cores, automatically managing the directories from different systems and extracting the contours (Figure 2.6d). These results demonstrate Med-ImageTools’ design does not bottleneck any multiprocessing backends and brings meaningful acceleration on very large datasets, such as RADCURE.
One caveat of these comparisons is that the iterative process of filtering appropriate contours, which can add weeks to months of cooperation between the researchers and the physicians, was already conducted in the original processing steps. Various data cleaning steps that require human intervention, such as sorting contour names or selecting specific subseries acquisitions, cannot be fully automated for the foreseeable future. The Med-ImageTools team aims to add features to the package that will assist researchers in these steps, such as adding a flag to visualize all unique contours without requiring code, adding subseries detection to the crawler, and publishing a set of regular expressions (regex) that can be used to automatically choose contours from prominent head and neck datasets on TCIA. Also, these comparisons do not take into account the time it takes for researchers to develop the manual processing scripts. Hence, the actual amount of time saved for the researcher may be greater than the reported times.
Although ML and AI promise to revolutionize the way we leverage medical imaging data for improving care, they require large datasets to train computational models that can be implemented in clinical practice. However, processing large and complex medical imaging datasets remains an open challenge. To address this issue, we developed Med-ImageTools, a new open-source software package to automate data curation and processing while allowing researchers to share their data processing configurations more easily, lowering the barrier for other researchers to reproduce published works.
The AutoPipeline feature will improve the accessibility of raw clinical datasets on public archives, such as TCIA, allowing machine learning researchers to process analysis-ready formats without requiring deep domain knowledge. Another exciting potential of Med-ImageTools lies in building automated workflows using AutoPipeline. For a researcher to build an end-to-end automated pipeline starting from clinical DICOM datasets to outputting an inference-ready deep learning model, they could easily develop a reproducible processing step by configuring only the command line interaction of Med-ImageTools, making debugging and custom configurations simpler since the developer would not have to rely on a static script.
While our package aims to address challenges encountered across a few medical imaging labs, we acknowledge that there may be infinite other issues that may arise in DICOM datasets. This is one of the key reasons why our package is open-source for community involvement and contribution. Also, as stated previously, there are certain onerous tasks that cannot be automated and must undergo human supervision. These aspects of researcher-clinician collaboration are an inevitable part of medical imaging research and are subject to delay.
No single solution can completely solve the reproducibility crisis of medical deep learning research, due to a variety of issues ranging from ambiguous data processing techniques to stochasticity of model training. However, community-centered open-source solutions and increased clinical adherence to data standards, such as contour nomenclature Mayo 2018, can incrementally improve research quality and reproducibility, and make medical deep learning research more accessible for everyone.
Alongside the package itself, this thesis's projects standardized on pixi for environment management: language-agnostic, cross-platform dependency solving with a self-documenting lock file, task automation, and multi-environment features. The iENE inference repository (Chapter 4) and the Dosarex repository (Chapter 5) both ship pixi environments, making it possible to reproduce the study’s full results with a single command.
The Pancreatic-CT-CBCT-SEG dataset is available on The Cancer Imaging Archive at: https://doi.org/10.7937/TCIA.ESHQ-4D90. The pre-crawled Med-ImageTools database of the Pancreatic-CT-CBCT-SEG dataset is available on GitHub at: https://github.com/bhklab/med-imagetools/raw/tcia-crawls/csvs/imgtools_Pancreatic-CT-CBCT-SEG.csv.
The liver dataset was collected as part of the study titled Radiomics artificial intelligence modelling for prediction of local control for colorectal liver metastases treated with radiotherapy with Institutional Review Board and informed consent. Interested individuals should contact the senior author for access to the dataset, which will be made available following standard institutional rules for IRB and HIPAA.
The RADCURE dataset is publicly available on TCIA Welch 2024. Data published on TCIA are subject to TCIA data usage policies and restrictions.
Source code available from: github.com/bhklab/med-imagetools also available on the PyPI software repository: pypi.org/project/med-imagetools.
Scripts for this study’s use cases are available from: github.com/bhklab/med-imagetools/tree/F1000Research
Archived source code at time of publication: https://doi.org/10.5281/zenodo.14766792
| Metric | Value |
|---|---|
| Current release | v2.15.0 (30 Apr 2026) |
| Commits | 752 |
| GitHub stars / forks / watchers | 60 / 11 / 3 |
| Open issues | 32 |
| PyPI downloads | 665 last month |
| Distribution | PyPI, Docker Hub, uvx |
| License | MIT |
| CI/CD | GitHub Actions, Codecov, ReadTheDocs, semantic versioning |
RADCURE provides 3,346 planning CTs with target and organ-at-risk contours, clinical variables and outcomes, roughly 3.5 times the patient imaging data of other head and neck datasets on TCIA (Ch.2.2). Med-ImageTools converts such DICOM collections into analysis-ready volumes through a single configurable command (Ch.2.3). RADCURE was curated largely with Med-ImageTools, and the RADCURE extraction was in turn the largest dataset on which Med-ImageTools was benchmarked. The benchmarks support the hypothesis that scripted curation is faster and more transparent than manual curation (Ch.2.3.4). Built-in parallelization ensures that researchers have access to their processed data much faster than they have in the past through manual curation or single-plexed processing scripts. More importantly, a larger gain is found in dataset-specific scripts of more than 1,000 lines that were replaced by one command whose parameters can be stored, reported, and rerun.
Preprocessing is a scientific choice, not a chore and this chapter's contributions to the literature and this thesis’ subsequent chapters demonstrate how one engine serves four evaluation studies and two clinical pipelines (Table 2.1). With the data and its processing fixed and open to inspection, the next chapter examines what models learn from them.
HypothesisA substantial fraction of published imaging “signal” is attributable to tumour volume or context, and geometric performance metrics do not translate to clinical acceptability.
Before building a clinical model, we pose two questions to frame our understanding of the studies in this chapter.
Is the signal real, or is it size? Tumour volume is prognostic, cheap, and already clinically legible. An imaging model that silently re-derives volume adds cost without information. Chapters 3.2 to 3.4 measure how much published imaging "signal" is volume in disguise—first observationally, by correlating challenge submissions' predictions with volume, then causally, by destroying image content while preserving volume and watching whether performance notices.
Does a good metric mean a usable model? Geometric segmentation metrics are the field's currency, but the clinical question is whether an expert would accept the contour. Chapter 3.5 measures the gap between the two for organs at risk; if geometric accuracy does not guarantee acceptability even for well-defined OARs, a lymph node contour cannot be assumed reliable, which motivates the most consequential design decision in Chapter 4: removing the dependency on lymph node segmentation.
The RADCURE prognostic modelling challenge (RADCURE-challenge) was organized by the Radiomics for Radiotherapy Research initiative at UHN, open to participants within UHN, with a predefined public protocol on GitHub. The challenge opened 14 Apr 2020 and final submissions were due 25 Jul. In total 12 models were evaluated and the winners were announced 31 Jul 2020.
Cohort: Princess Margaret Cancer Centre patients (n=2,552 from 2005–2017, definitive RT or chemoRT, ≥2 years follow-up or death, M0, and no prior surgery). Split by date of diagnosis to simulate a pseudo-prospective trial: 1,802 train / 750 test with participants blinded to test outcomes.
Endpoints and metrics: The primary endpoint is binary 2-year overall survival. The secondary endpoint is lifetime risk and survival curves in 1-month intervals to 23 months. AUROC was the primary metric, with AP as tiebreaker and C-index is used to compare risk predictions.
Organizer baseline models: baseline-clinical (age, sex, T/N stage, HPV); baseline-volume (primary tumour volume alone); baseline-radiomics (1,316 PyRadiomics v2.2.0 features, mRMR selection, grid-searched L2 logistic regression, 5-fold CV) van Griethuysen 2017Ding 2005.
| Rank | Description | AUROC | AP | C-index |
|---|---|---|---|---|
| 1 | Deep multitask logistic regression using EMR features and tumour volume. | 0.823 [0.777–0.866] | 0.505 [0.420–0.602] | 0.801 [0.757–0.842] |
| 2 | Fuzzy logistic regression (binary) and Cox proportional hazards model (risk prediction) using EMR features and tumour volume. | 0.816 [0.767–0.860] | 0.502 [0.418–0.598] | 0.746 [0.700–0.788] |
| 3 | Fuzzy logistic regression (binary) or Cox proportional hazards model (risk prediction) using EMR features and engineered radiomic features. | 0.808 [0.758–0.856] | 0.490 [0.406–0.583] | 0.748 [0.703–0.792] |
| 4 | Multitask logistic regression using EMR features. | 0.798 [0.748–0.845] | 0.429 [0.356–0.530] | 0.785 [0.740–0.827] |
| 5 | 3D convnet using cropped image patch around the tumour with EMR features concatenated before binary classification layer. | 0.786 [0.734–0.837] | 0.420 [0.347–0.525] | 0.774 [0.725–0.819] |
| 6 | 2D convnet using largest GTV image and contour slices with EMR features concatenated after additional nonlinear encoding before binary classification layer. | 0.783 [0.730–0.834] | 0.438 [0.360–0.540] | 0.773 [0.724–0.820] |
| 7 | 3D DenseNet using cropped image patch around the tumour with EMR features concatenated before multitask prediction layer. | 0.780 [0.733–0.824] | 0.353 [0.290–0.440] | 0.781 [0.740–0.819] |
| 8 | Multilayer perceptron (MLP) with SELU activation and binary output layer using EMR features. | 0.779 [0.721–0.832] | 0.415 [0.343–0.519] | 0.768 [0.714–0.817] |
| 9 | Two-stream 3D DenseNet with multitask prediction layer using cropped patch around the tumour and additional downsampled context patch. | 0.766 [0.718–0.811] | 0.311 [0.260–0.391] | 0.748 [0.703–0.790] |
| 10 | 2D convnet using largest GTV image and contour slices and binary output layer. | 0.735 [0.677–0.792] | 0.357 [0.289–0.455] | 0.722 [0.667–0.774] |
| 11 | 3D convnet using cropped image patch around the tumour and binary output layer. | 0.717 [0.661–0.770] | 0.268 [0.225–0.339] | 0.706 [0.653–0.756] |
| 12 | Fuzzy logistic regression (binary) and Cox proportional hazards model (risk prediction) using engineered radiomic features. | 0.716 [0.655–0.772] | 0.341 [0.272–0.433] | 0.695 [0.638–0.749] |
The winner was a deep multi-task logistic regression (MTLR) on EMR features plus tumour volume, which outperformed every other model on AUROC at FDR < 5% except the runner-up. Ablation analyses of the winning model localize its signal: EMR-only drops AUROC to 0.798, replacing the volume input with a 3D convnet image representation drops it to 0.766. One combined model using engineered features (number 3) performed worse than the exact same model using EMR features and volume only (number 2), indicating that the added complexity of radiomic features reduces performance. Risk stratification at a predicted 2-year event probability of 0.5 gave hazard ratios of 8.64 (best combined), 5.96 (best EMR-only) and 4.50 (best radiomics), all p<10⁻¹⁸.
| Model class | ρ | Our interpretation |
|---|---|---|
| baseline-radiomics | 0.85 | predictions driven primarily by volume |
| Engineered-radiomics submission (#12) | 0.79 | same, worse |
| Two of three convnets | > 0.5 | moderate-to-strong |
| Best imaging-only model (#9) | 0.22 | weak — with AUROC 0.766, better than volume alone |
| Top combined models (#1, #2) | < 0.5 | use volume as an input yet exploit EMR beyond it |
The top models fall into an optimal region of low (but nonzero) volume correlation and high performance. Note that while models 1 and 2 used tumour volume as one of the input variables, their predictions moderately correlate with volume (0.4 < ρ < 0.6), indicating they can exploit additional information present in the EMR features. Higher correlation leads to decreased performance as the predictions are increasingly driven by volume only. Most radiomics-only models fall in the moderate-to-strong correlation region (ρ ≥ 0.5), although deep learning predictions correlate at notably lower level than engineered features. Interestingly, the best radiomics submission (number 9) achieves the lowest volume correlation, suggesting that it might be possible to learn volume-independent image-based predictors.
The top three models plus the best deep learning submission were evaluated across three external datasets: HN1 (n=137) Wee 2019, MDACC (n=627) Grossberg 2018, and GPCC HN (n=298), an external private dataset. The three datasets are significantly heterogeneous in disease site, HPV status and outcome prevalence.
The top model (number 1) was the best performing model in two datasets, with an AUROC of 0.852 in HN1 and 0.742 in MDACC. In GPCC HN, it was slightly exceeded by model number 2 (AUROC 0.662 vs 0.686), but the confidence intervals overlapped between all models within each cohort. Performance dropped in two of three datasets but remained better than random (p < 0.0001).
ML combined with simple prognostic factors outperformed multiple advanced CT radiomics and deep learning methods. Although deep learning–based imaging models generally outperformed approaches based on handcrafted features, none proved superior to the combined EMR-volume model, even when combined with EMR data. The paper’s conclusions match those of Ger and colleagues, who did not find significant improvement in prognostic performance of handcrafted CT and PET imaging features in HNC compared with volume alone and of Vallières and colleagues, whose best performing model for overall survival also combined EMR features and volume Ger 2019Vallières 2017.
The RADCURE-challenge evaluated twelve models against a single binary endpoint, two-year overall survival, which pools death from cancer with death from other causes, making clinical decisions hard to derive, since those decisions trade cancer control against treatment-related harm. Deep-CR-MTLR was designed to extend MTLR from a single-event setting to competing risks, by fitting a separate set of interval parameters for each mutually exclusive event and normalizing over both time and event, so that the model predicts a cause-specific cumulative incidence function rather than an all-cause survival curve Yu 2011Kim 2021. The resulting objective is similar to DeepHit, but based on MTLR’s unique discretized time bin function rather than a discrete-time likelihood Lee 2018. The model also carries an image arm that the top challenge submission did not, a 3D convolutional network over a 50 × 50 × 50 voxel patch centered on the primary tumour, pooled to 512 dimensions and concatenated with the clinical vector before a shared MTLR head. If CT holds tumour-specific prognostic signal, the image arm should add more to the prediction of cancer death than to the prediction of death from other causes, and a pooled endpoint would hide that difference Kim 2021.
Competing-risks formulation. For each patient we observe a time to event or censoring, an event indicator e that is 0 for censoring and otherwise runs from 1 to E, and a feature vector x. Here E = 2: death from the primary cancer and death from other causes, the latter including comorbidity and second cancers. Each patient experiences at most one of the two. The quantity of interest is the cumulative incidence function (CIF), the probability that event e has occurred by a given time. Fitting a single-event model to each cause in turn, with the other cause treated as censoring, gives biased probabilities unless the risks are independent, which is generally not the case Kalbfleisch 2002.
MTLR divides the time axis into K intervals, the last of them open-ended, and fits one logistic regressor per interval boundary. The regressors are tied together so that predictions stay consistent over time: a patient predicted to have died cannot be alive at a later boundary Yu 2011. Deep-CR-MTLR gives each event e its own weights θe,k and bias be,k at each boundary k, and scores the outcome “event e in interval i” by summing over the boundaries from i onward, with a score of zero for the final interval. Because the events are mutually exclusive, the scores are normalized over all events and intervals together, which gives the probability that event e occurs in interval i:
| $p_{e,i}(x) = \frac{exp\ \left( s_{e,i}(x) \right)}{\Sigma_{i' = 1}^{K}\Sigma_{e' = 1}^{E}exp\ \left( s_{e',i'}(x) \right)}$ | (3.1) |
|---|
Training minimizes the negative log-likelihood with an L2 penalty on the MTLR weights. A patient with an observed event contributes the probability of that event in that interval. A censored patient could still experience either event, and so contributes the summed probability of both events over every interval from the censoring interval onward.
Multimodal architecture. Deep-CR-MTLR follows the Neural MTLR approach, in which a neural network replaces the linear predictor beneath the MTLR layer Fotso 2018. The clinical input is a vector of 24 values built from age at diagnosis, sex, disease site and stage, ECOG performance status, HPV status, radiation dose and use of chemotherapy, with categorical variables one-hot encoded and continuous variables normalized. The image arm is a 3D convolutional network applied to the 50 × 50 × 50 voxel patch around the primary tumour: a 50mm cube at 1mm isotropic spacing, centered on the centroid of the primary GTV, with intensities clipped to −500 to 1,000 HU. The network has two convolutional blocks. Each block is two convolutions, each followed by batch normalization and ReLU activation, and then 2 × 2 × 2 max pooling with stride 2. The first convolution uses a 5 × 5 × 5 kernel and the rest 3 × 3 × 3, and the channel count rises through 64, 128 and 256 to 512. Global average pooling reduces each channel to a single value, giving a 512-dimensional image representation. This is concatenated with the clinical vector into a 536-dimensional vector and passed through three fully connected hidden layers with ReLU activations, shared between the two modalities. The output of the shared layers takes the place of x in equation 3.1, and the MTLR layer returns the probabilities of equation 3.1.
The convolutional network, the shared layers and the MTLR weights are trained jointly by gradient descent, so the image representation is learned against the competing-risks likelihood itself. The architecture was selected after testing several depths and kernel sizes on the training and fine-tuning data, and was kept small on purpose to limit overfitting on a cohort of this size. The convolutional network, the shared layers and the MTLR weights are trained jointly by gradient descent, so the image representation is learned against the competing-risks likelihood itself. The architecture was selected after testing several depths and kernel sizes on the training and fine-tuning data, and was kept small on purpose to limit overfitting on a cohort of this size.
Cohort and outcomes. The study used the RADCURE-challenge cohort and its split by date of diagnosis (n = 2,552; 1,802 for training and fine-tuning, 750 for testing), so every test patient was diagnosed after the most recently diagnosed training patient. Each patient had a pre-treatment planning CT with the primary tumour contoured by a radiation oncologist, and all were followed for at least two years or until death. Because the test set holds the most recent diagnoses, its follow-up is shorter and it has fewer events (Table 3.3): 102 cancer deaths and 39 deaths from other causes.
| Outcome | Training/fine-tuning (n = 1,802) | Test (n = 750) |
|---|---|---|
| Alive or censored | 1,065 (59%) | 609 (81%) |
| Death from cancer | 342 (19%) | 102 (14%) |
| Death from other causes | 395 (22%) | 39 (5%) |
Training. The model was implemented in PyTorch with PyTorch Lightning and trained with the Adam optimizer at a learning rate of 10−4 Paszke 2019Falcon 2019Kingma 2015. Training patches were augmented with random in-plane rotation, random flips and additive Gaussian noise. The number of hidden layers in the shared network and the regularization constant was chosen on the fine-tuning set. The network weights and the MTLR weights were regularized separately, because the MTLR weights needed a stronger penalty to keep predictions smooth across time intervals. The time axis was discretized at quantiles of the observed event times, with the number of interval boundaries set by the square root of the number of training patients with an observed event. The MTLR layer has 58 outputs, 29 for each event.
Comparators and metrics. To separate what each modality adds, the multimodal model was compared with three single-modality models: the shared network on clinical variables alone (neural MTLR), the convolutional network on images alone, and a linear MTLR on clinical variables. Two cause-specific metrics were reported for each event. The two-year AUROC, computed between the predicted CIF at two years and the indicator of that event within two years, measures how well a model picks out patients at high short-term risk. The concordance index (C-index) Harrell 1996, computed on a lifetime risk score that aggregates the predictions over all intervals, measures how well it ranks patients over the whole follow-up.
Deep-CR-MTLR reached two-year AUROC 0.774 and C-index 0.788 for cancer-specific death, and 0.781 and 0.761 for other-cause death, the highest value on all four measures (Table 3.4). The same network on clinical variables alone reached 0.768 and 0.756 for cancer-specific death, whereas the convolutional network alone reached 0.742 and 0.746 Kim 2021. The neural MTLR on clinical variables beat the linear MTLR on every measure, which points to non-linear interactions among clinical variables as one source of the gain.
| Model | AUROC | C-index | ||
|---|---|---|---|---|
| Cancer | Other | Cancer | Other | |
| Linear MTLR (clinical) | 0.740 | 0.724 | 0.747 | 0.679 |
| Convnet (images) | 0.742 | 0.740 | 0.746 | 0.707 |
| Neural MTLR (clinical) | 0.768 | 0.755 | 0.756 | 0.726 |
| Deep-CR-MTLR (clinical + images) | 0.774 | 0.781 | 0.788 | 0.761 |
Extending MTLR to competing risks changed the estimator but maintained the same conclusion of the RADCURE-challenge. The addition of imaging to clinical variables yielded a modest improvement in the prediction of cancer-specific death, with two-year AUROC increasing from 0.768 to 0.774 and the C-index from 0.756 to 0.788. The improvement in the model’s predictions for both death from cancer and from other causes (C-index 0.726 to 0.761) indicates that the signal likely does not reflect tumour biology alone.
The main limitation of the study is that its reported differences are point estimates from a single institution without external validation. Therefore, these results should be interpreted as descriptive and are more so a demonstration of how Deep-CR-MTLR allows future studies to investigate competing risks.
The results of the RADCURE-challenge and Deep-CR-MTLR suggest that the limit lies in the information contained in the features, not in the estimator fitted to them. This next study tests this hypothesis directly, by destroying image content and measuring whether performance changes.
Role of the candidate: Second author. Contributed to the conception and design of the experiment and software framework, curated and processed the imaging data with Med-ImageTools, and contributed to the interpretation of results and the direction of subsequent analyses.
READII-2-ROQC generalizes Welch and colleagues’ experiment into a reproducible framework. Welch and colleagues shuffled image intensity values by randomly permuting voxels across the entire 3D dataset and refitting the Aerts signature (MW2018) on both original and randomized images yielded similar C-indices on both, demonstrating that the signature was a surrogate for tumour volume Welch 2019. READII-2-ROQC (Radiomic Extraction and Analysis for DICOM Images to Refine Objective Quality Control) makes this experiment configurable with nine controls rather than one, and extends it from engineered features to an imaging foundation model. If a feature is merely a proxy for volume, its biological interpretability and utility in explainable AI frameworks are fundamentally compromised Scott 2026.
Stage 1: Curation. Med-ImageTools converts DICOM and segmentation to NIfTI, extracts header metadata to ensure spatial registration, generates a unique sample identifier per image–mask pair for provenance, programmatically separates multiple ROIs, and emits a metadata index.
Stage 2: Negative-control generation. Three permutation classes crossed with three spatial regions give nine controls:
Permutations: Random (voxel intensities drawn from a discrete uniform distribution over the region's original range); Sample (resampling with replacement from the original distribution, preserving intensity frequencies); Shuffle (reordering existing voxels with the exact histogram preserved, all spatial texture destroyed).
Regions: Full image, ROI (tumour), Background (everything else).
Geometry (direction, origin, spacing) is copied from the original to maintain mask registration, and cropping/resizing occur after control generation, so the available voxel distribution is not altered. The Full × Shuffle-permutation configuration replicates Welch’s 2019 study.
Stage 3: Feature extraction.
PyRadiomics 3.0.1a: all default features plus Compactness1 (to reproduce Aerts), across original, wavelet, square, square-root, logarithm, exponential and gradient filters — 1,317 features per image; bin width and gray-level discretization 25; resampling to 1 × 1 × 1mm³ van Griethuysen 2017.
FMCIB (Foundation Model for Cancer Imaging Biomarkers) Pai 2024: 4,096 features from public pretrained weights, with images cropped to 50 × 50 × 50 voxels around the tumour centroid without masking the ROI.
Stage 4: Packaging. A Snakemake pipeline emits a RadiomicSet MultiAssayExperiment R object per dataset, published on ORCESTRA with a per-dataset Zenodo DOI and an auto-generated "Data Nutrition Label" recording pipeline version, metadata and provenance.
Datasets: LUNG1 421 Aerts 2014 + HN1 137 Wee 2019 + RADCURE 2,994 Welch 2024 = 3,552 tumour volumes. The RADCURE train/test split is read directly from the RADCURE-challenge column of the released clinical spreadsheet Kazmierski 2023.
Radiomic signatures evaluated: the Aerts overall survival signature (fixed coefficients, not refit) Aerts 2014, and the Choi HPV status signature (refit as logistic regression on RADCURE OPC training data, tested on the RADCURE test split, externally validated on HN1) Choi 2020, and volume-only baselines using Mesh Volume alone. Metrics: Harrell's C-index and AUROC with 1,000 stratified bootstrap resamples. We hypothesize that if a signature captures information beyond volume, the negative control would yield much lower performance.
The Aerts survival signature does not notice the destruction of the image. Across all three datasets the result is a flat line: in RADCURE the original signature yields 0.67 C-index and all nine negative controls are within ±0.02 of it, with the volume-only reference running through the middle of the whole set. HN1 behaves identically at 0.63–0.65 with wider distributions (n=137) and LUNG1 has narrow distributions at 0.60–0.62. No control is distinguishable from the original, and none from volume alone.
The Choi HPV status signature carries real image signal outside the tumour. The signature demonstrated improved performance over the volume-only model when applied to original images while perturbations applied to the Full and Background regions resulted in substantial performance degradation, whereas perturbations confined to the ROI had a comparatively smaller effect. This pattern suggests that the predictive signal for HPV status does not come from features within the tumour but rather its peripheries and outside.
FMCIB reads the background. For the foundation model, ROI-based negative controls produced negligible differences in correlation structure relative to the original images (Figure 3.8h,j). However, when perturbations were introduced to the background, the correlations diminished, regardless of whether the ROI was perturbed (Figure 3.8h,j). These features are insensitive to perturbations within the tumour volume and are instead primarily derived from information at the tumour boundary or from surrounding background regions.
Investigating four representative texture features as archetypes and their correlations with tumour volume. Features with stronger volume dependence exhibited consistent relationships with tumour volume across all negative control configurations, with minimal deviation between original and permuted images, as seen with GLRLM Gray Level Non-Uniformity (Figure 3.9e), one of the features included in the Aerts signature Aerts 2014. There are features with weaker volume correlation, like GLCM Cluster Prominence (Figure 3.9b) that remained largely unchanged under spatial perturbation, suggesting limited biological or structural relevance despite apparent independence from volume. Finally, features sensitive to negative control perturbations while maintaining lower correlation with volume, such as GLDM Dependence Variance (Figure 3.9c) represent candidates with potential biological interpretability. Supplementary Table 2 ranks the 20 features most changed by each negative control, and Supplementary Table 3 the ten most changed across all nine. Both are dominated by GLSZM and GLCM texture features computed on filtered images, led by wavelet-HHH GLSZM Small Area High Gray Level Emphasis (first or second under every control).
Predictive performance alone constitutes insufficient evidence of biological validity. Features that remain invariant under spatial perturbation while correlating with tumour volume may not capture intrinsic tumour heterogeneity, irrespective of their discriminative accuracy. Consequently, published radiomic signatures warrant re-evaluation against volume-only baselines rather than acceptance based on discrimination metrics alone. The demonstrated inadequacy of correlation filtering indicates that volume confounding cannot be resolved through post-hoc feature selection and must instead be interrogated directly.
The differential sensitivity of the Choi HPV status signature to full-image and background perturbations, relative to ROI-restricted perturbations, localizes predictive signal to the tumour boundary rather than the intratumoural region, supporting the deliberate modelling of peritumoural context rather than its exclusion. These findings align with emerging evidence supporting the relevance of tumour-stroma interactions Fan 2023 and peritumoural radiomics Sun 2018Zhang 2025 for biologically meaningful prediction tasks. Future works of READII-2-ROQC can compare its additional region types that are already implemented to investigate the peritumoural region including: contraction, contraction ring, expansion, expansion ring, and bi-directional ring.
Role of the candidate: co-author and member of the core development team since 2019. Contributed to conceptualization, data curation, software development and methodology, and to review and editing of the manuscript. The clinical acceptability study was added after the candidate's primary involvement. Med-ImageTools was noted to have contributed 240 of 450 developer-hours saved.
Models. Twelve open-source architectures refactored into PyTorch Lightning under one shared loss (weighted TopK cross-entropy over the hardest 10% of voxels + Focal Tversky), with models excluded based on the following criteria: 2D-only designs not convertible to 3D without breaking architectural integrity, close similarity to an included architecture, unmaintained code, or non-integrability into Lightning. nnU-Net was included in the secondary stage of the study as a separate use case Isensee 2021.
| Dataset | Institution | # | Use in Manuscript | Available Data | ||
|---|---|---|---|---|---|---|
| Imaging | Clinical | OAR | ||||
| RADCURE | UHN | 2552 | Training/Tuning/Internal Testing | ☑️ | ☑️ | ☑️ |
| HNSCC-3DCT-RT | MIAMI | 94 | Generalizability Assessment | ☑️ | ☑️ | ☑️ |
| Deepmind | HMS + Multi-Site | 35 | Generalizability Assessment | ☑️ | ☑️ | |
| PDDCA | HMS | 48 | Generalizability Assessment | ☑️ | ☑️ | |
| Radiomics-HN1 | MAASTRO | 137 | Generalizability Assessment | ☑️ | ☑️ | ☑️ |
| STRUCTSEG19 | CAS | 50 | Generalizability Assessment | ☑️ | ☑️ | |
| Head-Neck-CT-Atlas | MDACC | 215 | Generalizability Assessment | ☑️ | ☑️ | ☑️ |
| SegRap 2023 | UESTC | 120 | Generalizability Assessment | ☑️ | ☑️ | |
| HaN-Seg | SLOVENIA | 42 | Generalizability Assessment | ☑️ | ☑️ | |
Data. Med-ImageTools was used to curate radiotherapy head and neck cancer imaging datasets from 9 different institutions, totalling 3,293 patients. We used RADCURE for training: 582 patients with all 19 essential OARs, split 479/44/59. RADCURE contains 34 distinct OARs, which include all 19 essential structures for RT planning.
Metrics. Dice similarity coefficient (DSC) and 95th-percentile Hausdorff distance (95HD) are used to evaluate all models. The refined model is additionally investigated with surface distance, added path length, false-negative volume/length and Jaccard. Kruskal–Wallis H-tests between models per OAR. Dosimetric evaluation was intentionally excluded to prioritize anatomical accuracy over surrogate measures of dose/volume metric impact.
The top three models were all U-Net variants. WOLNET was selected as it was the only model ranking top-5 for every OAR and top-3 for 16 of 19. Refined WOLNET on the RADCURE held-out set: median DSC 0.82 (95% CI 0.67–0.97), 95HD 2.8mm (-12.0mm to 17.6mm) overall. Comparatively, nnU-Net yielded DSC 0.87 (0.75–0.97), 95HD 2.0mm (-7.7mm to 11.7mm), achieving higher DSC and lower 95HD on all OARs than refined WOLNET on RADCURE. On external datasets, nnU-Net demonstrated higher performance with some outliers, such as acoustic structures.
We evaluated contours generated by refined WOLNET vs manual contours used as ground-truth to train WOLNET. Four expert observers (head-and-neck fellows or staff radiation oncologists with >10 years' experience) were blinded to contour source and reviewed contours in a re-engineered QUANNOTATE web interface with bone/soft-tissue/lung windowing presets, by OAR category rather than by patient on a 5-point Likert scale Kim 2023.
Mean acceptability rating (MAR) of the ground truth scored 3.8 ± 0.9 versus the AI contours’ 3.4 ± 1.0. With a threshold of MAR>3.5 as clinical acceptability, 78% of ground-truth contours were acceptable versus 52% of AI contours. 16 of 19 AI OARs were determined to be clinically acceptable with minor edits. OARs that did not pass the test after revision were larynx (2.38), brainstem (2.80), and chiasm (2.90).
22% of expert manual contours failed the acceptability threshold with ground-truth MAR only 3.8±0.9, and 15 manually delineated OARs on average were considered clinically acceptable, compared to 9 OARs generated by deep learning. This is consistent with Brouwer and colleagues' study that delineated 9 swallowing OARs in 29 patients under five published guidelines and found median concordance with the reference guideline of 0.54 for the pharyngeal constrictors, 0.56 for laryngeal structures and 0.07 for the cricopharyngeal and oesophageal inlet muscles. The resulting variance in mean dose reached 3.5±3.2 Gy and changed the modelled NTCP for dysphagia by more than 10 percentage points in 7% of patients Brouwer 2014. Van Dijk and colleagues observed comparable instability under blinded review. In a Turing-test evaluation across 22 head and neck OARs, raters preferred manual contours overall, and the margin over deep learning was narrower van Dijk 2020.
Geometric rank and clinical acceptability ranks diverge. The optic chiasm had the worst DSC (0.38) and worst 95HD (9.6mm) of any structure, yet its AI acceptability was statistically indistinguishable from its own ground truth (2.90 vs 3.03). The larynx was the least acceptable AI structure (2.38) despite a respectable DSC of 0.88 on RADCURE. Our results build on a common pitfall noted by the Metrics Reloaded consensus that smaller structures tend to receive lower DSC scores even with small deviations, complicating cross-OAR comparisons with the effect being larger for DSC than 95HD Reinke 2024. Given that clinical acceptability testing was performed by only four radiation oncologists, statistical power of our conclusions is limited. Future studies can invite broader clinician participation for a robust conclusion.
Let’s reconsider the two questions at the start of the chapter.
Is the signal real, or is it size? Prognostic performance in the challenge was driven by EMR features and volume, with engineered radiomics correlating with volume at ρ=0.79–0.85. In Deep-CR-MTLR, the image arm added as much to the prediction of other-cause death as to cancer death, and its gain was never tested against volume. A published radiomic survival signature survived the destruction of image content across all nine negative controls, an HPV-status signature drew its signal from the tumour periphery, and a foundation model’s features derived from the background rather than the tumour.
Does a good metric mean a usable model? SCARF demonstrated that good geometric performance does not guarantee clinical acceptability and the experts' own contours fail peer review 22% of the time.
However, volume-independent imaging signal is learnable and must be demonstrated rather than assumed. The RADCURE-challenge model 9 achieved ρ=0.22 with AUROC 0.766, and READII’s perturbation-sensitive, volume-independent feature archetype exists. To increase the chances of clinical adoption, a model must be well characterized through volume correlation analysis, external validation, negative-control or ablation evidence, expert-anchored evaluation, and an operating point tied to a clinical decision.
The next chapter presents a model built with these specifications. Each design decision is traceable to a finding from this chapter: the patient-level target and radiologist supervision, the absence of any node-segmentation dependency (Ch.3.5), the explicit volume-correlation analysis (Ch.3.2 and 3.4), external validation under case-mix shift (Ch.3.2.4), and characterizing the model’s operating thresholds to a specific clinical decision (Ch.1.3).
HypothesisA patient-level model can exceed volume and clinical baselines and stratify outcomes comparably to a clinician.
Kim S, Huang SH, Bartlett E, Yu E, Hoebers F, Postma AA, Palm WM, McIntosh C, Bratman S, Waldron J, O'Sullivan B, Haibe-Kains B*, Hope A*
Extranodal extension (ENE), defined as the growth of metastatic disease in lymph nodes through lymph-nodal capsule into surrounding soft tissue, has been identified as a major negative prognostic factor for head and neck squamous cell carcinoma (HNSCC) and is associated with the risk of progression and distant metastasis Huang 2020. ENE was incorporated into the 8th edition of the UICC/AJCC staging criteria (TNM) for non-viral HNSCC and is now also included in the 9th edition TNM for HPV associated (HPV+) oropharyngeal carcinoma Huang 2025Brierley 2025Brierley 2026. While pathologic indication of ENE (pENE) is the gold-standard of determining ENE, pENE is not available in non-surgically treated patients, which accounts for the majority of HNSCC, nor is it available before the initial treatment decision has been made Schlichting 2019Zheng 2025.
Imaging ENE (iENE) has emerged as a novel prognostic factor independently associated with oncologic outcomes and a detailed radiologic criteria system has been developed and validated for radiology use Huang 2020Henson 2024. Huang and colleagues demonstrated that staging schemas incorporating imaging-based ENE (iENE) show significant improvements compared to TNM in discriminating high-risk and low-risk patients for overall survival, disease-free survival and distant control Huang 2020. This is especially consequential in oropharyngeal carcinoma, where treatment intensity is driven by the presence of iENE Ferris 2022.
Accurately labeling iENE requires substantial expert radiologist training. Sahin and colleagues have demonstrated that precise iENE determination is a difficult task, with high interobserver variability and low diagnostic accuracy without substantial training Sahin 2025. This motivates an automated approach to make consistent iENE determinations. Deep-learning screening systems have been shown to recapitulate radiologist-level expertise in chest radiography and computer-aided diagnostic settings Tavaziva 2022Yacoub 2022. Prior AI work on ENE has predicted pathologic ENE of individual lymph nodes rather than patient-level iENE Kann 2018Kann 2020Ye 2026. Dayan and colleagues recently reported an automated pipeline that segments involved lymph nodes on treatment-planning CT and classifies the iENE status of the largest node Dayan 2026. Similarly, our model is trained on radiation treatment-planning CT rather than diagnostic CT, allowing it to be deployed directly within the radiotherapy workflow on imaging routinely acquired for every patient.
We present a patient-level deep learning model that predicts radiology-defined iENE from treatment planning CT scans, trained directly on radiologist-determined iENE labels rather than pathologic ENE. The model is designed for operational deployment: it requires no manual lymph node segmentation, operating end-to-end through an automated larynx localization step that defines the input crop, and produces a single patient-level prediction interpretable on the same scale as the radiologist's clinical determination. We train and internally validate the model on the publicly accessible RADCURE cohort Welch 2024 and externally validate on an independent external cohort from Maastro Clinic. The full training and inference pipelines, trained model weights, and reproducible software environment are released as open-source resources to enable downstream validation and adoption.
Datasets/Experimental Setup. We leverage three public head and neck cancer datasets with RT planning CT images to train all models in this study: “RADCURE”, “HNSCC”, and “HEAD-NECK-RADIOMICS-HN1” Welch 2024Grossberg 2018Wee 2019. The “HNSCC” and “HEAD-NECK-RADIOMICS-HN1” datasets used to train the nnU-Net larynx segmentation model were processed using Med-ImageTools Kim 2025, filtering ROI names found in each sample’s DICOM RTSTRUCT and saving the underlying image and larynx segmentation mask into NIfTI format. Med-ImageTools’ AutoPipeline feature handles all DICOM handling, processing logic, and image operations. RADCURE was excluded from the training set for the larynx segmentation model to remove any training biases of locating the larynx.
The RADCURE dataset is a large dataset of HNSCC patients between 2005-2017 and their images and contours collected clinically during RT planning. A subset of 915 patients with newly diagnosed primary OPC and radiologist-determined iENE labels was included in this study. The dataset was split as close to 80/20 based on diagnosis date to simulate a pseudo-prospective trial, resulting in a training set of 752 patients and a held-out set of 163 patients. An additional dataset from the Maastro clinic at Maastricht, Netherlands is used for external validation of the iENE model. The dataset is composed of 175 OPC patients and their treatment planning CT.
iENE Label Determination. iENE labels in RADCURE were retrospectively determined by a single experienced head and neck radiologist from the radiotherapy planning CT. The radiologist’s determinations were made prior to any formalization of criteria by consensus groups, but followed closely to the ASHNR criteria, considering iENE positive only when there were unequivocal imaging findings. iENE labels in the Maastro cohort were also assessed retrospectively by two neuroradiologists, using the modality with the highest diagnostic quality available at staging (Diagnostic MRI, Diagnostic CT, Planning PET-CT), based on previously established diagnostic criteria Hoebers 2022. Only the CT scan of the planning PET-CT was used to determine iENE.
Image Preprocessing. CT volumes were resampled to 1mm isotropic XY spacing. Intensity values were windowed to [-500, 1000] and normalized to [0, 1]. The predicted larynx mask from the nnU-Net was used to compute a centroid, which defined the center of a 256 × 256 × 128 voxel crop fed to the iENE model. No additional contrast or artifact correction was applied.
Baseline Comparison Models. Three baseline models were trained against the same training/test split as the deep learning model to contextualize performance: (1) a clinical model using T category, N category, HPV/p16 status, age, sex, and smoking history; (2) a volume model using the volume (mm3) and largest diameter of the largest nodal gross tumour volume (GTVn); and (3) a mixed clinical + volume model using features from both models. Each baseline was a logistic regression model with L2 regularization, fit separately within each of the four cross-validation training folds. Categorical variables were one-hot encoded; continuous variables were standardized using training-set means and standard deviations. Predictions on the held-out test set and external Maastro cohort were averaged across the four cross-validation folds, matching the deep learning ensemble.
Patient-level iENE Model Training. The iENE model is built on the ResNet18 architecture He 2016 with ACS convolutions Yang 2021, initialized with ImageNet pretrained weights Deng 2009. The ResNet18 architecture with ACS convolutions was selected to balance feature extraction capabilities with computational efficiency, ensuring the model remains lightweight enough for rapid clinical deployment and inference in resource-constrained hospital environments. The model input is a treatment planning CT centered around the larynx, cropped to voxel dimensions of 256x256x128, with 1mm isotropic spacing on the XY plane and original slice thickness of the acquisition. The training set was split into 4-folds for cross-validation and to train separate models on each data split, serving as biological replicates. Each model was initially trained for 150 epochs with a batch size of 16, data augmentation of random rotation, dropout of 0.4, a learning rate of 10-3 with the Adam optimizer with weight decay, using the binary cross-entropy loss function with class imbalance weight of 4.48 applied to iENE-positive cases Kingma 2015. For each fold, we conducted triplicate training runs of the model, serving as technical replicates. The best performing checkpoint was selected based on the sum of the AUROC and AUPRC on the fine-tuning portion of each fold. A subsequent fine-tuning run of 100 epochs was performed for each model replicate with a lower learning rate, and the best model checkpoint across all technical replicates within each fold was selected based on the same aforementioned metrics. This checkpoint is saved as the final model for each fold, resulting in four trained models total.
iENE Model Inference. All code and model weights used to perform inference of iENE is available on GitHub: https://github.com/skim2257/iENE_infer/. Inference of iENE on unseen data occurs in two steps: larynx segmentation and iENE inference. The nnU-Net larynx segmentation model requires the medical images to be in NIfTI format. An optional step of processing raw DICOM images to NIfTI format can be performed via Med-ImageTools, which is executable via pixi, as configured in the ‘iENE_infer’ repository Kim 2025. The larynx segmentation model inference is performed using the nnU-Net’s default settings, and the predicted masks are saved in a user-specified output directory. The predicted larynx is used to define the bounding box used to crop the model input for the iENE model Isensee 2021. We employ test-time augmentation (TTA) to add minor variances to the model input, providing insights about model uncertainties and improving predictive accuracy Ayhan 2018Shanmugam 2021. Six translations, 12 voxels in both directions for each of the three axes, are applied to each image, yielding a total of seven inferences per image. Since inferences are generated with TTA for each of the four models, each sample will have 28 predicted probabilities of iENE. While there are a variety of ways to aggregate multiple predictions into a final probability of iENE, we take the simple average of 28 predictions, as we do not have extensive held-out testing data to calibrate or meta-learn the weighted importances of each “configuration” of predictions.
Statistical Analysis. Where a binary determination was required, a patient was declared model-iENE-positive when this probability was at or above a decision threshold τ. The primary threshold, τ = 0.5, is the conventional decision boundary for a classifier trained with binary cross-entropy. We examined additional thresholds, at τ = 0.25 as sensitivity-favoring, screening operating point and τ = 0.75 as specificity-favoring, staging operating point. For our statistical analyses, the same thresholds were uniformly applied to both cohorts without recalibration. Because predicted probabilities were not recalibrated to each cohort’s iENE prevalence, a given threshold does not correspond to a fixed sensitivity or specificity across cohorts. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated at each threshold in both cohorts, with Wilson 95% CIs (Table 4.6).
Because ENE is more frequent in larger lymph nodes, an image-based model could achieve high discrimination by learning nodal size alone. To characterize the extent to which the model’s output reflects nodal size, we computed Pearson and Spearman correlations between the predicted probability and the volume of the patient’s largest nodal gross tumour volume (GTVn) on the RADCURE held-out set. GTVn volumes were derived from the clinical treatment-planning contours, which were used only for this analysis and for the volume baseline and are not required by the model.
Survival was estimated with the Kaplan-Meier method and compared between groups with the log-rank test. 95% CIs for AUROC and AUPRC were estimated with 100 bootstrap resamples of patients. Differences in AUROC and AUPRC were estimated on the RADCURE held-out set with a paired bootstrap of 2,000 draws, in which each draw scores all models on the same resample, since two models tested on the same patients need a paired comparison DeLong 1988. For each of the six pairwise comparisons among the deep learning model and the three baselines, we report the difference, its 95% bootstrap interval and a two-sided p-value (Supp.Table 4). Unadjusted hazard ratios (HRs) with 95% CIs for distant control were estimated with separate univariable Cox proportional hazards models for the radiologist’s determination and for the model’s prediction at each threshold. The same models were fitted for the volume baseline thresholded at the same values of τ (Supp.Table 5).
Negative control ablation analysis. A correlation with volume describes an association and does not show which part of the image the model reads. We therefore applied the READII-2-ROQC negative controls (Ch.3.4) to the trained model, with two definitions of the region of interest analysed separately: the patient’s largest GTVn and the primary gross tumour volume (GTVp). GTVp is contoured tumour in the same image but is not where iENE is assessed, so a response that is specific to the node should not appear when primary tumour is perturbed. Three permutations (Shuffle, Sample and Random) were each applied to three regions: the ROI, the image outside the ROI (non-ROI, the Background region of Ch.3.4) and the full image, giving nine perturbed copies of each planning CT in the RADCURE held-out set for each ROI definition. Patients without GTVp or GTVn contours were excluded from both analyses, so that the two sets of controls are compared on the same patients (n=142). The negative controls were passed through the same inference pipeline as the originals and each control’s AUROC was calculated against the radiologist’s determination, the Pearson correlation between predictions on the original and control images, and the standard deviation of the per-patient residual, defined as the original minus the control prediction (Figure 4.3, Supp.Table 6). Following Chapter 3.4, we hypothesized that if the model’s output depends on image content beyond nodal size, a control that destroys that content will lower discrimination, and that the region in which perturbation causes the loss indicates where the signal lies.
Error profiling. To examine where the model fails in an external cohort, we compared the two cohorts across their clinical characteristics and acquisition geometry with Mann-Whitney, chi-square or Fisher exact tests and standardized differences (Supp.Table 7). Within the Maastro cohort, AUROC with 95% CIs from 2000 stratified bootstrap resamples and error rates at τ=0.50 were estimated by subgroup (Supp. Table 8, Supp. Figure 3). False negatives and false positives were each tested against label modality and the same clinical/acquisition factors, with the aforementioned tests and logistic regression (Supp. Table 9). Whether a factor changed the relation between score and label was tested with a likelihood-ratio test of the interaction between the model’s probability output and the clinical/acquisition factor. P-values were adjusted by the Benjamini-Hochberg method and are reported as q. It is important to note that these post-hoc analyses are not meant to be new findings, but are exploratory.
Calibration and decision curve analysis. Calibration was assessed in both cohorts with a logistic calibration model, reporting the calibration slope, intercept and calibration in-the-large with Wald 95% CIs, the Brier score, and a grouped calibration error over eight quantile groups of the predicted probability Van Calster 2019. Clinical utility was assessed by decision curve analysis with distant failure within 2 years as the outcome Vickers 2006. Each strategy selects a group of patients to treat as high risk: the radiologist’s iENE determination, the model’s determination at τ = 0.25, 0.50 and 0.75, and the volume baseline at the same thresholds in the RADCURE held-out set. They were compared with treating all patients as high risk (treat all) and none (treat none). Net benefit weighs the selected patients who develop distant failure against those who do not, at the exchange rate implied by the threshold probability, which is the 2-year risk of distant failure at which a clinician would act. The 2-year risk in each selected group was estimated by the Kaplan-Meier method Vickers 2008. Threshold probabilities ran from 0.01 to 0.30, net benefit is tabulated at 0.10, and 95% CIs are percentile intervals from 2000 stratified bootstrap resamples. Because each strategy is a fixed rule, the analysis does not treat the model’s score as a probability and is reported for both cohorts.
We developed a patient-level deep learning model that predicts radiologist-determined iENE directly from treatment-planning CT, requiring no manual lymph node segmentation. The model was trained and internally validated pseudo-prospectively on the RADCURE cohort by splitting based on diagnosis date and externally validated on the independent Maastro cohort. Cohort characteristics are summarized in Table 4.1 Welch 2024.
| RADCURE | Maastro | |||
|---|---|---|---|---|
| Training n=752 | Test n=163 | Total n=915 | External n=175 | |
Sex Female Male | 130 (17.3%) 622 (82.7%) | 42 (25.8%) 121 (74.2%) | 172 (18.8%) 743 (81.2%) | 44 (25.1%) 131 (74.9%) |
Median age in years (IQR) | 60 (54-68) | 63 (56-70) | 61 (54-68) | 62 (56-68) |
Smoking history ≥10 pack-years <10 pack-years | 460 (61.2%) 292 (38.8%) | 103 (63.2%) 60 (36.8%) | 563 (61.5%) 352 (38.5%) | 128 (73.1%) 47 (26.9%) |
HPV/p16 status Negative Positive Unknown | 202 (26.9%) 536 (71.3%) 14 (1.9%) | 52 (31.9%) 109 (66.9%) 2 (1.2%) | 254 (27.8%) 645 (70.5%) 16 (1.7%) | 74 (42.3%) 101 (57.7%) 0 (0.0%) |
T category (UICC/AJCC 8th) T0 T1 T2 T3 T4+ | 1 (0.1%) 130 (17.3%) 279 (37.2%) 208 (27.5%) 134 (17.8%) | 0 (0.0%) 33 (20.2%) 48 (29.4%) 48 (29.4%) 34 (20.8%) | 1 (0.1%) 163 (17.8%) 327 (35.7%) 256 (28.0%) 168 (18.3%) | 0 (0.0%) 28 (16.0%) 48 (27.4%) 35 (20.0%) 64 (36.6%) |
N category (UICC/AJCC 8th) N0 N1 N2 N3 | 118 (15.7%) 56 (7.4%) 529 (70.3%) 49 (6.5%) | 28 (17.2%) 22 (13.5%) 107 (65.6%) 6 (3.7%) | 146 (16.0%) 78 (8.5%) 636 (69.5%) 55 (6.0%) | 0 (0.0%) 93 (53.1%) 78 (44.6%) 4 (2.3%) |
Overall stage I II III IV | 377 (50.1%) 159 (21.1%) 79 (10.5%) 137 (18.2%) | 80 (49.1%) 30 (18.4%) 17 (10.4%) 36 (22.1%) | 457 (49.9%) 189 (20.7%) 96 (10.5%) 173 (18.9%) | 43 (24.6%) 24 (13.7%) 45 (25.7%) 63 (36.0%) |
Median follow-up time in days (IQR) | 1646 (958-2148) | 959 (618-1120) | 1444 (854-2030) | 1620 (904-2488) |
Treatment type RT RT+Chemo RT+EGFRI | 332 (44.2%) 386 (51.3%) 34 (4.5%) | 78 (47.8%) 81 (49.7%) 4 (2.5%) | 410 (44.8%) 467 (51.0%) 38 (4.2%) | 59 (33.7%) 116 (66.3%) 0 (0.0%) |
Contrast enhanced Yes No | 556 (73.9%) 196 (26.1%) | 140 (85.9%) 23 (14.1%) | 696 (76.1%) 219 (23.9%) | Not available |
Slice Thickness (min-max, mean in mm) | 2.0-2.5 (2.10) | 2.0-2.5 (2.04) | 2.0-2.5 (2.09) | 3.0 (3.0) |
iENE Yes No | 142 (18.9%) 610 (81.1%) | 25 (15.3%) 138 (84.7%) | 167 (18.3%) 748 (81.7%) | 60 (34.3%) 115 (65.7%) |
The final iENE model is a ResNet18 architecture with ACS convolutions, trained across 4 folds of the 752-patient training dataset He 2016Yang 2021. To account for technical variability, we trained 3 technical replicates on each fold for 150 epochs and selected the best checkpoint by the sum of AUROC and AUPRC on the fine-tuning portion of each fold. The selected checkpoints were finetuned for an additional 100 epochs. The best fine-tuned checkpoint per fold was chosen to compose the final ensemble and calculate the following results.
| Model | AUROC | AUPRC |
|---|---|---|
| Deep Learning | 0.913 [0.852–0.961] | 0.603 [0.470–0.817] |
| Mixed | 0.786 [0.685–0.878] | 0.474 [0.338–0.686] |
| Volume | 0.851 [0.773–0.921] | 0.498 [0.373–0.713] |
| Clinical | 0.681 [0.575–0.782] | 0.322 [0.214–0.495] |
On the RADCURE held-out test set, the deep learning model had the highest point estimates for AUROC (0.913) and AUPRC (0.603), followed by volume baseline (0.851 and 0.498; Figure 4.1, Table 4.2). In paired bootstrap comparisons on the same patients, our model’s AUROC was higher than that of clinical and mixed baselines (Supp. Table 4). The difference from the volume baseline was smaller and its confidence interval included zero (+0.062 [–0.004 to +0.134], p=0.067). The deep learning’s AUPRC tells a similar story, but was not distinguishable from the volume baseline (+0.105 [–0.109 to +0.302], p=0.334). The volume baseline was itself higher than the clinical and mixed baseline on AUROC and only the clinical baseline on AUPRC. The deep learning model’s AUPRC was approximately four times the random-classifier baseline of 0.153.
Because larger nodes are more likely to harbor ENE, we next assessed whether the model acts as a surrogate for nodal size. The model’s output correlates moderately with the volume of the patient’s largest locoregional lymph node (GTVn), with Pearson r=0.335 and Spearman ρ=0.587 (Figure 4.2). Although statistically significant, this association leaves most of the variation in model output unexplained by volume.
It is also important to consider the model’s performance on ambiguous samples, by observing outliers. The scatterplot shows expected false positives at larger GTVn volumes, and false negatives with smaller GTVn volumes, but the model also confidently rejects several cases with extremely large GTVn volumes, avoiding false positives that a volume-based model would not reject, demonstrating that the model integrates signal beyond size (Figure 4.2).
The READII-2-ROQC negative controls helped locate the relevant image content behind the model’s predictions (Figure 4.3, Supp. Table 6). On the original images, the AUROC was 0.908, and shuffling or resampling GTVp left the model’s output essentially unchanged from the original whereas the same controls applied to the largest GTVn moved individual predictions further. Replacing the ROI with uniform random intensities further lowers the AUROC, down to 0.865 for the largest GTVn (p=0.025). Individual predictions moved further when the node was replaced (r=0.793; residual SD 0.172) than when the primary tumour was (r=0.966; residual SD 0.071). Perturbations outside the ROI entirely removed any prediction power for both GTVn and GTVp, whether the ROI was left intact (non-ROI) or perturbed as well (full). An intact largest node was therefore not sufficient for the model to find any meaningful insights, and neither was an intact primary tumour.
Performance of the model on the external validation set was stratified by the image modality used to clinically determine iENE (Figure 4.4, Table 4.3). The model performs best and most consistently on labels determined by CT or MRI, and moderately on PET-CT-determined labels. We note that the CT-labeled subset is small (n=21), and the AUROC and AUPRC estimates on this subset carry wide uncertainty; bootstrap confidence intervals are reported in Table 4.3 to quantify this. Modality-stratified performance should therefore be interpreted as indicative rather than definitive, with the aggregate evaluation across the full Maastro cohort (n=175) providing the most stable estimate of the model's external generalization.
| Modality | n (ENE+) | AUROC | AUPRC |
|---|---|---|---|
| Overall | 175 (60) | 0.671 [0.579–0.763] | 0.602 [0.498–0.719] |
| CT | 21 (8) | 0.769 [0.538–0.952] | 0.735 [0.523–0.934] |
| PET-CT | 79 (28) | 0.571 [0.422–0.717] | 0.587 [0.454–0.732] |
| MRI | 75 (24) | 0.749 [0.627–0.864] | 0.598 [0.461–0.794] |
Compared with RADCURE, the Maastro cohort differed more in acquisition geometry than in clinical characteristics (Supp.Table 7). At τ=0.50 the model had 23 false-negatives and 33 false positives. Of the factors examined, the reconstructed axial field of view (FOV), which sets the in-plane pixel spacing, had the strongest association with both kinds of error (Supp.Tables 8–9, Supp.Fig 3). In the 68 scans reconstructed above 500mm, the model missed 17 of 24 iENE-positive (71%), against 6 of 36 at 500mm or less (17%, q<0.001), and wrongly flagged 5 of 44 iENE-negative patients (11%), against 28 of 71 (39%, q=0.006). FOV also changed the relation between score and label (p=0.003, q=0.013 from Supp.Table 9).
Label modality was associated with more false negatives (q=0.049), but the likelihood-ratio test of the score-by-modality interaction was not significant after adjustment (p=0.028, q=0.056). The two factors were related, since 38 of the 79 PET-CT labels were scanned above 500mm (AUROC 0.511) against 30 of the other 96, and AUROC fell only where they coincided (AUROC 0.779 in PET-CT, 500mm or less from Supp.Table 8).
To assess the prognostic value of the model’s outputs, we evaluate Kaplan-Meier (KM) survival curves using simulated deployment data at specific thresholds. Distant control was selected as the endpoint of interest because ENE is mechanistically and clinically linked to distant metastatic spread rather than to local failure, and because overall survival in this predominantly HPV-positive, favorable-prognosis population is diluted by competing causes of death and by long survival times that limit event counts within available follow-up Huang 2020. While the two sets of predictions are not fully independent from each other since the model was trained using the clinician’s determination as ground truth, this analysis serves as a sanity check to understand whether the model recapitulates the training labels or captures independent prognostic signals. Using the primary decision threshold of τ=0.5 to visualize distant control outcomes, on the RADCURE held-out set (Figure 4.5a), the model’s predictions separated high and low-risk groups (p<4.0-9), as did the radiologist’s determination (p<1.49-7). Separation remained significant in the external validation set across all labeling modalities (p<2.46-4).
| RADCURE HPV+ (n=109) | τ=0.25 (n=30) | τ=0.50 (n=17) | Maastro HPV+ (n=101) | τ=0.25 (n=67) | τ=0.50 (n=40) | |||
|---|---|---|---|---|---|---|---|---|
| iENE+ | 15 (13.8%) | 12 (40.0%) | 9 (52.9%) | 37 (36.6%) | 28 (41.8%) | 21 (52.5%) | ||
| iENE– | 94 (86.2%) | 18 (60.0%) | 8 (47.1%) | 64 (63.4%) | 39 (58.2%) | 19 (47.5%) |
To explore prognostic separation across a range of operating points, we evaluate Kaplan-Meier survival curves for distant control at multiple decision thresholds (τ > [0.25, 0.50, 0.75]), simulating deployment configurations that trade sensitivity against specificity. Across all patients (Figure 4.6), higher thresholds yield more conservative, higher-specificity iENE declarations, while lower thresholds flag a larger proportion of patients for radiologist review.
| iENE Label Source | HR (95% CI) | |
|---|---|---|
| RADCURE (n=163) | Maastro (n=175) | |
| Radiologist | 7.03 (3.03–16.35) | 2.94 (1.38–6.30) |
| τ = 0.25 | 5.07 (2.16–11.87) | 1.82 (0.73–4.51) |
| τ = 0.50 | 8.30 (3.58–19.25) | 4.15 (1.82–9.49) |
| τ = 0.75 | *6.29 (2.58–15.35) | 8.04 (2.99–21.59) |
In unadjusted Cox models (Table 4.5), model-defined iENE was associated with worse distant control at every threshold in the RADCURE held-out set and τ > [0.50, 0.75] in the Maastro cohort, which held similar to the radiologists’ determinations. Thresholding the volume baseline at the same values gave hazard ratios of 4.56 (95% CI 1.83–11.37), 2.99 (0.69–12.93) and 1.62 (0.22–12.13) at τ = 0.25, 0.50 and 0.75 in the RADCURE held-out set (Supp.Table 5). These intervals included 1 at τ = 0.50 and 0.75 and overlapped those of the deep learning model at every threshold. Separation was consistent in early and late-stage disease (Supp.Figure 1) and was also examined by HPV/p16 status (Figure 4.7, Table 4.4) and jointly by HPV status and stage (Supp.Figure 2), which isolates the HPV-positive early-stage subgroup most relevant to the E3311 trial design.
The operating characteristics of the three thresholds are given in Table 4.6. In the RADCURE held-out set, τ=0.25 flagged 40 of 163 (24.5%) and identified 21 of 25 iENE-positive patients. At τ=0.75, the model called 12 patients positive, of whom 8 were iENE-positive. The same thresholds behaved differently in the Maastro cohort. At τ=0.25 the model flagged 118 of 175 patients (67.4%) and identified 46 of 60 iENE-positive patients. At τ=0.75 it called 8 patients positive, of whom 6 were iENE-positive.
| τ | Sensitivity | Specificity | PPV | NPV | TP / FP / TN / FN |
|---|---|---|---|---|---|
| RADCURE held-out set (n=163; 25 iENE-positive) | |||||
| 0.25 | 0.84 (0.65–0.94) | 0.86 (0.79–0.91) | 0.53 (0.37–0.67) | 0.97 (0.92–0.99) | 21 / 19 / 119 / 4 |
| 0.50 | 0.60 (0.41–0.77) | 0.93 (0.88–0.97) | 0.63 (0.43–0.79) | 0.93 (0.87–0.96) | 15 / 9 / 129 / 10 |
| 0.75 | 0.32 (0.17–0.52) | 0.97 (0.93–0.99) | 0.67 (0.39–0.86) | 0.89 (0.83–0.93) | 8 / 4 / 134 / 17 |
| Maastro external cohort (n=175; 60 iENE-positive) | |||||
| 0.25 | 0.77 (0.65–0.86) | 0.37 (0.29–0.47) | 0.39 (0.31–0.48) | 0.75 (0.63–0.85) | 46 / 72 / 43 / 14 |
| 0.50 | 0.62 (0.49–0.73) | 0.71 (0.62–0.79) | 0.53 (0.41–0.64) | 0.78 (0.69–0.85) | 37 / 33 / 82 / 23 |
| 0.75 | 0.10 (0.05–0.20) | 0.98 (0.94–1.00) | 0.75 (0.41–0.93) | 0.68 (0.60–0.74) | 6 / 2 / 113 / 54 |
Calibration differed between the cohorts (Figure 4.8, Table 4.7). In the RADCURE held-out set the mean predicted probability was 0.176 against an iENE prevalence of 0.153 with a Brier score of 0.083 against 0.130 for a constant prediction at the prevalence. In the Maastro cohort the calibration slope was 0.33 (95% CI 0.11–0.55), an interval that excludes 1, indicating the predicted probabilities were too extreme. iENE was more frequent than predicted among low-scoring patients and less frequent than predicted across most of the upper range. The mean predicted probability was 0.397 against an iENE prevalence of 0.343 with a Brier score of 0.226, which was no better than 0.225 of a constant prediction at the prevalence. The group calibration error for the RADCURE held-out set was at 0.048 against 0.168 for the Maastro cohort.
| RADCURE held-out set (n=163) | Maastro external cohort (n=175) | |
|---|---|---|
| iENE prevalence | 0.153 | 0.343 |
| Mean predicted probability | 0.176 | 0.397 |
| Brier score | 0.083 | 0.226 |
| Reference Brier score (prevalence only) | 0.130 | 0.225 |
| Scaled Brier score | 0.364 | −0.004 |
| Calibration-in-the-large (95% CI) | −0.30 (−0.87 to 0.28) | −0.31 (−0.67 to 0.05) |
| Calibration slope (95% CI) | 0.91 (0.59 to 1.22) | 0.33 (0.11 to 0.55) |
| Calibration intercept (95% CI) | −0.36 (−0.95 to 0.23) | −0.47 (−0.81 to −0.14) |
| Grouped calibration error (maximum) | 0.048 (0.147) | 0.168 (0.280) |
Decision curves of 2-year distant failure are shown in Figure 4.9 and net benefit at a threshold probability of 0.10 is on Table 4.8. The 2-year risk of distant failure was 0.134 in the RADCURE held-out set and 0.120 in the Maastro cohort, and treating all patients as high risk has no net benefit at threshold probabilities above these values. In the RADCURE held-out set the 24 patients called positive by the model at τ=0.50 had a 2-year risk of 0.50, against 0.47 for the 25 patients the radiologist called iENE-positive, and net benefit at a threshold probability of 0.10 was 0.065 and 0.063, respectively. At τ=0.25 the model selected more patients at a lower risk (40 patients, 0.34) for a similar net benefit at 0.10 (0.065), which fell below that of τ=0.50. At τ=0.75 it selected 12 patients at a risk of 0.61, with a lower net benefit (0.042). Treating all patients gave 0.037 and the volume baseline at τ=0.50 selected 8 patients at a risk of 0.31 for a net benefit of 0.012. In the Maastro cohort the model at τ=0.50 selected 70 patients at a 2-year risk of 0.23 against 0.24 for the 60 radiologist-positive patients, and net benefit was 0.056 and 0.052, respectively. At τ=0.25 and τ=0.75, the model selected 118 and 8 of 175 patients at a risk of 0.13 and 0.60, for similar net benefit (0.025 and 0.025) as treating all patients (0.022).
| Strategy | RADCURE held-out set (n=163) | Maastro external cohort (n=175) | ||||
|---|---|---|---|---|---|---|
| Selected | 2-year risk | Net benefit (95% CI) | Selected | 2-year risk | Net benefit (95% CI) | |
| Radiologist | 25 | 0.47 | 0.063 (0.031 to 0.093) | 60 | 0.24 | 0.052 (0.019 to 0.087) |
| Model, τ = 0.25 | 40 | 0.34 | 0.066 (0.034 to 0.096) | 118 | 0.13 | 0.025 (−0.009 to 0.060) |
| Model, τ = 0.50 | 24 | 0.50 | 0.065 (0.034 to 0.097) | 70 | 0.23 | 0.056 (0.021 to 0.089) |
| Model, τ = 0.75 | 12 | 0.61 | 0.042 (0.015 to 0.072) | 8 | 0.60 | 0.025 (0.003 to 0.055) |
| Volume, τ = 0.50 | 8 | 0.31 | 0.012 (−0.005 to 0.037) | – | – | – |
| Treat all | 163 | 0.134 | 0.037 (0.015 to 0.056) | 175 | 0.120 | 0.022 (−0.009 to 0.051) |
| Treat none | 0 | – | 0 | 0 | – | 0 |
Reliable determination of iENE is crucial to effective HNSCC staging. Clinically overt ENE was incorporated into the 8th edition UICC/AJCC criteria for non-viral HNSCC but was explicitly not a staging factor for HPV-positive oropharyngeal carcinoma O'Sullivan 2017. It is not equivalent to iENE, a radiologic determination that captures earlier extranodal spread, such as perinodal fat infiltration or nodal coalescence, which would not meet clinical criteria Henson 2024. Unequivocal iENE is now incorporated into the 9th edition clinical N classification for HPV-associated oropharyngeal carcinoma, yet it remains difficult to determine consistently Huang 2025Brierley 2025Brierley 2026Sahin 2025. Pathologic ENE is unavailable in the majority of patients treated non-surgically and cannot inform the initial treatment decision, while radiologic iENE requires substantial expert training and is subject to meaningful interobserver variability Sahin 2025. In this study we developed a deep learning model that addresses this gap in three ways. First, it predicts iENE at the patient level and is trained directly on radiologist-determined iENE labels rather than pathologic ENE, so its output is interpretable on the same scale as the clinical determination it is intended to support. Second, it operates on radiation treatment-planning CT, imaging that is already routinely acquired for every patient, allowing direct deployment within the radiotherapy workflow without additional imaging or manual lymph node segmentation. Third, the full pipeline, trained weights, and software environment are released as open-source, reproducible resources. Together these choices distinguish our approach from prior AI-based ENE work and make the model clinically applicable as defined in chapter 1.12.
Our approach differs from prior AI-based ENE work in both the prediction target and the supervision signal, with implications for clinical interpretability and downstream utility. Kann and colleagues' original work, and the subsequent AI-ENE extension by Ye and colleagues, predict ENE at the level of individual lymph nodes using an auto-segmentation pipeline to enable end-to-end inference Kann 2018Kann 2020Ye 2026. Dayan and colleagues sit between these approaches, supervising on radiologist-determined iENE, but still classifying from a segmented lymph node, in a single-centre HPV-positive cohort without external validation Dayan 2026. Because these node-level models are trained with pENE as ground truth, they learn from a surgically treated population that is non-representative of the broader HNSCC cohort, much of which is treated non-surgically. Patient-level aggregation reported by Ye and colleagues yields at least one AI-ENE-positive node in 70.8% of cases, roughly four times the 15–20% iENE prevalence reported in radiologic series including our own, suggesting a model that is highly sensitive but not tuned to a clinically actionable specificity Huang 2020Ye 2026. Without an iENE ground truth to anchor the patient-level aggregation, AI-ENE outputs cannot be directly compared to a radiologist's determination and are difficult to integrate into staging frameworks such as the 9th edition TNM, which is defined relative to iENE rather than pENE or AI-ENE Huang 2025O'Sullivan 2020.
In contrast, our model is anchored to radiologist-determined iENE and retained above-chance discrimination on both the internal held-out and external validation sets, albeit with a substantial drop externally. The Kaplan-Meier analyses indicate that its stratification of high- and low-risk patients is comparable with that of the radiologist's determination on which it was trained. The hazard-ratio intervals of the two overlapped at every threshold in both cohorts (Table 4.5), and the comparison is not a formal test of equivalence. This separation, however, primarily reflects specificity at the chosen operating point and does not directly characterize sensitivity, which must be assessed separately when considering deployment (Table 4.6). Future work could examine whether combining the two paradigms, by using a sensitive node-level model to flag candidate locoregional nodes and a specific patient-level model to confirm clinically meaningful iENE, could outperform either approach alone, particularly for isolating high-risk subpopulations within HPV-positive disease.
Nodal volume alone was a strong predictor of iENE (AUROC 0.851), and our data do not show that the deep learning model outperforms it. The model’s point estimates were higher on both AUROC and AUPRC, but the paired differences were not distinguishable from zero (Supp.Table 4). With only 25 iENE-positive patients in the held-out test set, the comparison was underpowered and is inconclusive rather than evidence of equivalence. The interval for the AUROC difference is compatible with no difference and with an advantage of up to 0.13 for the deep learning model. Larger, multi-institutional test sets and prospective validation are needed to resolve it. In practice, a volume model requires a clinician-drawn nodal contour, whereas the deep learning model requires none. Both models were higher than the clinical baseline on both metrics, so for an imaging model of iENE, the informative comparator is nodal size and not clinical variables, similar to Chapter 3’s conclusion from prognostic models (Ch.3.2.3).
The negative controls analysis approaches the question of nodal size from a different direction than the correlation and the volume baseline. The iENE model’s discrimination was lost whenever the image outside the largest node was perturbed, so its output depends on image content that those controls removed. Its predictions were only slightly changed when the interior of the largest node was shuffled or resampled. The model therefore makes little use of intranodal texture, and any sensitivity it has to interior content sits at the node and not at the primary tumour. This is anatomically plausible as iENE is defined at the nodal margins and beyond, by perinodal fat infiltration, nodal coalescence and invasion of adjacent structures, and not by the internal appearance of the node Henson 2024. Uniform random replacement shifted predictions more at the node than at the primary tumour (residual SD 0.172 and 0.071), and its fall in AUROC was distinguishable from zero only at the node (0.865, p=0.025 and 0.873, p=0.117), indicating that the model attends not to the primary tumour but the locoregional node.
Discrimination was lower in the Maastro cohort than in the RADCURE held-out set (AUROC 0.671 vs 0.913). AUPRC was nominally similar, but against a higher iENE prevalence (34.3% vs 15.3%), corresponding to a smaller gain over random chance (1.8x vs 3.9x) Saito 2015. The absence of cN0 patients from the Maastro cohort explains little since AUROC among RADCURE cN+ patients was 0.897, and labels read on diagnostic MRI or CT were not the difficulty, since the model ranked those patients better than patients labelled on the planning PET-CT (Table 4.3). Slice thickness (3.0mm vs 2.0–2.5mm) cannot be tested here, because it did not vary within the Maastro cohort. What separated the errors was the reconstructed field of view. Scans above 500mm, mostly coarser in-plane than any RADCURE scan, received lower scores whatever the label modality, so the same threshold gave a sensitivity of 83% at the narrow FOV and 29% at the wider, and an operating point would have to be set for each acquisition protocol and not only for each institution. AUROC dropped only among the 38 PET-CT labelled patients scanned at the wider FOV (AUROC 0.511) and was consistently higher in the other 137 patients (0.754). Furthermore, the calibration slope fell from 0.91 to 0.33, and the Brier score was no better than that of a constant prediction at the prevalence (Table 4.7).
This kind of miscalibration is expected when a model is moved to a cohort with a different case mix, prevalence, and labelling process, and calibration should be assessed, and the model updated at the new site Van Calster 2019. We did not recalibrate the model on the Maastro cohort, but recalibrating and evaluating on the same 175 patients may give optimistic estimates. However, since logistic recalibration changes the scale of the score and not the ranking of patients, it would not restore the discrimination that was lost (AUROC 0.671). A threshold chosen on RADCURE does not select the same kind of patients at another institution (Table 4.6), and local calibration is necessary before accepting the model’s output at its face-value probability.
The threshold analyses across subpopulations suggest that a single model can support distinct clinical use cases by selecting an appropriate operating point. At a high-specificity threshold, the model is intended to function as a staging and prognostication aid. This is particularly relevant for HPV/p16-negative patients under the 8th edition UICC/AJCC criteria, where clinically overt ENE directly influences stage assignment and surgical candidacy, as well as for the 9th edition’s incorporation of iENE for HPV-associated disease Huang 2025Brierley 2025Brierley 2026. For non-viral disease, the UICC 9th edition retains clinical ENE as the N3b criterion but now accepts unequivocal imaging findings as evidence for it Brierley 2025Brierley 2026. Whether an automated iENE determination can support that assessment in HPV/p16-negative HNSCC is a question our openly released pipeline makes testable in larger, non-viral cohorts. At a higher-sensitivity threshold, the model shifts into a screening role, flagging patients who warrant radiologist review for iENE, which is not consistently part of standard clinical practice today. In this configuration, the model enriches the review queue rather than replacing radiologist judgment, allocating expert attention toward cases most likely to harbor iENE. The ECOG-ACRIN 3311 trial of transoral surgery and de-intensified radiotherapy (RT) for HPV/p16-positive oropharyngeal cancer (OPC) illustrates this need: it enrolled participants without matted nodes, yet 31% received subsequent chemoradiotherapy after being classified high-risk on the basis of positive margins, ENE, or a high number of metastatic lymph nodes, and accurate pre-enrollment determination of iENE might have spared some of these patients from tri-modality treatment Ferris 2022. This pattern is not confined to trial populations: in a real-world SEER-Medicare cohort of locoregionally advanced HNSCC, the majority of resected patients (56%) went on to receive post-operative radiotherapy with or without systemic therapy, escalation that is frequently triggered by pathologic ENE Zheng 2025. Prospective validation is essential to translate these threshold analyses into deployment-ready parameters, with operating points tuned to each institutional workflow and clinical question.
Beyond model performance, an essential contribution of this study lies in the reproducibility and accessibility of the solution. This work is developed entirely on publicly accessible datasets from The Cancer Imaging Archive Clark 2013, and the iENE labels and train/test split for RADCURE are released via its clinical spreadsheet on TCIA, allowing any researcher to reproduce this study end-to-end and iterate on our findings Welch 2024. The full training and inference codebases, along with trained model weights, are publicly available, with environment specifications managed by pixi for single-command installation in a carbon copy of the authors' environment. Both raw DICOM images from clinical PACS and pre-processed NIfTI images are supported as input, via the open-source Med-ImageTools curation package Kim 2025.
Several limitations should be noted. Most importantly, RADCURE iENE labels came from a single radiologist, so the model inherits that reader’s thresholds and the interobserver variability documented for iENE Hoebers 2022Sahin 2025; multi-reader labels would better define the achievable ceiling. The pipeline’s main computational bottleneck is nnU-Net-based larynx segmentation Isensee 2021, though a lighter detection model may suffice given that the iENE model’s 7-fold TTA already buffers against minor crop variation Ayhan 2018Shanmugam 2021; architectural gains from attention mechanisms or added parameters are also constrained by our limited training set and overfitting risk, motivating future federated learning across institutions. Training relied on implicit radiologist determinations rather than the explicit four-tier criteria recently proposed by the Head and Neck Cancer International Group Henson 2024, and training models to directly predict for these endpoints would improve interpretability. The model was trained on oropharyngeal cancer only, limiting generalizability to other HNSCC subsites where treatment escalation is also common, and is restricted to CT input despite MRI's superior soft-tissue contrast and its use as a ground-truth modality in our external validation cohort Huang 2020. The comparison with the volume baseline rests on 25 iENE-positive patients in a single held-out set and is not available for the external cohort. Since the error profiling was post-hoc, we could test its findings directly by resampling the RADCURE held-out images to the Maastro geometry and rescoring them. Finally, the negative controls were applied at inference to a model trained only on unperturbed images, demonstrating that the model fails without the surrounding image but not what it reads there.
HypothesisPer-tooth dose reporting can be produced unattended from the planning DICOM study to help dentists make better informed and more granular decisions to manage tooth extraction and osteoradionecrosis.
Osteoradionecrosis (ORN) of the jaw is a major late toxicity of head and neck radiotherapy (RT). Its reported prevalence varies widely, from 4–8% in the era of intensity-modulated radiotherapy (IMRT) and prophylactic dental care policies to as high as 40% in earlier reports Watson 2024. A multidisciplinary consensus by Buglione and colleagues identified poor dental health before RT and post-RT extraction of teeth in highly irradiated regions as the main risk factors for ORN. Although no randomized controlled trials have assessed the safety of extraction before or after RT, observational studies have generally reported higher rates of ORN after post-RT extraction, although three studies found no significant difference Buglione 2016. The ISOO-MASCC-ASCO guideline now advises a two-week healing period between extraction and the start of RT, provided this does not delay treatment where oncologic control would be compromised Peterson 2024.
Dose is the operative variable in pre-RT dental decisions. The Canadian Dental Oncology Network (CDON) guidelines recommend considering prophylactic extraction of teeth at risk that will receive 70 Gy or more in the maxilla or 60 Gy or more in the mandible Watson 2021, and the ISOO-MASCC-ASCO guideline recommends that the planned treatment volume and the anticipated dose to the mandible and maxilla be provided to the dentist before RT begins Peterson 2024. In practice, however, this dose is reported only for the whole jaw, so whether a given tooth exceeds its threshold, which is the quantity the dentist actually needs, is currently unavailable at the chairside.
Van Dijk and colleagues developed RADMAP, a semi-automated tool that divides the mandible and maxilla into 32 tooth-bearing regions using an angular ray-based algorithm and reports the mean dose per region as a table and a heat-mapped odontogram. Across 736 tooth locations in 23 patients, the mean dose to the automatically segmented alveolar regions correlated with that to manually contoured tooth roots (R² = 0.98), and the interobserver limits of agreement across six users were ±2.88 Gy in the mandibular alveolus. Tooth-region dose distinguished ORN-affected from unaffected sites (difference in means 12.4 ± 3.7 Gy, p = 0.0008), whereas whole-mandible mean dose did not (6.2 ± 4.3 Gy, p = 0.17). However, delineating the 32 tooth regions requires 35 to 120 minutes per patient depending on operator experience, and the interactive tool reduces this burden rather than removing it, which remains a major obstacle to routine per-tooth dose reporting van Dijk 2025.
A fully automated alternative is to display the planning dose directly on the panoramic radiograph (panorex) that dentists already use. This requires registering the planning CT to the panorex, which is challenging despite both modalities depicting the same dental anatomy. A panorex is acquired by a rotating source–detector system following a predefined focal trough, resulting in non-uniform, angle-dependent magnification and blur that vary with the position of anatomical structures relative to the trough Mallya 2018Rondon 2014. A panoramic-like image derived from CT, in contrast, follows a centerline fitted to the patient’s anatomy and has more uniform magnification and sharpness. In addition, the planning CT and the panorex are often acquired at different times and in different positions, introducing genuine differences in posture, bite, head orientation and dental status. Intensity-based registration is therefore poorly suited to this task, whereas the teeth themselves provide anatomical landmarks visible in both modalities.
In this work, we present Dosarex, a pipeline that annotates the routine panorex with tooth-level planning dose, produced end-to-end from the planning CT, structure set and dose without additional human intervention, using the teeth themselves as registration landmarks. In a large institutional cohort of patients with head and neck cancer, we evaluate the consistency of the transferred dose, its agreement with the CDON extraction thresholds, and its ability to identify teeth at risk compared with whole-jaw dose reporting.
Overview. Dosarex takes two independently acquired inputs for each patient: the treatment planning CT with its structure set and planned dose distribution, and a panorex (Figure 5.1). The CT and dose volumes are first transformed into panorex-like projections by curved planar reformation along the mandible. Teeth are then segmented independently on the projected CT and on the panorex, and the centroid of each tooth is used as a landmark. The landmarks are matched between the two images and used to register the projected CT to the panorex, after which the projected dose is transferred to the panorex and the mean dose of each panorex tooth is computed.
Dataset. We retrospectively analyzed patients with head and neck cancer treated with radiotherapy at Princess Margaret Cancer Centre between 2005 and 2017, drawn from the RADCURE cohort Welch 2024. For each patient, the treatment planning CT, the structure set (RTSTRUCT) and the planned 3D dose distribution (RTDOSE) were exported from the treatment planning system, and the panorex images were retrieved and linked to the planning data through anonymized patient identifiers.
We identified 885 patients with a planning CT, an RTSTRUCT containing the mandible contour, an RTDOSE linked to the planning CT, and at least one linked panorex. Patients with several dose plans or repeat planning scans had more than one projection (938 projections in total); to give each patient equal weight, one projection per patient was selected before any processing, namely the first planning scan and, within it, the first dose plan.
Of the 885 eligible patients, 139 were excluded before analysis: 130 because fewer than two teeth were detected on the projected CT, 8 because fewer than two teeth were detected on the panorex, and 1 because the registration failed (Table 5.1). The patients without detectable teeth were predominantly edentulous, consistent with the absence of teeth on the corresponding panorex in most cases. Dosarex therefore processed 746 patients. After quality control, which excluded 34 patients (4.6%) with a registration error above 8mm, 712 patients, comprising 14,564 matched tooth pairs, were included in the dose analysis.
| Step | Patients |
|---|---|
| Eligible: CT, RTSTRUCT, dose and panorex | 885 |
| Excluded: too few teeth to register (mostly edentulous) or registration failure | −139 |
| Processed by Dosarex | 746 |
| Excluded by quality control (registration error > 8mm) | −34 |
| Analyzed (14,564 matched tooth pairs) | 712 |
Curved Planar Reformation. CPR was implemented headlessly in 3D Slicer Fedorov 2012, adapted from the CurvedPlanarReformat module of the PerkLab SlicerSandbox extension PerkLab 2026. The mandible contour from the planning RTSTRUCT was converted into a binary mask, and the medial curve (centerline) of the mandible was extracted from it. A straightening transform was computed along this curve and applied to both the CT and the dose volumes, yielding straightened volumes in which the dental arch is unfolded and the dose remains spatially aligned with the anatomy.
The straightened volumes were then projected to 2D by averaging along the bucco-lingual direction over a 30mm slab covering both jaws, yielding a panorex-like projected CT and a projected dose map with 1mm pixel spacing, in which each pixel represents the mean planning dose (Gy) through the slab.
Tooth Landmark Extraction. Tooth landmarks in each modality were obtained through a two-stage process. Each tooth is first segmented independently in the panorex and in the projected CT, after which the centroid of each segmented tooth is computed and used as its corresponding landmark. Tooth segmentation on the panorex was performed with SemiT-SAM Hao 2025. The network was initialized from its publicly released pretrained checkpoint and fine-tuned on the STS24 2D panoramic dataset Wang 2026, comprising 30 labeled and 2,350 unlabeled panorex images, following the semi-supervised teacher–student training protocol. The resulting student model was used to obtain per-tooth instance segmentation masks on all panorex images (Figure 5.2); detections with a confidence score below 0.3 were discarded. In addition to the instance masks, the model predicts one of 32 tooth classes for each detection, which was used to assign each panorex tooth to the maxilla or the mandible. Tooth segmentation on the projected CT was performed with nnU-Net Isensee 2021 in its 2D configuration, trained on 149 manually annotated projected CT images (119 for training, 30 for validation). Each image was labeled with three classes (background, tooth interior and tooth boundary), with the boundary class introduced to help the network separate closely spaced or touching teeth. The checkpoint with the best validation performance was applied to all projected CT images. Because this semantic output does not directly separate individual teeth, per-tooth instances were recovered from the predicted tooth-interior region by a post-processing step that separated teeth merged side by side (erosion and regrowth), split upper and lower teeth merged vertically (instances taller than 1.4 times the median tooth height), and cut remaining merges at minima of the tooth width profile; instances smaller than 20 pixels were discarded (Figure 5.3).
Tooth Correspondence and Registration. Because of the geometric and appearance differences between the projected CT and the panorex, registration was based on corresponding tooth landmarks rather than image intensities. Correspondence between the projected CT and panorex landmarks was established with the Hungarian algorithm Kuhn 1955 (Figure 5.4). Since the two images differ substantially in scale and resolution, each landmark set was first normalized by subtracting its mean and dividing by its standard deviation, and the algorithm paired the landmarks to minimize the total Euclidean distance between the normalized point sets. When the number of teeth differed between the two images, the excess teeth were left unmatched. The mean normalized distance of the matched pairs was recorded as the matching cost.
For registration, the projected CT was first resampled to the pixel dimensions of the panorex, and a partial affine (similarity) transformation with four degrees of freedom, consisting of rotation, uniform scaling and translation, was estimated from the matched landmark pairs. This was preferred over a full affine model because it is more stable with few or nearly collinear landmarks and does not introduce non-physical shear. The transformation was estimated by least-median-of-squares regression Rousseeuw 1984, which keeps the estimate stable when a small number of correspondences produced by the Hungarian matching are incorrect. The estimated transformation was applied to warp the projected CT, and subsequently the projected dose map, into the panorex coordinate space (Figure 5.5). Cases where the estimator failed to return a valid transformation were recorded as registration failures.
Registration accuracy was quantified as the mean Euclidean distance between the transformed projected CT landmarks and their matched panorex landmarks. Because the projected CT has isotropic 1mm pixel spacing, the residuals were mapped back into projected CT coordinates through the inverse transformation and reported in millimeters. This in-sample error is computed on the same landmarks used to estimate the transformation, which is optimized to minimize these distances; it therefore underestimates the error at locations not used for fitting, as is well established for point-based registration, where the fiducial registration error is a poor predictor of the target registration error Fitzpatrick 1998. Because dose is sampled at every tooth, the clinically relevant quantity is the error at a tooth’s location rather than at the fitting landmarks. We therefore also computed a leave-one-landmark-out error, in which each matched tooth was predicted by a transformation estimated from the remaining teeth, approximating the target registration error at a location independent of the fit. This analysis was restricted to cases with at least four matched teeth, so that at least three landmarks remained for each estimate and the robust estimator retained redundancy beyond the minimum of two correspondences required by the four-degree-of-freedom transformation.
Dose Mapping. The 3D planning dose was straightened and projected together with the CT by CPR, so the projected dose map is spatially aligned with the projected CT. This 2D dose map (in Gy) was then resampled to the panorex dimensions and warped into the panorex coordinate space with the partial affine transformation estimated during registration (Figure 5.6). For each tooth, the mean dose was computed within its mask dilated by approximately 1mm to include the tooth margin and surrounding alveolar bone, on both the projected CT (3 × 3 pixel kernel) and the panorex (kernel scaled to the panorex pixel size). The per-tooth doses of each matched tooth pair were then compared, yielding a per-tooth measure of dose consistency between the two images. The results are presented to the clinician as a report in which the tooth segmentations are overlaid on their corresponding images, with each tooth colored according to its mean dose (Figure 5.7).
Quality Control. Cases in which fewer than two teeth were detected on either image could not be registered and were excluded. Registration quality was then assessed from the registration error: cases with an error greater than one mean mesiodistal tooth width (8mm) were considered poorly registered and excluded from the dose analysis, since at this error the registered landmarks are, on average, displaced to the position of a neighboring tooth and the dose would be sampled from the wrong tooth Nelson 2019. Differences in tooth count between the two images and a low number of teeth were reported descriptively but were not used as exclusion criteria.
As a sensitivity analysis, quality control was also applied per tooth instead of per patient: each tooth was excluded if its own registration error, computed with the leave-one-landmark-out procedure (or in-sample for patients with fewer than four matched teeth), exceeded the mean mesiodistal width of its tooth type (5.0–11.0mm) Nelson 2019.
Statistical Analysis. For each matched tooth pair, the dose measured on the panorex was compared with the dose measured on the projected CT. Agreement between the two estimates was summarized by Bland–Altman analysis Bland 1986, reporting the mean difference (bias) and the 95% limits of agreement (bias ± 1.96 standard deviations of the differences), together with the mean and median absolute difference, the root-mean-square difference, the proportions of teeth agreeing within 1, 2 and 5 Gy, and the Pearson correlation coefficient. The primary analysis included all cases passing quality control.
Because overall agreement can mask systematic differences in the situations most relevant to dental decisions, the analysis was repeated in three sets of subgroups, each reflecting a known source of variation. First, the maxilla and the mandible (assigned from the panorex tooth class) were analyzed separately, because they differ in anatomy and in panoramic projection geometry, which may affect registration accuracy, and because the CDON guideline sets different extraction thresholds for each jaw. Second, teeth were grouped by CT dose (<20, 20–40, 40–60 and ≥60 Gy): a given misalignment produces a larger dose difference in steep dose gradients, which occur near the high-dose region, and extraction decisions are made at the upper end of the dose range, whereas the overall statistics are dominated by the more numerous teeth receiving intermediate doses. Third, cases with fewer than ten teeth on either image were compared with the remaining cases, since fewer landmarks constrain the registration less, and partially edentulous patients are common in this population.
To evaluate agreement at the level of the dental decision, each tooth was classified on both images as at or above versus below the CDON prophylactic-extraction threshold (≥70 Gy in the maxilla, ≥60 Gy in the mandible) Watson 2021. This analysis does not assess clinical outcomes; it tests whether using the panorex-derived dose instead of the projected CT dose would change the threshold-based recommendation for a tooth. Agreement between the two classifications was measured with percentage agreement, Cohen’s κ, sensitivity and specificity, using the projected CT as the reference. To reflect how the panorex dose could be used in practice, we also evaluated a review margin, in which teeth with a panorex dose within 2, 3, 5 or 7 Gy below the threshold were additionally flagged for review.
To quantify the value of tooth-level dose over current practice, we compared it with whole-jaw dose reporting. Because the jaw dose reported to dentists was not available for this cohort, it was approximated by assigning every tooth the mean, or alternatively the maximum, of the projected CT tooth doses in its jaw, and each tooth was classified against the CDON threshold using this single jaw value.
The association between registration error and the per-case mean absolute dose difference was assessed across all processed cases with Spearman’s rank correlation. Because teeth from the same patient are not independent, 95% confidence intervals for the agreement statistics were obtained by patient-level bootstrap (2,000 resamples of patients, percentile method).
In addition, agreement was summarized by tooth type (incisors, canines, premolars and molars) in each jaw and, in the supplementary material, by FDI tooth number, both derived from the panorex tooth class.
On the held-out set, projected CT tooth segmentation achieved a mean Dice coefficient of 0.75 for the tooth class and a tooth detection F1 score of 0.83 (precision 0.83, recall 0.84; IoU ≥ 0.5), with a median centroid error of 0.92mm for teeth matched between the annotation and the prediction. In the study cohort, a median of 23 [IQR 16–27] teeth was detected per projected CT and 24 [18–28] per panorex, of which a median of 23 [16–27] were matched (Table 5.2). Tooth counts were strongly correlated between the two images (r = 0.914); the panorex typically detected one more tooth than the projected CT (median difference 1 [IQR 0–2]), detecting more teeth in 53.9% of cases, the same number in 26.8% and fewer in 19.3%. The jaw assignment of matched pairs was consistent in 95.9% of teeth, indicating that the correspondence rarely paired teeth across jaws.
| Measure | Median [IQR] or value |
|---|---|
| Teeth per patient, projected CT | 23 [16–27] |
| Teeth per patient, panorex | 24 [18–28] |
| Matched teeth per patient | 23 [16–27] |
| Panorex detected more / same / fewer teeth than CT | 53.9% / 26.8% / 19.3% |
| Tooth count correlation (r) | 0.914 |
| Jaw agreement of matched pairs | 95.9% |
| Registration error, in-sample (mm), median [IQR] | 3.81 [2.80–5.33] |
| Registration error, leave-one-landmark-out (mm), median [IQR]* | 4.45 [3.29–6.13] |
| Quality-control limit (mm) | 8.00 |
The median registration error was 3.81mm [IQR 2.80–5.33] (mean 4.16 ± 2.18mm; Figure 5.8). Thirty-four patients (4.6%) exceeded the quality-control limit of 8mm and were excluded from the dose analysis. In the leave-one-landmark-out analysis (723 patients with at least four matched teeth), the median error was 4.45mm [IQR 3.29–6.13]; the median per-patient increase over the in-sample error was 11%, indicating that the transformation was not overfitted to the landmarks.
Per-tooth dose derived from the panorex agreed closely with that measured on the projected CT (r = 0.978, 95% CI 0.975–0.981; Figure 5.9a). The bias was −0.26 Gy (95% CI −0.36 to −0.17) with 95% limits of agreement of −6.43 to +5.90 Gy (Figure 5.9b). The mean absolute difference was 1.88 Gy (95% CI 1.79–1.96) and the median 1.07 Gy [IQR 0.40–2.37], corresponding to 1.5% of a typical 70 Gy prescription; 47.8%, 70.0% and 91.9% of teeth agreed within 1, 2 and 5 Gy, respectively (Table 5.3).
Dose differences were strongly associated with registration quality: the per-patient mean absolute difference increased with registration error (Spearman ρ = 0.68, p < 0.001; Figure 5.10), and patients who failed quality control had a median absolute difference of 5.84 Gy, compared with 1.54 Gy for those who passed.
Agreement was better in the mandible (bias +0.39 Gy, limits of agreement −4.28 to +5.05 Gy, mean absolute difference 1.55 Gy) than in the maxilla (bias −1.00 Gy, −8.25 to +6.25 Gy, 2.24 Gy). The difference increased with dose level, from a mean absolute difference of 1.07 Gy for teeth below 20 Gy to 2.68 Gy for teeth receiving 60 Gy or more, where the panorex systematically underestimated the dose (bias −2.24 Gy) (Figure 5.11, Table 5.3). By tooth type, the largest differences occurred in the maxillary molars (bias −2.43 Gy, mean absolute difference 3.59 Gy), whereas all mandibular tooth types had mean absolute differences below 1.8 Gy (Table 5.5). Patients with fewer than ten teeth showed no loss of agreement (mean absolute difference 1.29 Gy, compared with 1.90 Gy in patients with ten or more teeth).
| Subgroup | Cases | Teeth | Mean CT dose (Gy) | Bias (Gy) | LoA lower (Gy) | LoA upper (Gy) | MAE (Gy) | Median AE (Gy) | RMSE (Gy) | Pearson r | <1Gy (%) | <2Gy (%) | <5Gy(%) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| All processed cases | 746 | 15,224 | 32.26 | -0.34 | -7.43 | 6.75 | 2.05 | 1.13 | 3.63 | 0.971 | 46.6 | 68.4 | 90.7 |
| Passed QC | 712 | 14,564 | 32.37 | -0.26 | -6.43 | 5.9 | 1.88 | 1.07 | 3.16 | 0.978 | 47.8 | 70.0 | 91.9 |
| QC: maxilla | 637 | 6,828 | 30.69 | -1.0 | -8.25 | 6.25 | 2.24 | 1.25 | 3.83 | 0.97 | 44.0 | 65.1 | 88.7 |
| QC: mandible | 709 | 7,736 | 33.85 | 0.39 | -4.28 | 5.05 | 1.55 | 0.97 | 2.41 | 0.987 | 51.2 | 74.3 | 94.8 |
| QC: >= 10 teeth | 619 | 14,043 | 32.45 | -0.26 | -6.45 | 5.92 | 1.9 | 1.1 | 3.17 | 0.978 | 47.1 | 69.4 | 91.9 |
| QC: < 10 teeth | 93 | 521 | 30.15 | -0.25 | -5.77 | 5.27 | 1.29 | 0.5 | 2.82 | 0.986 | 67.6 | 85.4 | 94.4 |
| CT dose < 20 Gy | 241 | 2,534 | 9.54 | 0.0 | -3.93 | 3.93 | 1.07 | 0.47 | 2.0 | 0.959 | 67.2 | 84.5 | 96.8 |
| CT dose 20-40 Gy | 608 | 8,006 | 30.5 | 0.12 | -5.43 | 5.68 | 1.81 | 1.12 | 2.84 | 0.882 | 46.6 | 70.0 | 92.8 |
| CT dose 40-60 Gy | 500 | 3,370 | 47.43 | -1.0 | -8.64 | 6.64 | 2.47 | 1.5 | 4.02 | 0.78 | 37.0 | 60.2 | 87.5 |
| CT dose >= 60 Gy | 161 | 654 | 65.99 | -2.24 | -10.89 | 6.42 | 2.68 | 1.29 | 4.95 | 0.704 | 43.4 | 63.1 | 85.6 |
Of the 14,564 teeth, 459 (3.2%) were at or above the CDON threshold on the projected CT. Using the projected CT as reference (no clinical outcomes were assessed), the panorex classification agreed for 99.33% of teeth (κ = 0.883, 95% CI 0.852–0.911), most of which were below the threshold on both images. Of the 459 teeth at or above the threshold, the panorex identified 380 (sensitivity 0.828, 95% CI 0.777–0.875) and of 14,105 below it, it classified 14,087 (specificity 0.999) (Table 5.4). Disagreements were predominantly under-classifications: 79 teeth were at or above the threshold on the projected CT but not on the panorex, whereas 18 showed the reverse. Agreement was higher in the mandible (60 Gy; sensitivity 0.877, 95% CI 0.823–0.919; κ = 0.914) than in the maxilla (70 Gy; sensitivity 0.516, 95% CI 0.282–0.732; κ = 0.644), where only 62 teeth reached the threshold. For the 558 teeth whose CT dose lay within 5 Gy of the threshold, agreement was 83.0% (κ = 0.634). Of the 231 teeth at or above the threshold, the panorex identified 152 (sensitivity 0.658). All 79 missed teeth fell within this 5 Gy band. At the patient level, 139 of 712 patients had at least one tooth at or above the threshold, and the panorex gave the same patient-level classification for 97.3% of patients.
Flagging teeth whose panorex dose lay within 2 Gy below raised the number of 459 teeth identified from 380 to 427 (sensitivity 0.930) and 442 at 3 Gy (sensitivity 0.963). These margins flagged 3.4% and 3.9% of all teeth, respectively (Table 5.6). By comparison, whole-jaw dose reporting performed poorly in either direction: assigning each tooth the mean jaw dose identified only 211 of the 459 teeth at or above the threshold (46.0%), whereas assigning the maximum jaw dose identified all 459 but flagged 12.4% of all teeth, 4.6 times as many as the per-tooth panorex dose (2.7%).
Applying quality control per tooth instead of per patient retained 744 patients and 12,493 teeth, excluding 17.9% of teeth, mainly mandibular incisors (the narrowest teeth) and maxillary molars, while recovering 223 well-aligned teeth from 33 patients that had failed the per-patient limit. Agreement improved (bias −0.11 Gy; 95% limits of agreement −4.39 to +4.17 Gy; mean absolute difference 1.45 Gy), whereas threshold classification was essentially unchanged (agreement 99.42%, sensitivity 0.842, specificity 0.999).
| Subgroup | Teeth | CT above threshold | Both above (TP) | Both below (TN) | Pano above only (FP) | Pano below only (FN) | Agreement (%) | Cohen kappa | Sensitivity | Specificity |
|---|---|---|---|---|---|---|---|---|---|---|
| All (70 Gy maxilla / 60 Gy mandible) | 14,564 | 459 | 380 | 14,087 | 18 | 79 | 99.33% | 0.883 | 0.828 | 0.999 |
| Maxilla (70 Gy) | 6,828 | 62 | 32 | 6,761 | 5 | 30 | 99.49% | 0.644 | 0.516 | 0.999 |
| Mandible (60 Gy) | 7,736 | 397 | 348 | 7,326 | 13 | 49 | 99.2% | 0.914 | 0.877 | 0.998 |
| <5 Gy of threshold | 558 | 231 | 152 | 311 | 16 | 79 | 82.97% | 0.634 | 0.658 | 0.951 |
| Jaw | Tooth type | Teeth | Mean CT dose (Gy) | Bias (Gy) | MAE (Gy) | Within 2Gy (%) |
At/above threshold on CT | Threshold agreement (%) | Sensitivity |
|---|---|---|---|---|---|---|---|---|---|
| Maxilla | Incisors | 2,040 | 25.5 | -0.24 | 1.28 | 82.3 | 14 | 99.6% | 0.50 |
| Canines | 1,115 | 28.2 | -0.52 | 2.03 | 64.1 | 12 | 99.5% | 0.50 | |
| Premolars | 1,773 | 31.6 | -0.65 | 2.04 | 65.5 | 20 | 99.4% | 0.50 | |
| Molars | 1,900 | 36.9 | -2.43 | 3.59 | 46.9 | 16 | 99.5% | 0.56 | |
| Mandible | Incisors | 2,188 | 28.7 | 0.75 | 1.4 | 77.2 | 64 | 99.6% | 0.91 |
| Canines | 1,329 | 30.9 | 1.04 | 1.63 | 72.4 | 38 | 99.3% | 0.84 | |
| Premolars | 2,234 | 34.3 | 0.69 | 1.49 | 76.3 | 100 | 99.3% | 0.88 | |
| Molars | 1,985 | 41.0 | -0.79 | 1.74 | 70.0 | 195 | 98.5% | 0.87 |
| Approach | Sensitivity | Specificity | Teeth flagged (%) | Missed teeth |
|---|---|---|---|---|
| Whole-jaw mean dose | 0.46 | 0.997 | 1.7% | 248 |
| Whole-jaw maximum dose | 1.00 | 0.904 | 12.4% | 0 |
| Dosarex (per-tooth dose) | 0.828 | 0.999 | 2.7% | 79 |
| Dosarex, 2 Gy review margin | 0.930 | 0.995 | 3.4% | 32 |
| Dosarex, 3 Gy review margin | 0.963 | 0.991 | 3.9% | 17 |
| Dosarex, 5 Gy review margin | 0.976 | 0.983 | 4.8% | 11 |
Dosarex automatically annotates routine panorex with tooth-level planning dose, without manual delineation, with close agreement to the projected planning dose and high overall agreement on CDON extraction-threshold classification across a large institutional cohort. By overlaying tooth-level dose on a format dentists already use, Dosarex can support pre-radiotherapy dental decision-making. In 712 patients and 14,564 teeth, the dose transferred to the panorex reproduced the dose measured on the projected CT with a median difference of about 1 Gy and negligible overall bias, and the two images agreed on whether a tooth reached the CDON extraction threshold for 99.3% of all teeth. Of the 459 teeth at or above the threshold, the Dosarex pipeline can identify 380 (sensitivity 0.83) based on the panorex, and up to 442 (sensitivity 0.963) by increasing the review margin. The leave-one-landmark-out error was close to the in-sample error, indicating that the registration generalizes beyond the landmarks used to estimate it. The pipeline ran unattended from the planning DICOM study to the per-tooth report for 746 of the 885 eligible patients, 138 of the 139 it could not process had fewer than two teeth detected on one of the two images, and most of these were edentulous.
Registration was the main source of disagreement. Dose differences increased steadily with registration error, and the few cases that failed quality control accounted for the largest discrepancies. This is consistent with the geometric differences between the two modalities: the non-uniform, angle-dependent magnification of the panorex cannot be fully captured by a single partial affine transformation. Non-rigid registration, or explicit modeling of the panoramic focal trough, is therefore the most direct route to further improving accuracy.
Per-tooth quality control further narrowed the limits of agreement to about ±4 Gy, indicating that much of the remaining disagreement comes from a minority of individually misaligned teeth. Because the per-tooth error is available without any dose reference, it could be used to flag teeth with uncertain dose in the clinical report rather than excluding the whole patient.
The panorex tended to underestimate dose to the most highly irradiated teeth, particularly in the maxilla. In steep dose gradients, small misalignments shift the tooth mask partly into lower-dose regions, pulling the per-tooth mean downward. Clinically, this is the less safe type of error, since a tooth at or above the threshold may be reported as below it; sensitivity was 0.83 overall and 0.52 in the maxilla, where few teeth reached 70 Gy. Until registration is further improved, teeth whose panorex dose lies within a margin of the threshold (for example 3 Gy, which recovered 96% of teeth at or above the threshold) could be flagged for review rather than classified automatically.
The limits of agreement observed here (approximately ±6 Gy) are wider than the interobserver limits reported for RADMAP (±2.88 Gy) van Dijk 2025. The two quantities are not directly comparable, however: RADMAP’s limits describe agreement between observers on the same image, whereas ours describe agreement between two independently acquired images of different modalities.
In clinical terms, the median difference of 1.07 Gy corresponds to 1.5% of a typical 70 Gy prescription, and the limits of agreement (about ±6 Gy) are half the 12.4 Gy difference in tooth-region dose that separated ORN-affected from unaffected sites van Dijk 2025. The differences that matter for decisions occur near the extraction thresholds, where a 3 Gy review margin recovered 96% of teeth at or above the threshold while flagging fewer than 4% of teeth for review.
The comparison with current practice bears most directly on the dental decision. A single whole-jaw value cannot serve a tooth-level threshold: the mean jaw dose identified 46% of the teeth at or above the threshold, and the maximum jaw dose identified all of them only by flagging 12.4% of all teeth, 4.6 times as many as the per-tooth dose. Per-tooth dose with a 3 Gy review margin identified 96% of these teeth while flagging 3.9%. The whole-jaw values were approximated from projected CT tooth doses, because the jaw dose reported to dentists was not available for this cohort, so the comparison should be repeated against the dose reported in clinic.
Our study has some limitations. The comparison between projected CT and panorex measures the consistency of dose transfer rather than accuracy against the true 3D dose to each tooth, and the dose projection averages over a 30mm bucco-lingual slab. In addition, panoramic acquisition dates were not available, so changes in dental status between the panorex and the planning CT could not be accounted for. The cohort comes from a single institution, and the projected CT segmentation model was trained on 149 images from the same source, so performance on other scanners, panoramic units and patient populations is untested. Finally, the pipeline does not process every sample flawlessly, 34 of 885 patients (3.8%) failed quality control.
This study can be expanded to validate Dosarex against the true 3D dose to each tooth, by comparing its per-tooth values with the mean dose within manually contoured tooth volumes on the planning CT for a subset of patients and validated externally on data from other institutions. Beyond technical validation, combining per-tooth dose with clinical features to model per-tooth ORN risk would establish whether the reported dose can reliably inform extraction decisions. The existing per-tooth dose-ORN analysis rests on 23 patients and 21 affected tooth regions van Dijk 2025. Since Dosarex is fully automated, it can be applied retrospectively to entire institutional cohorts, enabling per-tooth dose–outcome analyses at a scale not previously feasible, including graded ORN severity rather than ORN alone: the ClinRad classification grades the vertical extent of necrosis and the presence of exposed bone or fistula Watson 2024, so models can be trained on graded outcomes.
Furthermore, if per-tooth dose is available automatically at planning time, it can become an input to plan optimization rather than only a reporting output. Current dose constraints for the jaw are defined at the level of the whole mandible or jaw; mandibular NTCP model constrains 30% of the mandible to 35 Gy or 42 Gy depending on pre-radiotherapy extraction status van Dijk 2021, and the ISOO-MASCC-ASCO guideline advises reducing the mean dose to the jaw and the volume of bone above 50 Gy wherever possible Peterson 2024. A per-tooth objective would allow dose to be traded between tooth regions according to which teeth the dentist intends to retain. Together, these directions position Dosarex as a foundation for large-scale per-tooth dose–outcome studies and tooth-aware radiotherapy planning.
The distance between a raw, clinical dataset and a complex clinical decision is usually described as a modelling problem. This thesis measured that distance differently.
This thesis contributed, in order:
RADCURE: The largest public head and neck CT collection (n=3,346)
Med-ImageTools: An open-source Python package for medical imaging dataset processing validated at scale
Four evaluation studies investigating what imaging models actually learn:
RADCURE-challenge: institution-wide challenge to predict survival and personalized prognosis
Deep-CR-MTLR: a novel competing-risks survival modelling method to investigate cause-specific survival
READII-2-ROQC: a nine-condition negative-control framework
SCARF: a quantitative evaluation of segmentation models and blinded clinical acceptability benchmark
Patient-level iENE model, externally validated, with comprehensive model evaluations, including varying clinical operating thresholds
Dosarex, a fully automated pipeline that reports radiation dose per tooth on routine panoramic radiographs, without any manual contouring or operator intervention.
Miscellaneous methods works include: FastCPH, FAIR-HNC, and jarvAIs.
The evidence supports the four hypotheses of Chapter 1.12 to differing degrees. The curation of the largest head and neck cancer imaging dataset and open-source software package for automated preprocessing supports the original hypothesis, as shown by the time-savings and large adoption of the RADCURE dataset by other studies. In Chapter 3, the prognostic performance was largely attributable to tumour volume or extratumoural context (Ch.3.2.3 and Ch.3.4.3), and rankings by geometric performance and by clinical acceptability diverged (Ch.3.5.4), supporting the hypothesis. The Chapter 4 hypothesis is partially supported since the iENE model outperformed the clinical baseline, while its margin over the volume baseline was not distinguishable from zero in paired comparison (Table 4.2, Supp.Table 4). Stratification of distant control at τ=0.50 was comparable to that of the radiologist in both cohorts (Table 4.5). For distant failure within 2 years, the model at τ=0.50 gave a net benefit similar to the radiologist’s determination in both cohorts (Table 4.8). Dosarex meets the Chapter 5 hypothesis halfway, the pipeline having been implemented and technically validated by comparing dose consistencies between the panorex and projected CT. However, the evaluation of accuracy against 3D dose and whether it helps dentists make better informed decisions have not been tested yet.
Reproducibility in this thesis is not a stated virtue but an evidenced property. Med-ImageTools is the processing engine for all of the projects built on the RADCURE dataset: SCARF's CONSORT-AI accounting credits Med-ImageTools data curation with 240 of 450 developer-hours saved; READII-2-ROQC builds its provenance layer on the same tooling. And the iENE model ships as a fully reproducible study, from public training data, released labels and split, weights, and locked environment—contributions equal in weight to its AUROC, allowing an external group to scrutinize the held-out result and test on their own datasets without our involvement.
jarvAIs is an open-source Python package for reproducible machine learning research on oncology data. It packages every decision along the development process into reproducible, configurable settings, including training data auditing, model hyperparameter selection, feature reduction and selection choices, validation splits, bias detection, model interpretability modules, and post-hoc fairness audits. We compared jarvAIs to AIM2REDUCE-ED, a hand-built model for 30-day emergency department visits during systemic therapy at Princess Margaret, currently in silent deployment Grant 2023Kabir 2024. The automated jarvAIs pipeline matched it on the held-out set (AUROC 0.70 vs 0.69, AUPRC 0.23 vs 0.20), trailed it modestly in the prospective cohort (0.67 vs 0.69, AUPRC 0.11 vs 0.16), and identified the treatment-regimen subgroups a manual bias analysis had flagged, in under thirty minutes of development time Siraj 2025. Reproducibility does not have to be expensive if the infrastructure and tooling are developed intentionally and used as the default path, paving a translational highway for machine learning models into the clinic.
The RADCURE challenge (Ch.3.2) measured the tumour volume confounder in the wild. Engineered radiomics predictions correlated with volume at ρ=0.79 to 0.85, and the winning model used EMR features plus volume explicitly. The same pattern appeared in our multi-institutional federated study, where a Cox model on clinical variables (n=1,492) reached a C-index of 0.62 to 0.73 across nodes, a radiomics-only model (n=1,321) reached 0.61 to 0.68, and the mixed model reached 0.60 to 0.72, with no improvement over the clinical model alone Gouthamchand 2024. READII-2-ROQC (Ch.3.4) turned the observation into a controlled test. The Aerts signature survived nine negative controls unchanged and never separated from the volume-only baseline, and the foundation model's features were shown to derive from the background rather than the tumour. SCARF (Ch.3.5) demonstrated that geometric rankings and clinical acceptability rankings diverge.
The common lesson is that AUROC, DSC and C-index are proxies of the underlying metric we’re actually interested in. Each is chosen because it is tractable, not because it is the quantity a clinician cares about, and we believe a proxy's job is to predict how well a model serves a specific decision. SCARF demonstrates that a proxy can do that job measurably poorly at the extremes, and the RADCURE-challenge and READII results show that a strong number can describe tumour size or surrounding context rather than the tumour itself. None of this means imaging is uninformative. Model 9 from the RADCURE-challenge reached AUROC 0.766 at ρ=0.22, and READII identified a class of features that responds to structured perturbation while remaining independent of volume. Imaging signal is learnable, but it must be demonstrated by construction. Volume correlation analysis, negative controls, ablation evidence, and superiority over a volume baseline are what can separate a model that has learned valuable features beyond tumour volume, and we believe they should be as routine as cross-validation.
The iENE model in Chapter 4 was designed against the findings above rather than evaluated against them after the fact. Its correlation with the largest nodal volume was characterized directly (Pearson r = 0.335, Spearman ρ = 0.587), it confidently rejected several cases with very large GTVn, and it scored above the volume baseline on both AUROC and AUPRC, although the paired differences were not distinguishable from zero. The READII-2-ROQC negative controls tie the model’s output to the node and its surroundings and not to the interior of the primary tumour, but it does not fully separate the model from nodal size. We used ACS convolutions on the full neck volume rather than on segmented nodes, removing the dependency on a lymph node contour—an auto-segmentation step that, as SCARF showed even for well-defined OARs, cannot be assumed clinically acceptable on the strength of geometric metrics. What the model could not remove is the variability in the radiologist labels it was trained on, but we instead leveraged the clinician’s labels to compare against the model’s predictions to characterize its prognostic performance. We evaluated the effect of varying decision thresholds, acknowledging that one model serves two decisions with different costs of error, and treated τ as a clinical dial rather than a nuisance parameter.
Dosarex is the clearest case in this thesis of a design driven by the decision rather than by the data. The decision is whether to extract a specific tooth before radiotherapy, against external thresholds of 70 Gy in the maxilla and 60 Gy in the mandible Watson 2021, yet dose is conventionally reported for the whole jaw, and whole-mandible dose does not reliably predict ORN where per-tooth dose does van Dijk 2025. Dosarex reports the dose estimate on the panorex dentists routinely read, at the level of the individual tooth on which the extraction decision can be made, without requiring manual delineation. Across 14,564 teeth in 712 patients, it agreed with the projected planning dose to a median absolute difference of 1.07 Gy and identified 380 of the 459 teeth at or above the CDON threshold classification (83%) while flagging 2.7% of all teeth, up to 442 teeth by flagging 3.9% of all teeth. On the contrary, the whole-jaw mean found 211 (46%) and the whole-jaw maximum found all 459 only by flagging 12.4% of all teeth. While these results establish consistent dose transfer, there is no evidence of accuracy against the 3D dose or clinical benefit to patients.
Our studies can continue into several different directions:
Federated learning addresses both the training-scale limit and the single-institution limit without relocating sensitive patient data. Gouthamchand and colleagues federated five head and neck cohorts that shared no schema at their point of origin, comprising HN1, HNSCC, HEAD-NECK, a private MAASTRO dataset, and the Princess Margaret OPC-Radiomics collection, which our group prepared and hosted as the Canadian node. Data content was decoupled from schema into RDF, annotated with the Radiation Oncology Ontology and the NCI Thesaurus as a metadata layer, and read back through a single semantic query. Federated Cox models were then trained and validated across the network by leave-one-dataset-out internal-external validation under the Personal Health Train paradigm, with no patient-level data leaving any station Gouthamchand 2024. The infrastructure to federate both conventional and deep learning models already exists, and international collaborations have been successfully demonstrated Choudhury 2025. Chapter 4 showed that architectural gains from attention or added capacity are constrained by a training set of 752 patients, and that a single external cohort with a different case mix reduced AUROC from 0.913 to 0.671. A federated iENE study across the institutions that already contribute to these networks is the most direct way to test whether the model's performance is limited by data or by the problem. Med-ImageTools was designed with this use in mind, since each participating node can run the same processing pipelines without requiring any manual curation and produce identically structured ML-ready data.
Better labels, better decisions. iENE is a radiologist determination with documented interobserver variability Hoebers 2022Sahin 2025. Every model trained on it inherits that variability as a ceiling, and the single-reader labels used in our study are the greatest limitation Kim 2026. Hoebers and colleagues showed that concordance is trainable, with inter-institutional kappa rising from 0.40 to 0.65 once operating definitions were consolidated Hoebers 2022. The Head and Neck Cancer International Group consensus criteria published in 2024 replaced an informal reading of iENE with a four-tier classification and an explicit rule for equivocal findings, and all seventeen surveyed experts said they would adopt synoptic reporting in routine practice Henson 2024. This means that grade-level, multi-reader labels can be generated prospectively as part of routine reporting rather than as a separate research exercise. A model trained on HNCIG synoptic reports would produce outputs that map directly onto the 9th edition staging variable, distinguishing perinodal fat extension from conglomerate nodes from invasion of adjacent structures and would be interpretable against criteria that carry known diagnostic confidence. This is the change most likely to move the iENE model from a research result to a clinical instrument, and it depends more on reporting practice than on modelling.
Beyond oropharynx. The iENE model was trained on a cohort only with oropharyngeal cancer patients. Treatment escalation driven by ENE is also common in oral cavity and laryngeal disease, and the 9th edition now uses unequivocal iENE as a criterion for cN3 in non-viral head and neck cancer Brierley 2026, so the same prediction target applies across subsites. Extending our study to other subsites will test the model’s generalizability and reveal whether to expand the training set to non-OPC cohorts with iENE labels.
Beyond CT. The iENE model is restricted to CT despite the superior soft-tissue contrast of MRI, and the Maastro validation showed that labels made on MRI were predicted nearly as well as labels made on CT. This suggests the planning CT carries more of the relevant signal than is usually assumed, but a direct comparison with MRI input, or a multimodal model where both are available, has not yet been done in existing literature, according to our best knowledge.
From dose consistency to dose–outcome. Dosarex has so far been validated for consistency against the projected CT. The first step of validation is comparing Dosarex’s output against the mean dose in manually contoured tooth volumes on the planning CT. A clinical validation could be comparing per-tooth dose–outcome modelling against graded ORN severity Watson 2024, where the existing evidence rests on 23 patients van Dijk 2025. Per-tooth dose available at planning time could then become a planning objective. Lastly, integration into the clinic is already underway, with dental practitioners eager for adoption to make more granular decisions on which teeth to preserve.
Deployment is an art. Every model in this thesis was built to be run by someone else. The remaining step is to make running them routine rather than possible. SCARF is already embedded in MIRA, the institutional platform that extracted RADCURE, and the jarvAIs API service was built to serve models into the same infrastructure. Serving the iENE model and the Dosarex pipeline through MIRA, with Med-ImageTools handling DICOM input and containerizing our software with fully reproducible environments, would close the translational loop. This integration would blaze the trail for the next area of research of implementation science, investigating how AI systems augment and impact clinical decision making.
The distance between a raw, clinical dataset and a complex clinical decision is usually described as a modelling problem. This thesis measured that distance differently. First, curation is a scientific step and should be treated as one. The choices made while converting DICOM into model inputs shape every downstream result, and Med-ImageTools exists so that those choices are written down, versioned, and repeatable. Second, a performance metric is a claim about a model that must itself be tested. The volume confounder, the negative-control results, and the gap between geometric accuracy and clinical acceptability all show that a strong number can describe something other than what it appears to describe. Third, a model earns clinical relevance by being aimed at a decision. Our iENE model’s output lives on the scale a radiologist uses and a staging system now requires, and Dosarex reports dose at the level a dentist acts on. None of this replaces the clinician—the iENE model enriches a review queue, Dosarex informs a chairside decision, and both leave the critical judgment where it belongs. What our studies offer is a way of building these tools so that the judgment they support is better informed, and the evidence behind them can be checked by anyone who wants to. An imaging AI model is trustworthy when its data pipeline is transparent and reproducible, its signal is thoroughly characterized, and its output is aimed at a real clinical decision to assist responsibly.
Statement of contributions
This thesis is manuscript-based. The chapters incorporate most of the following works I contributed to during the duration of my PhD.
I hold first / co-first authorship on five public works (Med-ImageTools, RADCURE, RADCURE-challenge, Deep-CR-MTLR, and iENE), led the software development of two open-source Python packages: Med-ImageTools and jarvAIs, and first authorship on the iENE manuscript under review at Lancet Digital Health and co-first authorship of the Dosarex manuscript in preparation.
Medical Physics 2024;51(4):3101–3109
F1000Research 2025;12:118 (v3)
Cancer Res Comms 2023;3(6):1140–1151
AAAI Spring Symposium 2021
NeurIPS 2022 Workshop HITY, TS4H
ICHNO 2024, ICCR 2024Cancer Research, in submission
phiRO 2026;39:101015
ICHNO 2024, Best Paper AwardJournal of Clinical Oncology, under review
In preparation
Clinical Cancer Research (2025) 31; B001
BJR Artificial Intelligence 1.1 (2024)
150 works cited
Glossary
Appendix
| Demographics | |
|---|---|
| Age (years) | 62.3(15.6-90.0) |
| Sex | |
Male Female |
2660(79.5%) 686(20.5%) |
| Smoking Status | |
Non-smoker Ex-smoker Current Unknown |
871(26.0%) 1289(38.5%) 1139(34.0%) 45(1.3%) |
| Clinical Variables | |
| Disease Site | |
Oropharynx Larynx Nasopharynx Hypopharynx Oral Cavity Nasal Cavity Esophagus Paranasal Sinus Salivary Glands Other/Unknown |
1501(44.9%) 877(26.2%) 355(10.6%) 162(4.8%) 100(3.0%) 62(1.9%) 33(1.0%) 28(0.8%) 4(0.1%) 224(6.7%) |
| ECOG | |
ECOG 0 ECOG 1 ECOG 2 ECOG 3 ECOG 4 Unknown |
2027(60.6%) 1031(30.8%) 209(6.2%) 41(1.2%) 6(0.2%) 31(0.9%) |
| N-Stage | |
N0 N1 N2 N2a N2b N2c N3 N3a N3b NX |
1147(34.3%) 344(10.3%) 182(5.4%) 125(3.7%) 791(23.6%) 532(15.9%) 170(5.1%) 28(0.8%) 13(0.4%) 1(0.03%) |
| T-Stage | |
T0 Tis T1 T1a T1b T2 T2a T2b T3 T4 T4a T4b |
168(5.0%) 44(1.3%) 455(13.6%) 179(5.3%) 88(2.6%) 928(27.8%) 4(0.1%) 5(0.1%) 862(25.8%) 116(3.5%) 358(10.7%) 121(3.6%) |
| Overall Stage | |
0 I II III IV IVA IVB IVC X |
44(1.3%) 353(10.5%) 403(12.0%) 609(18.2%) 12(0.4%) 1581(47.3%) 309(9.2%) 2(0.06%) 6(0.2%) |
| Rank | shuffled _full |
sampled _full |
randomized_full | shuffled _roi |
sampled _roi |
randomized_roi | shuffled _non_roi |
sampled _non_roi |
randomized_non_roi |
|---|---|---|---|---|---|---|---|---|---|
| 1 | exponential_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis |
| 2 | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | square_glcm_ClusterProminence | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-HHH_glszm_SmallAreaEmphasis | exponential_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glszm_SmallAreaHighGrayLevelEmphasis |
| 3 | square_glszm_SmallAreaHighGrayLevelEmphasis | square_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glcm_ClusterProminence | exponential_ngtdm_Coarseness | exponential_ngtdm_Coarseness | exponential_glszm_SmallAreaEmphasis | square_glszm_SmallAreaHighGrayLevelEmphasis | square_glszm_SmallAreaHighGrayLevelEmphasis | square_glszm_SmallAreaHighGrayLevelEmphasis |
| 4 | square_glcm_ClusterProminence | square_glcm_ClusterProminence | exponential_glszm_SmallAreaHighGrayLevelEmphasis | square_ngtdm_Coarseness | square_ngtdm_Coarseness | exponential_glcm_ClusterProminence | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis |
| 5 | exponential_glcm_ClusterProminence | square_ngtdm_Complexity | square_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glszm_SmallAreaEmphasis |
| 6 | square_ngtdm_Complexity | exponential_glcm_ClusterProminence | square_ngtdm_Complexity | exponential_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glszm_SmallAreaLowGrayLevelEmphasis | exponential_ngtdm_Coarseness | exponential_ngtdm_Coarseness | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis |
| 7 | exponential_glszm_SmallAreaEmphasis | exponential_glszm_SmallAreaEmphasis | wavelet-HHL_glcm_ClusterProminence | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | exponential_glcm_ClusterProminence | exponential_glcm_ClusterProminence | square_glcm_ClusterProminence |
| 8 | exponential_ngtdm_Coarseness | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | exponential_ngtdm_Complexity | exponential_glszm_SmallAreaEmphasis | wavelet-LHH_glszm_SmallAreaEmphasis | square_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-HHL_glcm_ClusterProminence |
| 9 | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | exponential_ngtdm_Coarseness | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HLH_glszm_SmallAreaEmphasis | wavelet-HHH_glcm_ClusterProminence | exponential_glszm_SmallAreaEmphasis | exponential_glszm_SmallAreaEmphasis | exponential_glszm_SmallAreaLowGrayLevelEmphasis |
| 10 | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHH_glcm_ClusterProminence | wavelet-LHH_glszm_SmallAreaEmphasis | wavelet-HLH_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-HHL_glcm_ClusterProminence | square_glszm_SmallAreaEmphasis | square_glszm_SmallAreaEmphasis | wavelet-HHH_glszm_SmallAreaEmphasis |
| 11 | square_glcm_ClusterShade | square_glcm_ClusterShade | square_glcm_ClusterShade | wavelet-HLH_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-LHH_glszm_SmallAreaLowGrayLevelEmphasis | exponential_ngtdm_Complexity | square_glcm_ClusterProminence | square_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterProminence |
| 12 | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HLH_glszm_SmallAreaEmphasis | exponential_glcm_MCC | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | wavelet-HHL_glcm_ClusterProminence | exponential_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-LHH_glcm_ClusterProminence |
| 13 | exponential_glszm_SmallAreaLowGrayLevelEmphasis | exponential_glszm_SmallAreaLowGrayLevelEmphasis | exponential_glcm_ClusterShade | exponential_glszm_SmallAreaLowGrayLevelEmphasis | exponential_glszm_SmallAreaHighGrayLevelEmphasis | square_glszm_SmallAreaEmphasis | exponential_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-HHL_glcm_ClusterProminence | wavelet-HLH_glcm_ClusterProminence |
| 14 | wavelet-HHL_glcm_ClusterProminence | wavelet-HHL_glcm_ClusterProminence | wavelet-LHH_glcm_ClusterProminence | exponential_glcm_MCC | wavelet-HHH_glcm_ClusterShade | wavelet-HHH_glszm_SmallAreaLowGrayLevelEmphasis | square_ngtdm_Complexity | square_ngtdm_Complexity | logarithm_glcm_ClusterProminence |
| 15 | square_ngtdm_Contrast | square_ngtdm_Contrast | wavelet-HLH_glcm_ClusterProminence | wavelet-LHH_glszm_SmallAreaLowGrayLevelEmphasis | wavelet-HHL_glcm_ClusterShade | exponential_glcm_ClusterShade | wavelet-LHL_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterShade | wavelet-LHL_glcm_ClusterProminence |
| 16 | square_glszm_SmallAreaEmphasis | square_glszm_SmallAreaEmphasis | exponential_glszm_SmallAreaEmphasis | wavelet-HHH_glcm_ClusterShade | exponential_glcm_Correlation | wavelet-HLH_glcm_ClusterProminence | square_glszm_SmallAreaLowGrayLevelEmphasis | square_glszm_SmallAreaLowGrayLevelEmphasis | square_ngtdm_Complexity |
| 17 | wavelet-HHH_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterProminence | wavelet-LHL_glcm_ClusterProminence | wavelet-HHL_glcm_ClusterShade | wavelet-HHL_glcm_ClusterProminence | wavelet-LHH_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterProminence | square_glszm_SmallAreaEmphasis |
| 18 | square_glcm_Contrast | square_glcm_Contrast | wavelet-HLL_glcm_ClusterProminence | wavelet-HHL_glcm_ClusterProminence | wavelet-HHH_glszm_ZoneVariance | square_glszm_SmallAreaLowGrayLevelEmphasis | exponential_glcm_ClusterShade | exponential_glcm_ClusterShade | wavelet-HLL_glcm_ClusterProminence |
| 19 | square_glcm_ClusterTendency | square_glcm_ClusterTendency | exponential_firstorder_Variance | exponential_glcm_Correlation | exponential_glszm_SmallAreaEmphasis | wavelet-LHH_glszm_SmallAreaEmphasis | wavelet-HHH_glcm_ClusterShade | logarithm_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterShade |
| 20 | square_glcm_SumSquares | square_glcm_SumSquares | wavelet-HHH_glszm_SmallAreaEmphasis | wavelet-HHH_glszm_ZoneVariance | wavelet-HHH_glcm_ClusterProminence | wavelet-HHH_glcm_ClusterShade | logarithm_glcm_ClusterProminence | wavelet-LHH_glcm_ClusterProminence | exponential_ngtdm_Coarseness |
| Rank | Feature | Average rank | Mean magnitude (%) |
|---|---|---|---|
| 1 | wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis | 1.22 | 1.78×10¹¹ |
| 2 | exponential_glszm_SmallAreaHighGrayLevelEmphasis | 3.67 | 1.01×10¹¹ |
| 3 | wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis | 6.56 | 8.00×10⁸ |
| 4 | wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis | 8.33 | 4.89×10⁸ |
| 5 | wavelet-HHH_glszm_SmallAreaEmphasis | 8.78 | 8.93×10⁷ |
| 6 | exponential_glszm_SmallAreaEmphasis | 9.22 | 3.31×10⁸ |
| 7 | wavelet-HHL_glcm_ClusterProminence | 12.56 | 9.83×10⁸ |
| 8 | exponential_glszm_SmallAreaLowGrayLevelEmphasis | 14.44 | 5.08×10⁷ |
| 9 | wavelet-HHH_glcm_ClusterProminence | 15.44 | 4.14×10⁸ |
| 10 | wavelet-HHH_glcm_ClusterShade | 19.67 | 1.43×10⁷ |
| ΔAUROC (95% CI), p-value | Clinical | Mixed | Volume |
|---|---|---|---|
| iENE | 0.232 (0.135–0.339) p=0.001 |
0.127 (0.046–0.221) p=0.002 |
0.062 (−0.004 to 0.134) p=0.067 |
| Volume | 0.170 (0.093–0.255) p=0.001 |
0.065 (0.019–0.125) p=0.005 |
|
| Mixed | 0.105 (0.048–0.168) p=0.001 |
| ΔAUPRC (95% CI), p-value | Clinical | Mixed | Volume |
|---|---|---|---|
| iENE | 0.282 (0.085–0.489) p=0.011 |
0.129 (−0.083 to 0.332) p=0.219 |
+0.105 (−0.109 to 0.302) p=0.334 |
| Volume | 0.177 (0.024–0.362) p=0.032 |
0.024 (−0.051 to 0.107) p=0.538 |
|
| Mixed | 0.153 (0.013–0.305) p=0.033 |
| τ | iENE HR (95% CI) | Volume HR (95% CI) |
|---|---|---|
| 0.25 | 5.07 (2.16–11.87) | 4.56 (1.83–11.37) |
| 0.50 | 8.30 (3.58–19.25) | 2.99 (0.69–12.93) |
| 0.75 | 6.29 (2.58–15.35)* | 1.62 (0.22–12.13) |
| Type of control | Largest GTVn | GTVp | |||||
|---|---|---|---|---|---|---|---|
AUROC p-value |
Pearson r |
Residual SD | AUROC p-value |
Pearson r |
Residual SD | ||
| original | 0.908 | 1.000 | - | 0.908 | 1.000 | - | |
| shuffled | ROI | 0.877 p=0.197 |
0.987 | 0.045 | 0.907 p=0.662 |
0.997 | 0.020 |
| sampled | 0.878 p=0.176 |
0.986 | 0.047 | 0.908 p=0.914 |
0.997 | 0.020 | |
| randomized | 0.865 p=0.025 |
0.793 | 0.172 | 0.873 p=0.117 |
0.966 | 0.071 | |
| shuffled | non-ROI | 0.472 p<0.001 |
0.102 | 0.268 | 0.496 p<0.001 |
0.006 | 0.269 |
| sampled | 0.517 p<0.001 |
0.123 | 0.268 | 0.515 p<0.001 |
0.005 | 0.269 | |
| randomized | 0.441 p<0.001 |
−0.111 | 0.303 | 0.467 p<0.001 |
−0.085 | 0.301 | |
| shuffled | Full | 0.576 p<0.001 |
0.122 | 0.269 | 0.576 p<0.001 |
0.122 | 0.269 |
| sampled | 0.492 p<0.001 |
0.091 | 0.269 | 0.492 p<0.001 |
0.091 | 0.269 | |
| randomized | 0.466 p<0.001 |
−0.083 | 0.301 | 0.466 p<0.001 |
−0.083 | 0.301 | |
| Characteristic | RADCURE (n=915) | Maastro (n=175) | SMD | p | q |
|---|---|---|---|---|---|
| Clinical | |||||
| Age, years | 60.9 (54.3–68.0) | 62.1 (56.0–67.8) | 0.11 | 0.158 | 0.168 |
| Male sex | 743 (81.2%) | 131 (74.9%) | −0.15 | 0.054 | 0.061 |
| Smoking, pack-years | 20.0 (0.0–40.0) | 23.0 (6.0–36.0) | 0.02 | 0.301 | 0.301 |
| Smoking ≥10 pack-years | 559/911 (61.4%) | 122/169 (72.2%) | 0.23 | 0.007 | 0.010 |
| HPV positive | 645/899 (71.7%) | 101 (57.7%) | −0.30 | <0.001 | <0.001 |
| T3–T4 | 424/914 (46.4%) | 99 (56.6%) | 0.20 | 0.014 | 0.016 |
| cN0 | 146 (16.0%) | 0 (0.0%) | −0.62 | <0.001 | <0.001 |
| N category* | N0: 146 (16.0%) N1: 78 (8.5%) N2: 636 (69.5%) N3: 55 (6.0%) |
N1: 93 (53.1%) N2: 78 (44.6%) N3: 4 (2.3%) |
– | <0.001 | <0.001 |
| Overall stage | I: 456 (49.9%) II: 189 (20.7%) III: 96 (10.5%) IV: 173 (18.9%) |
I: 43 (24.6%) II: 24 (13.7%) III: 45 (25.7%) IV: 63 (36.0%) |
– | <0.001 | <0.001 |
| Stage III–IV | 269/914 (29.4%) | 108 (61.7%) | 0.69 | <0.001 | <0.001 |
| Treatment | Chemo-RT 467 (51.0%) RT alone 410 (44.8%) RT + EGFR inhibitor 38 (4.2%) |
Chemo-RT 116 (66.3%) RT alone 59 (33.7%) |
– | <0.001 | <0.001 |
| Concurrent chemo-RT | 467 (51.0%) | 116 (66.3%) | 0.31 | <0.001 | <0.001 |
| iENE positive | 167 (18.3%) | 60 (34.3%) | 0.37 | <0.001 | <0.001 |
| Acquisition | |||||
| Slice thickness, mm | 2.00 (2.00–2.00) | 3.00 (3.00–3.00) | 5.09 | <0.001 | <0.001 |
| In-plane spacing, mm | 0.976 (0.938–0.976) | 0.977 (0.977–1.367) | 1.50 | <0.001 | <0.001 |
| Axial field of view, mm | 499.7 (480.3–499.7) | 500.0 (500.0–700.0) | 1.50 | <0.001 | <0.001 |
| Subgroup | n (iENE+) | Mean | AUROC (95% CI) | False-negative rate | False-positive rate |
|---|---|---|---|---|---|
| RADCURE held-out set | |||||
| All patients | 163 (25) | 0.18 | 0.913 (0.856–0.959) | 10/25 (40.0%) | 9/138 (6.5%) |
| cN0 | 28 (0) | 0.04 | – | – | 0/28 (0.0%) |
| cN+ | 135 (25) | 0.20 | 0.897 (0.828–0.951) | 10/25 (40.0%) | 9/110 (8.2%) |
| Maastro external cohort | |||||
| All patients | 175 (60) | 0.40 | 0.671 (0.578–0.760) | 23/60 (38.3%) | 33/115 (28.7%) |
| Label modality | |||||
|
MRI |
75 (24) | 0.42 | 0.749 (0.620–0.861) | 6/24 (25.0%) | 14/51 (27.5%) |
|
CT |
21 (8) | 0.48 | 0.769 (0.538–0.952) | 1/8 (12.5%) | 4/13 (30.8%) |
|
PET-CT |
79 (28) | 0.35 | 0.571 (0.414–0.721) | 16/28 (57.1%) | 15/51 (29.4%) |
| Axial field of view | |||||
|
500mm or less |
107 (36) | 0.49 | 0.767 (0.658–0.859) | 6/36 (16.7%) | 28/71 (39.4%) |
|
Above 500mm |
68 (24) | 0.25 | 0.605 (0.446–0.746) | 17/24 (70.8%) | 5/44 (11.4%) |
| Label modality by axial field of view | |||||
|
PET-CT, |
41 (12) | 0.49 | 0.779 (0.583–0.940) | 3/12 (25.0%) | 13/29 (44.8%) |
|
PET-CT, |
38 (16) | 0.21 | 0.511 (0.318–0.705) | 13/16 (81.3%) | 2/22 (9.1%) |
|
MRI or CT, |
66 (24) | 0.49 | 0.769 (0.633–0.884) | 3/24 (12.5%) | 15/42 (35.7%) |
|
MRI or CT, |
30 (8) | 0.30 | 0.756 (0.557–0.920) | 4/8 (50.0%) | 3/22 (13.6%) |
|
All except PET-CT above 500mm |
137 (44) | 0.45 | 0.754 (0.657–0.840) | 10/44 (22.7%) | 31/93 (33.3%) |
| N category | |||||
|
N1 |
93 (29) | 0.34 | 0.592 (0.453–0.730) | 16/29 (55.2%) | 16/64 (25.0%) |
|
N2 |
78 (28) | 0.45 | 0.717 (0.592–0.842) | 7/28 (25.0%) | 17/50 (34.0%) |
|
N3 |
4 (3) | 0.66 | – | 0/3 (0.0%) | 0/1 (0.0%) |
| HPV status | |||||
|
Negative |
74 (23) | 0.41 | 0.706 (0.558–0.840) | 7/23 (30.4%) | 14/51 (27.5%) |
|
Positive |
101 (37) | 0.39 | 0.652 (0.531–0.768) | 16/37 (43.2%) | 19/64 (29.7%) |
| Overall stage | |||||
|
I–II |
67 (21) | 0.35 | 0.619 (0.453–0.776) | 11/21 (52.4%) | 10/46 (21.7%) |
|
III–IV |
108 (39) | 0.43 | 0.701 (0.585–0.815) | 12/39 (30.8%) | 23/69 (33.3%) |
| T category | |||||
|
T1–T2 |
76 (19) | 0.33 | 0.636 (0.472–0.789) | 10/19 (52.6%) | 13/57 (22.8%) |
|
T3–T4 |
99 (41) | 0.45 | 0.669 (0.548–0.779) | 13/41 (31.7%) | 20/58 (34.5%) |
| Sex | |||||
|
Female |
44 (11) | 0.40 | 0.733 (0.523–0.909) | 4/11 (36.4%) | 7/33 (21.2%) |
|
Male |
131 (49) | 0.39 | 0.657 (0.550–0.753) | 19/49 (38.8%) | 26/82 (31.7%) |
| Smoking | |||||
|
Under 10 pack-years |
47 (20) | 0.35 | 0.572 (0.394–0.752) | 11/20 (55.0%) | 7/27 (25.9%) |
|
10 pack-years or more |
122 (36) | 0.41 | 0.715 (0.601–0.824) | 11/36 (30.6%) | 26/86 (30.2%) |
| Treatment | |||||
|
RT alone |
59 (22) | 0.40 | 0.636 (0.479–0.790) | 9/22 (40.9%) | 11/37 (29.7%) |
|
Concurrent chemo-RT |
116 (38) | 0.39 | 0.690 (0.576–0.801) | 14/38 (36.8%) | 22/78 (28.2%) |
| Factor | False negatives | False positives | Score by factor interaction | |||
|---|---|---|---|---|---|---|
| p | q | p | q | p | q | |
| Labelling and acquisition | ||||||
| Label modality (MRI, CT, PET-CT) | 0.016* | 0.049 | 0.961* | 1.000 | 0.028 | 0.056 |
| Axial field of view, 500mm or less vs above | <0.001 | <0.001 | 0.001 | 0.006 | – | – |
| Axial field of view, mm | <0.001 | <0.001 | 0.001 | 0.006 | 0.003 | 0.013 |
| Crop margin, mm | 0.076 | 0.153 | 0.009 | 0.034 | – | – |
| Larynx-centred crop clipped | 0.519 | 0.623 | 1.000 | 1.000 | – | – |
| Slice thickness, 2.5mm or less vs above | n.e. | n.e. | 1.000 | 1.000 | – | – |
| Slice thickness, mm | 1.000 | 1.000 | 0.538 | 0.930 | n.e. | n.e. |
| Clinical | ||||||
| N category (N1, N2, N3) | 0.024* | 0.062 | 0.468* | 0.890 | n.e. | n.e. |
| HPV status | 0.321 | 0.445 | 0.792 | 1.000 | 0.473 | 0.473 |
| Overall stage, I–II vs III–IV | 0.101 | 0.181 | 0.178 | 0.423 | 0.266 | 0.355 |
| T category, T1–T2 vs T3–T4 | 0.121 | 0.198 | 0.166 | 0.423 | – | – |
| Sex | 1.000 | 1.000 | 0.260 | 0.550 | – | – |
| Smoking, under 10 vs 10 or more pack-years | 0.073 | 0.153 | 0.668 | 1.000 | – | – |
| Smoking, pack-years | 0.315 | 0.445 | 0.849 | 1.000 | – | – |
| Concurrent chemo-RT | 0.755 | 0.849 | 0.866 | 1.000 | – | – |
| Age, years | 0.443 | 0.569 | 0.715 | 1.000 | – | – |