S. KimPhD · 2026
Overview
SL 0001

Doctoral thesis · 2026

Reproducible Deep Learning for Head and Neck Radiotherapy

Sejin Kim

Deep learning promises individualized prognosis in head and neck cancer, but the data are not analysis-ready, the models are not comprehensively evaluated, and the outputs are rarely aligned with a decision a clinician actually makes.

Abstract

Deep learning promises individualized prognosis in head and neck cancer, but the data are not analysis-ready, the models are not comprehensively evaluated and characterized, and the outputs are not usually aligned with a decision a clinician actually makes. This thesis addresses these gaps, arguing that clinical deep learning is a data-engineering and evaluation problem at least as much as a modelling problem and that treating it that way is what makes a model deployable.

The first contribution is infrastructure. We curated and publicly released RADCURE: 3,346 head and neck cancer patients treated with definitive radiotherapy, the largest head and neck CT collection on The Cancer Imaging Archive. We published Med-ImageTools, an open-source Python package, which ensures high reproducibility, transparency, and significant time savings for researchers handling medical imaging datasets. Med-ImageTools is the processing engine for all of the projects built on the RADCURE dataset.

The second contribution is evaluation. Three studies investigate what imaging models learn and their implications for clinical deployment. A 12-model prognostic challenge on RADCURE showed the winning model used electronic medical record features plus tumour volume, and that engineered radiomics predictions correlated with tumour volume. A negative-control framework (READII-2-ROQC) destroyed image content nine different ways while preserving volume: a published survival signature’s performance was unchanged, an HPV-status signature drew its signal from the tumour periphery, and an imaging foundation model’s features derived from the background rather than the tumour. A segmentation benchmarking framework (SCARF) across 12 architectures and four blinded expert raters showed that geometric performance and clinical acceptability should not be expected to follow each other.

The third contribution is decision-aligned clinical models. A patient-level classifier of extranodal extension on radiotherapy planning CT, requiring no lymph node segmentation, reached AUROC 0.913 on the held-out test set and 0.671 on an external cohort, and stratified distant control comparably to the expert radiologist whose reads supplied its training labels. Chapter 5 presents preliminary work on Dosarex, a fully automated pipeline that reports per-tooth radiation dose on panoramic radiographs for osteoradionecrosis management.

From Table 2.1

One cohort, every chapter

RADCURE is the public dataset this thesis released, and every study after Chapter 2 draws a subset from it. Each dot below is one patient. Pick a study to see how many patients it used.

3,346of 3,346 patientsAll patients in the public release
Counts are exact. Dot positions are illustrative and do not identify which patients overlap between studies.
Chapter 1Introduction19 min read · 1 figure

How does a machine learning model earn its place in the clinic?

ThesisClinical deep learning is a data-engineering and evaluation problem at least as much as a modelling problem, and treating it that way is what makes a model clinically applicable.

830,000+new head and neck SCC cases worldwide each year
54–71%of HNSCC patients never undergo neck resection, so pathologic ENE is never known
0.64median AUROC of 34 experts reading ENE on preoperative CT

1.1Head and neck squamous cell carcinoma

Head and neck squamous cell carcinoma (HNSCC) arises from the mucosal surfaces of the oral cavity, pharynx and larynx, and its global burden is substantial, with over 830,000 new cases and 430,000 deaths per year, making it the seventh most common cancer worldwide Bray 2018. Approximately 30–40% of patients present with stage I or II disease, which is curable with surgery alone or definitive radiotherapy alone, with long-term survival in "approximately 70 to 90% of patients with early-stage disease." More than 60% present with stage III or IV disease, which "carries a high risk of local recurrence (15 to 40%) and distant metastasis, with poor prognosis (5-year overall survival, <50%)" Chow 2020.

The disease's modern epidemiology can be largely characterized by human papillomavirus (HPV): HPV-positive oropharyngeal carcinoma (OPC) is a biologically and prognostically distinct entity with separate classifications in the 8th edition of the AJCC/UICC staging system Lydiatt 2017. Its markedly better prognosis motivated treatment de-intensification: O'Sullivan and colleagues identified HPV-positive T1–3 N0–2c patients as low-risk candidates for de-intensification (3-year distant control 93%), while cautioning that N2c patients treated with radiotherapy alone had reduced distant control (73% vs 92% with chemoradiation) and are less suited for de-intensification strategies that omit chemotherapy O'Sullivan 2013.

Definitive management of locally advanced disease is multimodal, either with radiotherapy (RT) alone or with concurrent systemic therapy, or transoral surgery with risk-adapted adjuvant treatment. Each escalation in treatment intensity carries a toxicity cost, with trimodality therapy being the costliest. The central tension to manage is that the choice among these pathways is made before treatment, on imaging, under uncertainty.

1.2Extranodal extension (ENE)

Tumour extension through the lymph node capsule into surrounding tissue, namely ENE, is among the most consequential adverse features in head and neck cancer. There are three ways clinicians determine ENE: pathologic ENE (pENE), determined on the surgical specimen and treated as the gold standard; imaging-detected ENE (iENE), determined by a radiologist on pre-treatment imaging; and clinical ENE (cENE), determined via physical examination. While the gold standard has the highest sensitivity, it is inherently limited to patients who undergo neck dissection. It cannot be determined for the majority of definitively irradiated patients and is unavailable for every patient at the moment the initial treatment decision is made. Epidemiological studies reveal that 54-71% of HNSCC patient populations never undergo neck resection Schlichting 2019Zheng 2025.

Prognostic significance. Huang and colleagues showed that iENE carried a multivariable hazard ratio of 3.86 for overall survival Huang 2020. Meta-analysis across 18 studies (n=3,603 HPV+ OPC) pooled the effect at HR 2.64 for overall survival and HR 3.83 for distant control (iENE), versus HR 1.89 and 3.23 respectively for pENE, and neither form predicted locoregional control Benchetrit 2021. Understanding ENE as a marker of distant-spread biology is what later justifies distant control as a stratification endpoint.

Interobserver reliability. In a prospective, blinded international study, 34 experts (11 radiologists, 12 surgeons, 11 radiation oncologists) read preoperative CTs of HPV+ OPC against a pENE ground truth: median AUROC was 0.64 (95% CI 0.44–0.83) with no specialty showing performance beyond chance (AUROC 0.5) Sahin 2025.

Staging history. ENE entered the AJCC/UICC 8th edition (2017/2018) for non-viral HNSCC: any nodal metastasis with clinically overt ENE is N3b, where only unambiguous ENE, as determined by physical examination and supported by radiological evidence, should be present to assign a status of ENE-positive. ENE consideration was excluded for HPV-positive OPC in the 8th-edition Lydiatt 2017.

In the four-centre ICON-N cohort study, Huang and colleagues proposed reclassifying iENE-positive N1 disease as N2 disease and iENE-positive N2 disease as N3 disease for HPV-positive OPC, with iENE carrying an adjusted HR of 2.43 and a grade-dependent gradient (grade 1 AHR 1.73; grade 2, 2.14; grade 3, 3.64) Huang 2025. The updated 9th edition staging manual reflects these findings to include any extent of unequivocal iENE, when declared with high radiologic certainty, as a clinical N category modifier for HPV-positive OPC, while in nasopharynx only advanced-iENE modifies N3, and in non-viral HNSCC, unequivocal iENE is now accepted as a criterion for defining cN3 disease Brierley 2026.

1.3Targeting actionable clinical decisions

The decision point is treatment selection in OPC, and the cost of error is trimodality therapy. ECOG-ACRIN E3311, a phase II trial of transoral surgery followed by risk-adapted adjuvant therapy in HPV-positive OPC, which excluded patients with matted or fixed pathologic adenopathy, assigned patients post-operatively by margins, nodal burden, and ENE extent (≤1mm vs >1mm). Despite the favourable selection, 31% of patients required escalation to chemoradiotherapy post-surgery, and ">1mm extranodal extension" was the dominant trigger, driving 77% of arm-D assignments Ferris 2022. A pre-treatment iENE determination with known operating characteristics could route patients with occult ENE away from primary surgery to avoid trimodality therapy, while preserving surgical de-intensification for patients without it.

The population-level scale of that cost is visible in claims data. Among the 626 resected patients in the SEER–Medicare locoregionally advanced HNSCC cohort, 56.3% received radiotherapy with or without systemic therapy after surgery: 33.1% surgery plus radiotherapy, 23.2% surgery plus systemic therapy and radiotherapy, while only 26.8% were treated with surgery alone Zheng 2025. Escalation after primary surgery is currently the norm rather than the exception, making pre-treatment estimate of nodal risk clinically relevant and actionable.

1.4Radiotherapy planning

Radiotherapy planning workflow. Radiotherapy planning starts with acquiring a planning CT to design the delivery of radiotherapy dose, not to make a diagnosis. Curative radiotherapy for HNSCC conventionally delivers 70 Gy in daily 2 Gy fractions to gross disease, with lower doses to regions at risk of microscopic spread, and is combined with concurrent chemotherapy in most locally advanced cases. With the acquired image, a radiation oncologist contours the targets and organs at risk, which a planner uses to optimize beam parameters against dose objectives. The plan is reviewed by the departmental review board, and treatment is delivered over several weeks with daily image guidance. It is important that targets and organs-at-risk (OARs) contours follow standard nomenclature defined over the years by various consensus guidelines to ensure interoperability Grégoire 2011Mayo 2018. The gross tumour volume (GTV) is the disease that can be demonstrated on imaging and clinical examination, separated in head and neck practice into a primary volume (GTVp) and one or more nodal volumes (GTVn). The planning target volume (PTV) adds a geometric margin for set-up uncertainty. A consensus atlas defines 25 head and neck OARs on CT, which are contoured to minimize dose to preserve healthy, functional organs, and the TG-263 standard governs how they are named Brouwer 2015Mayo 2018.

Dose delivery and normal tissue complication. Intensity modulated radiotherapy (IMRT) varies the fluence across each beam direction, which inverse optimization methods solve for fluence patterns defining concave dose distributions that wrap around targets and spare adjacent normal tissue. In the PARSPORT randomized trial, parotid-sparing IMRT reduced xerostomia from 74% to 38% compared with conventional radiotherapy Nutting 2011. Mandibular osteoradionecrosis is one complication for which an NTCP model has been developed from mandible dose van Dijk 2021.

Planning CT. The planning CT and its accompanying data is the geometric model on which targets and normal tissues are drawn, and the physical model for dose calculation. It differs from a diagnostic neck CT based on its specific purpose. The patient is scanned in the treatment position with a mask and flat bed, the field of view must include the whole external contour for dose calculation, enlarging the in-plane pixel size, and slices are typically 2-3mm thick. CT numbers are converted to electron densities through a scanner-specific calibration curve. Davis and colleagues demonstrated how even minor shifts in CT-numbers can affect calculated dose Davis 2017. Therefore, the imaging acquisition protocols for planning CT are conservative and held fixed within a centre. These realities affect what a model trained on planning imaging data can learn. In machine learning, this can be useful because images from one institution are comparatively homogeneous, but less useful when an existing model is adopted by a new institution.

1.5CT imaging physics

CT reconstructs the X-ray linear attenuation coefficient μ of each voxel from transmission measurements taken at many angles Hounsfield 1973Kalender 2006 and reports it in Hounsfield units (HU), normalized to water = 0 HU. Water and air are 0 and -1000 HU by definition, fat lies near -100 HU, unenhanced soft tissue ranges between roughly 20-80 HU, and cortical bone above 1000 HU. Soft-tissue attenuation tracks electron density and bone/iodine/metal attenuate more strongly through photoelectric absorption Goldman 2007a.

Acquisition and reconstruction. Tube voltage (kVp) sets the X-ray spectrum, which is usually set to 120 kVp for adult head and neck planning scans. Changing kVp can also shift CT numbers and alter HU enough to affect dose calculation Davis 2017. The tube current sets the number of photons, which affects image noise against how well low-contrast structures can be seen Goldman 2007b. Raw projections are turned into images either by filtered back projection (FBP) or by iterative methods. In FBP, the choice of reconstruction kernel trades spatial resolution against noise and iterative algorithms alter the texture of that noise Goldman 2007bWillemink 2019. Slice thickness sets through-plane resolution, with thicker slices being less noisy and averaging more tissue into each voxel. So a structure thinner than the slice, such as a nodal capsule or perinodal fat plane, is captured as a blend of itself and its neighbours. The reconstructed field of view divided by the image matrix sets the in-plane pixel size, which is most commonly set to a 512 x 512 matrix over the approximately 50cm field of a planning scan, yielding 1mm in-plane voxels.

1.6Survival modelling

Outcomes in head and neck oncology are times to an event, whether death, recurrence, or normal tissue complication. For many patients, the event has not occurred when the follow-up period ends. Survival analysis uses these right-censored observations instead of discarding them. The survival function is the probability of remaining event-free beyond a certain time t. The standard non-parametric estimator of the survival function is a Kaplan-Meier model, which formalized a method of leveraging censored data with exact event times (Figure 1.1).

Figure 1.1A toy example of a Kaplan-Meier curve. (1) At t=0, 100% of patients are free of distant failure. (2) One step down indicates one event occurred, so the curve only ever goes down. (3) You can determine what proportion of the samples survive at a certain time point by finding the value of the curve. In this example, at year 2, 75% of patients are free of distant failure.

The Cox proportional hazards model. The Cox-PH model is the standard method for relating patient characteristics to a time-to-event outcome Cox 1972. It describes each patient’s risk at any moment as the baseline risk and the model estimates how much each covariate scales the patient’s risk. The hazard ratio is the magnitude of the scale for each covariate, at which a value of 2 means that patients with the characteristic experience the event at twice the rate of otherwise similar patients without it. Censored patients contribute for as long as they were under observation. The output of the model is a risk score that ranks patients relative to one another, so to yield an absolute probability, Cox models need to be calibrated at each institution.

1.7Radiomics

Radiomics is the high-throughput extraction of quantitative features from medical images to capture tumour phenotype and heterogeneity beyond visual assessment Lambin 2012Gillies 2015. The Image Biomarker Standardization Initiative (IBSI) established reference nomenclature and definitions by fixing the mathematical definition of the most commonly used features Zwanenburg 2020. PyRadiomics is one of the most widely adopted implementations, as it is open-source and often reused by the community van Griethuysen 2017. Features fall into four classes: shape, first-order, texture, and filtered. Shape features are computed based on the segmentation mask alone, without any consideration of intensity values. First-order features describe the histogram of intensities inside the mask. Texture features summarize the spatial arrangement of discretized gray levels through matrices measuring binned intensities. Filtered features repeat the first-order and texture calculations after wavelet or Laplacian-of-Gaussian filtering.

Radiomics signatures. The template of radiomic signatures was set by the four-feature CT signature of Aerts and colleagues, which was trained in lung cancer and remained prognostic in independent lung and head and neck cohorts Aerts 2014. It was later validated in 542 patients with oropharyngeal carcinoma from a different center, and it retained discrimination (C-index 0.628) Leijenaar 2015. A CT signature for HPV status gave AUROCs between 0.70 and 0.80 across validation sets from several centres Leijenaar 2018. Outside head and neck cancer, a radiomics nomogram for nodal metastasis in colorectal cancer kept its discrimination in an independent validation cohort (C-index 0.778) Huang 2016, and a signature of CD8 cell infiltration was associated with survival on immunotherapy on an external cohort Sun 2018. In HPV-related oropharyngeal carcinoma, a radiomic signature predicted distant metastasis with a C-index of 0.670, and tumour volume alone reached 0.674 Kwan 2018. The signature of Aerts and colleagues was itself shown to be a surrogate for volume Welch 2019. Successful external validation shows that a signature is generalizable on new populations, beyond just capturing tumour biology.

1.8Machine learning and deep learning

Supervised learning models learn to predict a label given an input by minimizing a loss over a training set. What matters most is the model’s performance on patients it hasn’t seen during training, so data is partitioned into training set, fine-tuning set to choose hyperparameters, and a held-out test set used once for final evaluations. When the same data are used to select a model and to report its performance, the estimate is optimistic Varma 2006, and leakage between partitions is a recurring failure in medical imaging Varoquaux 2022.

Neural networks and deep learning. A neural network stacks layers of linear transformations and non-linear activation functions and learns its features based on the loss function of the input-label pair, instead of having them defined in advance LeCun 2015. Parameters are fitted by backpropagation and different optimization strategies such as stochastic gradient descent or Adam Kingma 2015. The loss is non-convex, so models with different initializations can converge to different solutions despite sharing identical architectures and ensembles can help reduce those variations. Convolutional neural networks (CNNs) learn visual features through multiple layers of convolution kernels, which are multiplied across the image at every position. Alternating convolutions with downsampling enlarges the receptive field with depth, so early layers learn edges and textures, later layers learn larger patterns and parts, and eventually learn object representations, which a global pooling step followed by a linear classifier converts final feature maps into a class probability Litjens 2017Yamashita 2018.

Evaluation. The AUROC score is the probability that a random positive case scores higher than a random negative one Hanley 1982, and two models tested on the same patients need a paired comparison DeLong 1988. AUPRC is more informative when positives are uncommon, but its baseline equals the prevalence, so it is more informative when evaluating imbalanced datasets Saito 2015. Calibration is the agreement between predicted probabilities and observed frequencies, and a model that discriminates well can still be poorly calibrated in a new cohort Van Calster 2019. Net benefit weighs true positives against false positives at the threshold where a clinician would act Vickers 2006. Geometric metrics such as the Dice Similarity Coefficient (DSC) and Hausdorff Distance (95HD) are used to evaluate the accuracy of segmentation models. Beyond these metrics, the clinical implications of a model are commonly assessed by comparing its predictions with those of clinicians on the same cases, by testing it in an external cohort that reflects the intended population, and ultimately by studying its effect on patient outcomes Park 2018. Although randomized controlled trials are regarded as the gold standard for the last of these, they are not always feasible, and few models have so far reached clinical deployment Kelly 2019.

1.9Deep learning for three-dimensional medical imaging

Clinical 3D volumes are scarce, expensive to label, anisotropic, and encode signal in calibrated intensities rather than natural-image statistics. Dominant strategies of adapting natural imaging methods include 3D convolutions trained from scratch, 2.5D slice-wise approaches, and axial-coronal-sagittal (ACS) convolutions that repurpose ImageNet-pretrained 2D kernels for 3D input.

ACS convolutions are composed of 2D convolution kernels of size K × K, split by output channel into three groups, reshaped into K × K × 1, K × 1 × K and 1 × K × K kernels, and convolved over the axial, coronal and sagittal views of the volume Yang 2021. The three view-based feature maps are concatenated along the channel axis, and no 3D fusion layer is required additionally because the view-based output features will be automatically fused by subsequent convolution layers Yang 2021. Since the kernels are split rather than replicated, the parameter count is exactly that of the 2D model and the converted models could load the 2D weights directly, so any ImageNet-pretrained 2D CNN becomes natively 3D.

The volume confounder. A key theme of our studies is that tumour and nodal volume is a powerful, cheap prognostic signal that dominates imaging models. Welch and colleagues’ re-analysis of the four-feature Aerts radiomic signature refit as "MW2018," achieved an external validation C-index of 0.64. Fitting the same signature using features extracted from images with randomized signal intensities achieved similar performance, with C-index of 0.64 and 0.60 for H&N and lung, respectively. Tumour volume alone reached C-index 0.64, and three of the four signature features correlated strongly with volume. The entirety of the signature was a surrogate for tumour volume, and intensity and texture values did not provide any meaningful signal for prognostication Welch 2019. A subsequent study generalized the diagnosis, with nearly 30% of radiomic features correlated strongly with volume, the first principal component of the full feature set tracked volume at ρ=0.78, and volume-independent features alone could not stratify survival Traverso 2020.

The metric problem. Segmentation quality can be measured in at least a dozen ways, and the choice of measure is not neutral. The Metrics Reloaded consensus, developed by an international consortium through a multi-stage Delphi process, treats validation metrics as proxies for the domain interest and argues that inappropriate metric choice is one reason many artificial intelligence developments in medical imaging do not reach clinical practice Maier-Hein 2024. It identifies three classes of failure: An inappropriate problem category, such as framing a detection task as segmentation so that a missed object is never penalized; Poor metric selection, such as using the Dice similarity coefficient (DSC) where target structures are consistently small relative to the voxel grid; Poor metric application, such as ignoring hierarchical structure when aggregating across patients or institutions. Reinke 2024Maier-Hein 2024. What current literature does not establish is how model performance metrics track clinical utility. It indicates which metric is defensible for a given problem description but does not indicate whether a radiation oncologist would accept the resulting contour. No published study measures the correspondence between geometric metric rank and clinical acceptability directly, according to our best knowledge.

1.10Prior AI work on ENE

Kann and colleagues trained DualNet, a dual-input 3D CNN merging a dimension-preserving and a size-invariant stream of the segmented nodal volume on 270 surgical patients (653 segmented nodes) with node-by-node pathologic correlation, reaching AUROC 0.91 for ENE on held-out nodes ≥1 cm and external validation on two independent cohorts resulted in AUROC 0.84 and 0.90 Kann 2018Kann 2020. However, there are three structural problems with the node-level paradigm.

First, the training population is non-representative. pENE supervision means learning from surgically treated cohorts that differ systematically from the definitively irradiated majority. Since these node-level models are trained with pENE as ground truth, they learn from a surgically treated population that is non-representative of the broader HNSCC cohort, much of which is treated non-surgically Kim 2026. Kann’s study also states its own limitations that there were no cases of ENE identified pathologically when ROI diameter was <10mm in this study, and so it is unclear if the models would generalize to sub-centimeter lymph nodes Kann 2018.

Second, node-level models depend on a node contour at inference, via either expensive clinician time or an upstream segmentation model. Ye and colleagues automated that dependency with nnU-Net auto-segmentation feeding the locked DualNet classifier Ye 2026. Dayan and colleagues also trained a nnU-Net lymph node segmentation model upstream of a radiomics classifier Dayan 2026. While automated segmentations provide scale, it can become an unvalidated dependency; SCARF quantifies how often auto-segmentations are acceptable and how poorly geometric metrics predict it.

Third, aggregation to the patient level is not anchored to an iENE ground truth. Ye’s AI-ENE model predicted at least one AI-ENE node in 70.8% of patients, roughly four times the 15–20% iENE prevalence reported in comparable definitive-RT cohorts Kim 2026. As the cohort is non-operative, the study itself acknowledges the number of false positives and negatives in this study is unknown Ye 2026. The AI-ENE node count is prognostic Ye 2026, but a determination that flags 71% of patients cannot map onto TNM-9, which is defined relative to unequivocal iENE with high radiologic certainty. Without an iENE ground truth to anchor the patient-level aggregation, Ye’s AI-ENE outputs cannot be directly compared to a radiologist's determination and are difficult to integrate into the 9th edition TNM staging framework. Dayan and colleagues’ recent work on a patient-level iENE model achieved AUROC 0.81 against the radiologist reference, with AI-iENE C-indices exceeding the radiologists' own reads (0.79 vs 0.68 for distant control). However, the study is limited by its single-centre design without external validation, only including HPV-positive OPC, segmentation-dependent model design, and incorporating no supervised deep learning training with iENE labels Dayan 2026.

The main gap in the literature is that no published model predicts patient-level iENE from the planning CT every RT patient already receives, with an end-to-end supervised deep learning model, without lymph node segmentation, and with external validation.

1.11The reproducibility problem

The Cancer Imaging Archive is the largest public collection of cancer imaging, ranging across a diverse range of modalities such as CT, MRI, PET, ultrasound, mammography, X-ray, and also connects with multimodal data sources such as clinical, pathology and genomic data Clark 2013. Radiotherapy planning CT is the key imaging modality for making clinical decisions in head and neck cancer cases. However, H&N imaging was not readily available publicly, totaling ~1700 samples before the release of RADCURE, much of which was not easily interoperable due to the lack of adherence to FAIR principles Wilkinson 2016. The data-hungry nature of deep learning methods meant that this effectively limited machine learning research to only a few academic centers with access to large internal clinical databases.

DICOM, the clinical imaging standard, was designed in the 1980s–90s for interoperability among devices, not for analysis Mildenberger 2002. 3D scans are stored slice-by-slice, so researchers must traverse the file hierarchy and stitch series together, and vendor implementations usually differ. A common technical gap for data curation specific for medical imaging research is that one patient may have multiple RTStruct and RTDose files with one imaging acquisition, one RTStruct and RTDose with multiple images, or worst of all, multiple RTStruct and RTDose files with multiple images. Preprocessing curated datasets for machine learning research from public archives such as TCIA with over 140 datasets and rigorous quality assurance processes, still requires manually reorganizing directories and matching radiation therapy structures.

The methodological consequence is that preprocessing choices are often arbitrary and can greatly impact model training and performance but are not transparently disclosed in publications. Preprocessing is a scientific choice presented as a chore. The stakes were stated by Haibe-Kains and colleagues in their response to a prominent closed-pipeline AI study: "the absence of sufficiently documented methods and computer code underlying the study effectively undermines its scientific value … [and] for scientific efforts in which a clinical application is envisioned and human lives would be at stake, we argue that the bar of transparency should be set even higher" Haibe-Kains 2020. Similarly, the joint ESTRO/AAPM guideline formally recommends reproducibility checklists for AI development and warns that even released source code may be insufficient if specific (in-house) coding libraries prevent reproduction Hurkmans 2024.

1.12Thesis objectives by chapter

Clinical deep learning is a data-engineering and evaluation problem at least as much as a modelling problem and treating it that way is what makes a model clinically applicable. We define a model as clinically applicable if its development study is transparent and reproducible, the model can be deployed reliably without manual intervention, and able to inform a specific clinical decision.

Chapter 2: Curate and publicly release the largest head and neck cancer imaging dataset and publish open infrastructure that easily prepares medical imaging datasets for machine learning research. Hypothesis: automated, scripted curation can supersede manual curation in fidelity while being transparent, faster, and reproducible by design.

Chapter 3: Investigate what imaging-based prognostic and segmentation models actually learn, using a multi-team challenge, a configurable negative-control framework, and a model clinical acceptability evaluation framework. Hypothesis: a substantial fraction of published imaging "signal" is attributable to tumour volume or context, and geometric performance metrics do not translate to clinical acceptability.

Chapter 4: Build and externally validate a patient-level iENE classifier on planning CT with no node-segmentation dependency, explicit characterization of volume correlation, and model evaluation anchored to a clinical decision. Hypothesis: a patient-level model can exceed volume and clinical baselines and stratify outcomes comparably to a clinician.

Chapter 5: Extend the methodology from prognosis to supportive care by building a fully automated pipeline that reports radiation dose per tooth on the routine panoramic radiographs, without any manual contouring or operator intervention. Hypothesis: per-tooth dose reporting can be produced unattended from the planning DICOM study to help dentists make better informed and more granular decisions to manage tooth extraction and osteoradionecrosis.

Chapter 2Infrastructure30 min read · 6 figures · 3 tables

From DICOM archives to machine learning ready medical imaging

HypothesisAutomated, scripted curation can supersede manual curation in fidelity while being transparent, faster, and reproducible by design.

3,346patients in RADCURE, the largest head and neck CT collection on TCIA
4downstream chapters that run on one curation engine, Med-ImageTools
1,000core-hours that pre-crawled TCIA databases are expected to save

2.1Chapter introduction

Nothing downstream in our works is possible without analysis-ready data. Med-ImageTools is the preprocessing engine for RADCURE Welch 2024Kim 2025, for the READII-2-ROQC negative-control study Scott 2026, for SCARF’s nine-institution 3,293-patient corpus Marsilla 2026, for the iENE study Kim 2026, and the Dosarex pipeline. Med-ImageTools was leveraged to develop novel survival methods: Deep-CR-MTLR on RADCURE Kim 2021, and beyond the scope of this thesis, used to validate a novel survival modelling method, FastCPH, on an external head and neck dataset Yang 2022. Four downstream chapters depend on one package. That is the argument for treating infrastructure as a scientific contribution rather than as preamble: when a single curation engine underlies the data release (Chapter 2), all three evaluation studies (Chapter 3), and the clinical models (Chapter 4 + 5), the transparency and correctness of that engine become scientific properties of everything built on it.

This chapter presents the two halves of that foundation: the largest public head and neck dataset curated and released, RADCURE (Ch.2.2), and the software used to process it, Med-ImageTools (Ch.2.3).

2.2RADCURE: An open-source head and neck cancer CT dataset for clinical radiation therapy insights

Welch ML*, Kim S*, Hope AJ, Huang SH, Lu Z, Marsilla J, Kazmierski M, Rey-McIntyre K, Patel T, O'Sullivan B, Waldron J, Bratman S, Haibe-Kains B, Tadic T; Princess Margaret Head and Neck Site Group. Med Phys. 2024 Apr;51(4):3101-3109

Mattea L. Welch and Sejin Kim contributed equally to this work.

2.2.1Introduction

In the realm of healthcare research, there is a growing emphasis on the development of automated pipelines and computational analysis of patient medical data. Specifically, in cancer care, volumetric images are abundant and routinely collected at multiple time points during a patient’s treatment Gillies 2015. Recent studies have demonstrated the application of computational analysis and machine learning techniques to retrospective cancer imaging data. However, the often limited size of the datasets used can result in studies with inconclusive results Morin 2018. For robust analysis, particularly in diseases with complex or heterogeneous manifestations, large datasets are critical to ensure comprehensive coverage of all disease phenotypes.

Each type of cancer introduces distinct challenges in diagnosis, prognosis, and treatment strategy formulation. These challenges are further amplified when applying machine learning techniques when adequate representation of disease phenotypes within the datasets is absent. Head and neck cancer (HNC) is an example of a highly heterogeneous disease Lydiatt 2017 that encompasses 13 different disease sites, each impacted by the inherently complicated anatomy of the head and neck. Additionally, factors such as human papillomavirus (HPV) status can impact primary and secondary endpoints such as overall survival and distant metastasis. These complexities present formidable challenges for computational analyses and machine learning frameworks, which could potentially be mitigated by leveraging larger datasets.

Several research groups have employed extensive HNC datasets to glean new clinical insights. Imaging biomarkers or radiomic signatures have been derived using hand-engineered imaging features from images and contours to forecast patient outcomes, often serving as a foundational comparison for prognostic imaging tasks Aerts 2014Vallières 2017. Despite the large dimensionality of radiomic features that attempt to capture various complexities of the tumour from imaging, there is evidence suggesting that these radiomics features are prone to being confounded by tumour volume Welch 2019. Deep learning models aim to overcome this limitation by further abstracting radiomic features beyond hand-engineered feature definitions. These methods have been used for prognostic tasks involving the prediction of extranodal extension Kann 2018, as well as the automation of clinical tasks such as organs-at-risk segmentation Nikolov 2021Oreiller 2022. The success of these studies, and their resulting contributions to both academic and clinical knowledge, is reliant on large, highly curated datasets.

Open-source data repositories, such as The Cancer Imaging Archive (TCIA) Clark 2013, enhance the transparency and rigor of research, granting access to substantial datasets that may otherwise be inaccessible to individual researchers or institutions. These repositories are instrumental in promoting reproducible science and the continuous evaluation of published research. In this chapter, we introduce RADCURE Clark 2013Kazmierski 2023, a single-institution dataset comprised of 3,346 HNC computed tomography (CT) images with associated radiotherapy (RT) contours and outcomes data that is available on TCIA. RADCURE, with its significant patient count, not only reflects the diverse presentation of HNC patients treated at our institution but also contains the variability necessary to characterize this heterogenous disease site thoroughly. The curation and dissemination of RADCURE aims to stimulate further research and foster novel scientific inquiries in the realm of medical image analysis.

2.2.2Acquisition and Validation Methods

RADCURE comprises data for 3,346 HNC patients treated at the Princess Margaret Cancer Centre with definitive radiation therapy (RT) or chemoradiation between 2005 and 2017. The collection of this dataset for research purposes was approved by the institutional Research Ethics Board (REB # 17-5871). RADCURE is the largest of its kind to be made openly available on TCIA (Figure 2.1), and contains important imaging, clinical, demographic and treatment information data (Figure 2.2, Supp.Table 1).

Figure 2.1 Comparison of the types of clinical imaging modalities contained in open-source head and neck datasets available on The Cancer Imaging Archive Clark 2013. The total number of patients contained in the datasets are denoted above the dataset’s associated bars. The following datasets are included: AAPM-RT-MAC Cardenas 2020, Cetuximab (RTOG 0522) Ang 2014, CPTAC-HNSCC, HEAD-NECK-RADIOMICS-HN1 Wee 2019, QIN-HEADNECK Beichel 2015, Head-Neck-PET-CT Vallières 2017, TCGA-HNSC Zuley 2016, HNSCC Grossberg 2018, and RADCURE.

Imaging and Contour Information. For each patient, a single RT planning CT image is provided along with the corresponding normal and non-normal tissue contours. Contours are included for the primary gross-tumour-volume (GTVp), relevant gross lymph nodes, and organs-at-risk (OAR). CTs were acquired on Toshiba, GE, and Philips machines. On average, pixel spacing was 0.96mm, with an in-plane-resolution of 512 by 512. Average slice thickness was 2.20mm and the average number of slices was 183. Contrast was administered during CT simulation as per institutional clinical guidelines. Overall, 61.5% of patients were imaged with an administered contrast agent, and this variable is provided in the associated clinical datasheet to allow dataset users to select studies with/without contrast enhancement as needed for analysis.

The GTVp was delineated according to Princess Margaret Cancer Centre’s Head and Neck Site Group’s contouring guidelines. The majority of contour sets were peer-reviewed at weekly site group RT quality assurance rounds.

Figure 2.2 Heat maps showing the inclusion and completeness of data types across openly available datasets on TCIA with comparable imaging to RADCURE. Head-Neck-Radiomics-HN1, HNSCC, Head-Neck-PET-CT.

Demographic, Clinical and Treatment Information. Clinical data, including demographics, staging, treatment, and outcomes, were prospectively assembled via an in-house prospective database (“Bioclinical Anthology of Outcomes in Head and Neck Cancer”) where outcome data was collected at point-of-care Wong 2010. Demographic data includes age at the time of diagnosis and patient sex. Treatment data includes prescribed radiation dose and status of systemic therapy. Clinical data includes the disease subsite, staging according to the 7th edition of the American Joint Committee on Cancer (AJCC) staging manual (includes T, N, M and overall stage), ECOG (Eastern Cooperative Oncology Group) performance status (i.e., patient’s level of daily functioning as it relates to daily activity, ability to care for themselves, etc.), feeding tube presence, and p16 status used as a marker indicating human papillomavirus (HPV) status. Supplementary Table 1 includes variable distributions for select features of the dataset.

Outcome Data. Binarized 2-year survival and continuous overall survival in months (duration of survival from diagnosis date to death or censoring) are provided for all patients along with cause of death, and time to local, regional, or distant metastasis (Figure 2.3). All data is up to date as of November 2021.

Figure 2.3Event information for patients of RADCURE. Kaplan-Meier curves show time to event information for: a) Local Failure, b) Regional Failure, and c) Distant Failure. Length of follow-up for patients are shown in subplot d). Patient status and Cause of Death pie charts show the percentage of patients in the dataset who are still alive, as well as the cause of death for patients. 

Data Extraction and Translation. An in-house data mining and processing system MIRA (University Health Network, Toronto, Canada) was used to extract and translate RADCURE imaging and structure set data from our institution’s radiation treatment planning and oncology information systems. The input to the data extraction was a set of patient identifiers, radiation treatment start dates and radiation dose-fractionations provided from our institution’s HNC anthology (Figure 2.4).

The mining platform uses a series of data comparisons to select treatment planning files corresponding to delivered plans in our oncology information system. The origin of the CT simulation and contour data was the external beam radiation treatment planning system (TPS) Pinnacle (Philips Radiation Oncology Systems, Fitchburg, WI). The primary CT dataset used for treatment planning is stored in the DICOM format within a patient directory for each radiation treatment plan in the Pinnacle file store. The treatment planning structure set, treatment beam descriptions and numerous dose files corresponding to plan/beam/control-point dose distributions are also stored in this directory in Pinnacle-specific file formats. The treatment beam file is parsed and used in the data validation, but the file is not extracted or translated into a DICOM RT-Plan due to missing beam parameters (e.g. total beam MU). The dose files were not used in the extraction.

Given a patient identifier for data extraction, MIRA locates the patient directory and validates the treatment planning data contained within through a series of heuristics that ensure 1) the radiation dose prescription of the treatment plan matches the input dose-fractionation, 2) the treatment plan has been delivered and recorded in our oncology information system Mosaiq (Elekta, Stockholm, Sweden) and 3) the first delivered fraction was within three days of the input start date recorded in the HNC anthology. Out of the 4130 patients submitted as inputs to the extraction, approximately 3300 matched a single unique treatment plan. The remaining cases, which were abandoned, either matched multiple treatment plans (e.g., multiple ambiguous copies of a treatment plan with potential differences in contour data), or more commonly, did not match any treatment plan (e.g., due to errors in input data, delays to treatment start that resulted in date discrepancies with the input filter, planned split treatment courses that resulted in radiation dose discrepancies with the input filter, etc.).

Figure 2.4Schematic of the in-house data mining system, MIRA. RT: Radiation Therapy, DICOM: Digital Imaging and Communications in Medicine, CT: Computed Tomography

Upon validation, the DICOM CT image was extracted from Pinnacle and the contour file was translated to a DICOM RT-STRUCT. All RT-STRUCT contours were further validated by ensuring each contour was located on a CT image slice and fully contained within the image bounding box. Manual verification of a subset of the extracted CT images and RT-STRUCT contours was performed by visual inspection and comparison to CT images and RT-STRUCT objects manually exported from the Pinnacle TPS. All extracted and translated data were transferred to a secure storage location on a computational cluster within our institution.

Data Curation. After RADCURE was placed on our institutional computational cluster, additional validation and filtering was completed using both electronic medical records (EMR) and DICOM data.

We filtered EMR data to only include patients with M0 disease and with more than two years of follow-up if the patient was still alive at last follow-up. We performed minimal pre-processing on the EMR data but did perform text case normalization of disease sites.

We further filtered based on the patient DICOM CT Image and RT-STRUCT. Verification of these files included the ability to successfully load/open the files using SimpleITK Lowekamp 2013. The RT-STRUCT file also needed to contain a non-empty gross-tumour-volume, where GTV, GTVp, and high-risk target volume (HTV) were acceptable naming standards. It was assumed, based on institutional guidelines, that this contour did not contain lymph nodes.

RT-STRUCT files were curated to contain the patient’s primary gross tumour volume and organ-at-risk contours. All region of interest (ROI) names were standardized according to AAPM TG-263 nomenclature guidelines Mayo 2018, with an adaptation for nodal targets. All nodal targets appear in RT-STRUCT files as GTVn_[X], where X is the original nomenclature used for that ROI. At our center, all nodes are labeled based on the cervical neck level Grégoire 2014, and if multiple nodes exist an additional roman numeral was added to enumerate the nodes within the level, e.g. the third node in neck level 2B would have a name GTVn_iii2B.

This curation was largely scripted using functionality found in the python package Med-ImageTools Kim 2025. This automated curation process was chosen over human curation to increase transparency and provenance of the data.

2.2.3Data Format and Usage Notes

Data Format. All imaging and structure set data are provided in standard DICOM CT and RT-STRUCT formats, respectively. All data were de-identified and uploaded to TCIA using their standard pipelines. De-identification is a multi-stage process utilizing layers of CTP (Clinical Trials Protocol) clients. Details of this process can be found in the TCIA documentation Clark 2013. Briefly, an ID-mapper file is provided to the CTP that maps institutional patientIDs to a TCIA ID. Next, a burned-in pixel filter checks specific DICOM tags that may suggest PHI on an image – thereby preventing transmission to TCIA. Finally, all images are submitted to TCIA using Aspera enabled high speed transfers that utilize Fast Adaptive and Secure Protocols (FASP). This process is enabled by a script that removes or blanks standard tags known to contain PHI, offsets DICOM header dates and generates unique identifiers (UID) that include TCIA-side embedded root IDs.

Data Overlap with Previous TCIA Data. It is important to note that although RADCURE is a cohort of 3,346 patients, 606 of these patients were previously released on TCIA as the OPC-Radiomics database. These 606 OPC-Radiomics patients have been consolidated with the newly released 2,740 patients and are contained in a single database named RADCURE. The OPC-Radiomics database has been removed from TCIA. However, an ID mapping sheet between OPC-Radiomics and RADCURE ID names is available on TCIA.

The patients from OPC-Radiomics contain RT-STRUCT files that have undergone standardization of contour names consistent with the new 2,740 patients. Additionally, the endpoints for the OPC-Radiomics patients were updated during the curation of the clinical datasheet for the newly published patients. It is recommended that the new clinical datasheet be used for all future use of the OPC-Radiomics, and that previous work utilizing these 606 patients be updated if necessary.

2.2.4Discussion

The RADCURE dataset, with its comprehensive collection of patient images, offers substantial opportunities for both academic and clinical research. It stands as a preeminent single-institution imaging dataset, boasting roughly 3.5 times the patient imaging data compared to other HNC datasets on TCIA. This rich amalgamation of imaging, clinical, demographic, and treatment data positions RADCURE as a prime resource for a host of image analysis research initiatives.

CT images provide structural information of patient anatomy such as the size, shape and relative location of tumours, lymph nodes and critical organs. Additionally, CT images can be used to quantify tissue density heterogeneity Lubner 2017, identify vascular invasion of tumours Zhao 2022 and characterize extracapsular extension (e.g. of cancerous lymph nodes) Carlton 2017. These anatomical and biological features motivate the potential role of CT combined with machine learning for prognostication for head and neck cancer, which may yet uncover subtle image features that have novel prognostic value. As demonstrated by the previous work done with RADCURE Reiazi 2021Arrowsmith 2020Kim 2023, or with other similar datasets, potential studies could include outcome prediction with appropriate baseline clinical comparators or analysis of the relationships between provided clinical, demographic and treatment information and imaging features. Notably, deep learning techniques require more data than traditional machine learning techniques and are highly susceptible to over-fitting Mateus 2023. As such, by providing a larger dataset of CT images (two to tenfold) than used in previous studies that demonstrate promising results, we believe the RADCURE dataset has the potential to power future work that may yield new and more generalizable models.

Furthermore, RADCURE also contains variability in image acquisition parameters despite being collected at a single institution. This variability will allow researchers to gain a better understanding of the impact of these parameters on imaging features. Other imaging analysis research projects that will benefit from RADCURE include quality assurance projects. The dataset has been highly curated, but there are opportunities for research pertaining to artifact detection, DICOM metadata analysis, and the relation of these artifacts to radiomic features, or other intermediate or end point data.

Although the size of RADCURE provides many opportunities for academic and clinical research communities, it does have limitations. A significant constraint is its reliance on the 7th edition of the AJCC staging manual for clinical staging, rendering the clinical data outdated compared to the 8th edition. This limitation is not unique to RADCURE but is prevalent across open datasets, including those for HNC on TCIA. Consequently, any model developed using RADCURE must be approached with caution if it is to be applied to patient cohorts staged under the new AJCC protocols.

Additionally, RADCURE is missing information required for a complete view of a patient’s disease. For instance, RADCURE contains a limited number of clinical, demographic and treatment features. Compared to other HNC datasets on TCIA it is a comprehensive list, but variables such as histology and feeding tube status are limited and may lead to biased results. We plan to include additional clinical and treatment features as they become available. However, certain demographic variables (e.g., race and income) are not collected at our institution. Chart information is also not available for these patients. This includes information like chemotherapy dose and toxicity measurements, which are required for complete clinical interpretation of the data. Clinical and planning target volumes and treatment planning dose data have also been excluded from this dataset, limiting the ability to study institutional treatment guidelines or prognostic modeling leveraging dosimetric factors.

RADCURE consists exclusively of CT images collected for radiation treatment planning. This is in contrast to other publicly available head and neck datasets that contain multimodal images, such as PET (Figure 2.2). These additional imaging modalities may provide important quantitative information, such as standardized uptake values or tissue relaxation time, which are related to tissue function and could improve our understanding of a patient’s clinical indicators and their disease characteristics beyond the anatomical and density information provided by CT Bogowicz 2017. However, many questions still remain regarding clinical utility Bogowicz 2019, reproducibility Mateus 2023, and the biological meaning that drives prognostic modeling based on clinical images Tomaszewski 2021.

2.2.5How RADCURE enables the rest of this thesis

Table 2.1RADCURE subsets used across our studies.
Project Subset definition n
Full public release (Ch. 2) all 3,346
Survival Modelling (Ch.3.2-3.3) M0, 2Y+ follow-up, no prior surgery, GTVp available 2,552
READII-2-ROQC (Ch.3.4) successfully processed GTVp 2,994
SCARF (Ch.3.5) all 19 essential OARs delineated 582
iENE (Ch. 4) primary OPC with iENE labels 915
Dosarex (Ch. 5) RADCURE-CT / -DOSE / -DX 885

2.3Med-ImageTools: An open-source Python package for robust data processing pipelines and curating medical imaging data

Kim S, Kazmierski M, Qu K, Peoples J, Nakano M, Ramanathan V, Marsilla J, Welch M, Simpson A, Haibe-Kains B. Med-ImageTools: An open-source Python package for robust data processing pipelines and curating medical imaging data. F1000Research. 2025 Feb 7;12:118.

2.3.1Introduction

Radiology is a powerful modality of data for clinical work, giving clinicians the ability to see the inner workings of the human body, that cannot be seen from the outside Brant 2012. They can inspect in 2D or 3D, the anatomy surrounding the disease, enabling key information to make life-altering clinical decisions. While regular images taken on cameras or phones are stored in a variety of accessible formats, medical images are encoded in the Digital Imaging and Communications in Medicine (DICOM) standard file format Mildenberger 2002.

The DICOM standard was developed in the 1980s due to the increasing need for an interoperable standard for 3D medical images across various manufacturers Mildenberger 2002. A key feature of DICOM is the plethora of metadata fields that store information beyond imaging data, such as patient information, clinical variables, and acquisition parameters. As modern medical practice evolved over the years, the DICOM standard has grown to accommodate more metadata fields and encompass new imaging modalities or therapy information Mildenberger 2002. This type of data format is unsuitable for imaging analysis as the relevant voxel array must be manually accessed through DICOM hierarchy Mildenberger 2002. Since 3D scans are acquired on a slice-by-slice basis, researchers must stitch together data from multiple files to create one 3D image, adding delays caused by disk reads and consolidation processes Mildenberger 2002.

Specialties that rigorously use imaging data are heavily reliant on DICOM, one of which is radiation oncology. Images are used along every step of the clinical workflow: from deriving a precise diagnosis, to designing personalized radiation therapy plans, and delivering each radiation dose with the appropriate alignment and orientation with brief scans. While the defined standard serves as a good guideline, each manufacturer has slightly different implementations. This is especially the case for DICOM-RT (radiotherapy), a subset of modalities for communicating radiotherapy data Mildenberger 2002. The DICOM-RT standard includes additional modalities such as RTStruct for contour data, and RTDose for radiotherapy dose maps and dose-volume histograms (DVH). While the broad adoption of the DICOM standard to accommodate for various use cases has allowed it to become the de facto standard for encoding, storing, and transferring of medical images, its comprehensive nature has made it difficult for researchers to navigate for the purposes of imaging projects.

2.3.2Current workflows

The Cancer Imaging Archive (TCIA) is one of the largest public repositories of DICOM images available, with over 140 datasets consisting of more than 60,000 patients Clark 2013. The datasets undergo a quality assurance process to ensure the recorded clinical variables are coherent and the DICOM files are not missing any important metadata fields. These stringent processes and infrastructure have allowed TCIA to become one of the most comprehensive repositories for biomedical imaging datasets, inviting researchers from different fields to explore new ideas and methods on high quality datasets.

While the underlying data and its annotations are of clinical quality, processing the dataset for subsequent analysis requires a non-trivial amount of effort: manually reorganizing directories and matching radiation therapy structures (RTStruct), referred to as DICOM-RT contours, and radiation therapy plans (RTDose/RTPlan) to its corresponding images Law 2009. This is partly due to the inherently complex nature of clinical datasets, as data is collected on the basis of need and iterative improvements, not structured scientific inquiries. It is also sometimes due to the lack of familiarity from machine learning (ML) and artificial intelligence (AI) researchers in handling the DICOM files for their analytical pipelines. Typical AI imaging datasets have pairwise associations of one image to a single ground-truth label Deng 2009. However, one patient in clinical datasets may have multiple RTStruct and RTDose files with one imaging acquisition, one RTStruct and RTDose with multiple images, or worst of all, multiple RTStruct and RTDose files with multiple images Vallières 2017. In any of these cases, the directories are not always intuitively structured to help researchers understand which files correspond with another.

Once researchers have successfully curated the dataset into an organized structure for analysis, in order to process the raw dataset into analysis-ready format, they must choose from a variety of processing parameters, ranging from voxel spacing, RTStruct name parsing, and Hounsfield unit (HU) window levels, based on the design of their analysis. While these implicit decisions for image processing are often arbitrary, they can greatly impact model training and performance, but are not transparently disclosed in publications Sabottke 2020. This leads to the difficulty of reproducibility of medical deep learning research, adding another deterrence to clinical adoption.

Furthermore, there are a limited number of software packages that researchers can use to quickly parse DICOM-RT files into analysis-ready arrays. Chief among those, SlicerRT Pinter 2012, an extension of 3DSlicer Pieper 2004, an open-source DICOM visualization tool, has been widely used by the medical imaging community. Despite its broad adoption, batch data processing with Slicer requires custom scripting in Python, to be executed in the Slicer ecosystem. Rather than simply installing a package within their Python environment, users must install the Slicer application and add any other dependencies, not provided by Slicer, into the application environment. As a result, machine learning projects relying on Python for data preprocessing will have their code fragmented across multiple environments–the Slicer environment for data processing, and another Python environment for data analysis and machine learning. RT-Utils is a lightweight, open-source Python package designed to handle RTStruct files with relative ease and simplicity, allowing users to easily export contours into segmentation masks in arrays. However, the functionalities of RT-Utils are limited to the RTStruct modality. PlatiPy is a recent processing library and analysis toolkit for medical imaging, mainly designed for the context of radiation therapy. It features a comprehensive set of image manipulation functions such as registration and atlas-based segmentation methods, allowing researchers the flexibility to process imaging data into any format they need. However, PlatiPy does not solve the inherent complexity of clinical datasets, and researchers must spend hours reorganizing the data into a structured set of samples and labels. The current landscape of open-source medical imaging tools highlights the need for a native Python package that can parse large DICOM/DICOM-RT datasets to an analysis-ready format for ML/AI development in a consistent, reproducible workflow.

Table 2.2Comparison of existing medical imaging processing packages and their features. RTSTRUCTs: DICOM-RT Contours; RTDOSEs: DICOM-RT Dose; CT: Computed Tomography; MRI: Magnetic Resonance Imaging; NIfTI: Neuroimaging Informatics Technology Initiative; NRRD: Nearly raw raster data; DICOM: Digital Imaging and Communications in Medicine.
Feature 3DSlicer
+ SlicerRT
RT-Utils PlatiPy PyDicer Med-ImageTools
Native Python interface ● ● ● ●
Command-line interface ●
Handles RTSTRUCTs ● ● ● ● ●
Handles RTDOSEs ● ● ● ●
Handles images (CT/MRI) ● ● ● ●
Built-in image transformations ● ● ●
Exports to analysis-ready NIfTI/NRRD ● ● ● ●
Image registration ● ●
Built-in bulk processing of entire datasets ●
Automatic parsing of DICOM metadata ● ●

To address the limitations of the current software packages used to process medical images, we developed Med-ImageTools, a new Python package designed to help researchers transform complex medical datasets into analysis-ready format with few lines of code. It is also focused on helping researchers develop transparent and reproducible medical image processing pipelines by addressing most of the boilerplate code required for image transformations and processing parallelization. While Med-ImageTools has many modular functions for image, contour, and dose input/output (IO) built on popular frameworks such as SimpleITK, TorchIO and PyDicom, such functionalities are redundant and available in other open-source packages as well. We have tailored our core features towards broader use cases and development workflows, instead of modality or disease type specific workflows, such as BIDS Gorgolewski 2016. Our main contribution is in the development of AutoPipeline and will mainly discuss its functionalities and implementation.

2.3.3Methods

AutoPipeline is the main feature of Med-ImageTools that allows users to easily process raw DICOM clinical datasets into analysis-ready Nrrd or NIfTI files, which are commonly used file formats for 3D volumetric data. It is interfaced using the command line, so the user only needs to submit a single command into the terminal to execute the three core steps in the AutoPipeline process (Figure 2.5):

  1. Crawl: The crawler opens every DICOM file in the dataset using Pydicom, indexing important metadata, such as unique identifiers, modality information, and references to other modalities. This produces a database of every unique image and DICOM-RT modality.

  2. Connect: In this step, each patient’s indices of unique files of different modalities are connected to form one coherent sample. There are various heuristics the user may choose to connect samples. The default option is through DICOM metadata, as datasets derived from clinical practice are expected to have corresponding metadata that references unique identifiers of the parent image or RTPlan. Alternative heuristics allow users to deal with anomalies with corrupted or missing metadata.

  3. Process: All identified samples are processed according to imaging and transformation parameters defined by the user. The user can configure parameters such as the pixel spacing in mm(s), which specific modalities to process, the number of cores they want to use for multiprocessing, and define nnU-Net specific flags as well. The images are manipulated using SimpleITK without requiring any user intervention.

Figure 2.5 Overview of Med-ImageTools features. Raw datasets are indexed by the Crawler module and automatically processed by AutoPipeline. DICOM: Digital Imaging and Communications in Medicine; RTSTRUCTs: DICOM-RT Contours; PET: Positron emission tomography. NIfTI: Neuroimaging Informatics Technology Initiative; CSV: Comma-separated values.

The AutoPipeline feature can be directly interfaced once Med-ImageTools is installed. To install Med-ImageTools, the recommended method is via the PyPI package repository in a virtual environment. Running the ‘pip install med-imagetools ’ command will install the latest version of Med-ImageTools and its associated dependencies defined by the requirements.txt file. Now, whenever the user is in the virtual environment where Med-ImageTools is installed, they can directly interact with the AutoPipeline feature in the command line. The simplest way to use it is through ‘autopipeline input_directory output_directory’. This will automatically process the dataset located in ‘input_directory’ and process them at ‘output_directory’ using the default parameters. Med-ImageTools will generate files that are not analysis-ready images, such as the autogenerated ‘Dataset Index’ (Figure 2.5), and store them in a folder named “.imgtools” at the path of the ‘input_directory’. This is to ensure a convenient user experience and intuitive folder structure by hiding extraneous components. An extended tutorial of AutoPipeline and all its associated parameters are available on our documentation page. At the present time, there are no minimum system requirements for Med-ImageTools as it will run regardless of number of processor cores or memory (RAM). However, if the researcher can leverage greater number of cores and RAM, it will allow the AutoPipeline to be parallelized and process the data faster.

As the crawl and process steps are computationally intensive, all steps in AutoPipeline are automatically parallelized using the joblib backend to efficiently leverage all available computational resources. While the output of the AutoPipeline processing can result in terabytes of images, the crawl is limited to a few kilobytes of a metadata database, making it an ideal asset to share with other researchers as a detailed descriptor of a medical imaging dataset. We therefore propose to attach the crawled metadata spreadsheet to large TCIA datasets to allow Med-ImageTools users to process large datasets much faster and more efficiently. These databases are expected to save up to 1000 core-hours of crawling per dataset, accumulating over 2000 core-hours of computation saved per user. By standardizing a commonly repeated imaging processing pipeline into a single unified package, we hope to improve the reproducibility and transparency of future medical imaging research.

2.3.4Use Cases

We showcase the value of the AutoPipeline implemented in Med-ImageTools v1.0.0 for processing three medical imaging datasets, namely Pancreatic-CT-CBCT-SEG from TCIA, a private liver metastasis dataset and a pre-release extraction of RADCURE, in order of complexity and sizes. In each use case, we initially describe the process.

Figure 2.6a) Time taken to process the Pancreatic-CT-CBCT-SEG dataset with (Pre-crawl) and without (Default) the pre-crawled databases. b) Amount of core-hours saved by using pre-crawled databases across various public TCIA datasets. c) Time taken to process the liver metastasis dataset manually vs AutoPipeline. d) Time taken to process the RADCURE dataset manually vs AutoPipeline.

Using pre-crawled datasets on the Pancreatic Cone-beam Computed Tomography (CBCT)

40 patients with abdominal CBCT scans and their associated contours of regions of interest and other organs, publicly available on TCIA

The Pancreatic-CT-CBCT-SEG dataset Hong 2022 was processed twice using AutoPipeline: once from scratch, and once using the pre-crawled dataset, available on the tcia-crawls branch of Med-ImageTools. Processing from scratch, the dataset took 10.77 core-hours (10:46), whereas using a pre-crawled database allowed the processing to finish in 9.14 core-hours (9:08) (Figure 2.6a). The pre-crawled database reduced processing time by 1.63 core-hours, representing an 18% increase in total processing speed or 2 minutes 27 seconds per patient. The time saved from pre-crawled databases is not a substantial quantity for datasets with less than 100 patients. However, when scaled up to larger TCIA datasets such as OPC-Radiomics (n=606) Kwan 2019 and NLST (n=26254) NLST 2011, it can save researchers 24.7 core-hours and 1072 core-hours, respectively (Figure 2.6b). The resources saved are reported in core-hours to allow a hardware-agnostic estimation of time and cost savings. While it may vary depending on the research infrastructure utilized, these databases can result in significant savings in billing.

Comparing manual vs automatic processing of the liver metastasis dataset

97 patients with abdominal CT scans and their associated contours of liver and gross tumour volumes (GTV), data access described in data availability section below.

The liver metastasis dataset was processed using the Slicer API to export a CT scan along with segmentations of the liver and GTVs for each patient. In the initial DICOM dataset, each patient had a single RTSTRUCT file along with one or more CT series, one of which was referenced by the RTSTRUCT. The first step of the process was to load the entire DICOM dataset into the Slicer DICOM database via the graphical user interface (GUI), to make the data available inside the Slicer scripting environment. Then, we wrote a script to export an initial set of candidate segmentations for the liver and GTVs for each patient, along with the referenced CT scan. This script leveraged the Slicer API to identify the CT series that was referenced by the patient’s RTSTRUCT and used an ad hoc string filtering function to identify candidate segmentations. Finally, we iteratively refined the set of exported RTSTRUCT contours on a patient-by-patient basis, based on visual checking, and physician feedback. Although this step was time-consuming, there is, at present, no substitute for manual verification to ensure data quality and correctness. On the other hand, the initial database construction and export script using the Slicer API achieved results roughly analogous to the automatic output of AutoPipeline. The export script is approximately 170 lines long and took 7.5 hours to run on the whole dataset–this script is available on our GitHub repository. In contrast, on the same 6-core machine (16GB RAM, Windows 10), AutoPipeline took only 2.3 hours with 1 command line, mainly accelerated by parallelization (Figure 2.6c). The authors involved in validating Med-ImageTools’ effectiveness on this private dataset had no active involvement in the development of the package before its application. This highlights the package’s robustness on unseen data and its potential utility for multi-centre collaborations to ensure consistent processing. One use case might be to enable federated learning platforms to automatically process each node’s datasets without requiring any user intervention.

Comparing manual vs automatic processing of the RADCURE dataset

3,219 patients with head and neck CT scans and their associated contours of organs at risk (OAR) for radiotherapy (pre-release extraction; the public TCIA release contains 3,346 patients).

At the time of this benchmark, the RADCURE extraction comprised 3,219 head and neck cancer patients and their radiotherapy planning data Welch 2024. The data arrived as two separately structured exports, meaning the directories and DICOM metadata were organized differently. The directories from each system were restructured using general heuristics, and any abnormal cases were flagged and manually organized. We used SimpleITK and PyDicom to extract the imaging and contour data from the DICOM files, which underwent a similar iterative process as the liver metastatic dataset. The script is over 1000 lines long and takes 30-40 hours to run on the whole dataset using a single core–this script is available on our GitHub repository. AutoPipeline scales dramatically based on the number of cores available, which enables the entire dataset to be processed in 40 minutes using 32 cores, automatically managing the directories from different systems and extracting the contours (Figure 2.6d). These results demonstrate Med-ImageTools’ design does not bottleneck any multiprocessing backends and brings meaningful acceleration on very large datasets, such as RADCURE.

One caveat of these comparisons is that the iterative process of filtering appropriate contours, which can add weeks to months of cooperation between the researchers and the physicians, was already conducted in the original processing steps. Various data cleaning steps that require human intervention, such as sorting contour names or selecting specific subseries acquisitions, cannot be fully automated for the foreseeable future. The Med-ImageTools team aims to add features to the package that will assist researchers in these steps, such as adding a flag to visualize all unique contours without requiring code, adding subseries detection to the crawler, and publishing a set of regular expressions (regex) that can be used to automatically choose contours from prominent head and neck datasets on TCIA. Also, these comparisons do not take into account the time it takes for researchers to develop the manual processing scripts. Hence, the actual amount of time saved for the researcher may be greater than the reported times.

2.3.5Discussion

Although ML and AI promise to revolutionize the way we leverage medical imaging data for improving care, they require large datasets to train computational models that can be implemented in clinical practice. However, processing large and complex medical imaging datasets remains an open challenge. To address this issue, we developed Med-ImageTools, a new open-source software package to automate data curation and processing while allowing researchers to share their data processing configurations more easily, lowering the barrier for other researchers to reproduce published works.

The AutoPipeline feature will improve the accessibility of raw clinical datasets on public archives, such as TCIA, allowing machine learning researchers to process analysis-ready formats without requiring deep domain knowledge. Another exciting potential of Med-ImageTools lies in building automated workflows using AutoPipeline. For a researcher to build an end-to-end automated pipeline starting from clinical DICOM datasets to outputting an inference-ready deep learning model, they could easily develop a reproducible processing step by configuring only the command line interaction of Med-ImageTools, making debugging and custom configurations simpler since the developer would not have to rely on a static script.

While our package aims to address challenges encountered across a few medical imaging labs, we acknowledge that there may be infinite other issues that may arise in DICOM datasets. This is one of the key reasons why our package is open-source for community involvement and contribution. Also, as stated previously, there are certain onerous tasks that cannot be automated and must undergo human supervision. These aspects of researcher-clinician collaboration are an inevitable part of medical imaging research and are subject to delay.

No single solution can completely solve the reproducibility crisis of medical deep learning research, due to a variety of issues ranging from ambiguous data processing techniques to stochasticity of model training. However, community-centered open-source solutions and increased clinical adherence to data standards, such as contour nomenclature Mayo 2018, can incrementally improve research quality and reproducibility, and make medical deep learning research more accessible for everyone.

2.3.6Reproducible environments

Alongside the package itself, this thesis's projects standardized on pixi for environment management: language-agnostic, cross-platform dependency solving with a self-documenting lock file, task automation, and multi-environment features. The iENE inference repository (Chapter 4) and the Dosarex repository (Chapter 5) both ship pixi environments, making it possible to reproduce the study’s full results with a single command.

2.3.7Availability, licensing, and live project status

Data availability

The Pancreatic-CT-CBCT-SEG dataset is available on The Cancer Imaging Archive at: https://doi.org/10.7937/TCIA.ESHQ-4D90. The pre-crawled Med-ImageTools database of the Pancreatic-CT-CBCT-SEG dataset is available on GitHub at: https://github.com/bhklab/med-imagetools/raw/tcia-crawls/csvs/imgtools_Pancreatic-CT-CBCT-SEG.csv.

The liver dataset was collected as part of the study titled Radiomics artificial intelligence modelling for prediction of local control for colorectal liver metastases treated with radiotherapy with Institutional Review Board and informed consent. Interested individuals should contact the senior author for access to the dataset, which will be made available following standard institutional rules for IRB and HIPAA.

The RADCURE dataset is publicly available on TCIA Welch 2024. Data published on TCIA are subject to TCIA data usage policies and restrictions.

Software availability

Source code available from: github.com/bhklab/med-imagetools also available on the PyPI software repository: pypi.org/project/med-imagetools.

Scripts for this study’s use cases are available from: github.com/bhklab/med-imagetools/tree/F1000Research

Archived source code at time of publication: https://doi.org/10.5281/zenodo.14766792

Live project status

Table 2.3Med-ImageTools live project metrics retrieved 19 Aug 2026.
Metric Value
Current release v2.15.0 (30 Apr 2026)
Commits 752
GitHub stars / forks / watchers 60 / 11 / 3
Open issues 32
PyPI downloads 665 last month
Distribution PyPI, Docker Hub, uvx
License MIT
CI/CD GitHub Actions, Codecov, ReadTheDocs, semantic versioning

2.4Chapter discussion

RADCURE provides 3,346 planning CTs with target and organ-at-risk contours, clinical variables and outcomes, roughly 3.5 times the patient imaging data of other head and neck datasets on TCIA (Ch.2.2). Med-ImageTools converts such DICOM collections into analysis-ready volumes through a single configurable command (Ch.2.3). RADCURE was curated largely with Med-ImageTools, and the RADCURE extraction was in turn the largest dataset on which Med-ImageTools was benchmarked. The benchmarks support the hypothesis that scripted curation is faster and more transparent than manual curation (Ch.2.3.4). Built-in parallelization ensures that researchers have access to their processed data much faster than they have in the past through manual curation or single-plexed processing scripts. More importantly, a larger gain is found in dataset-specific scripts of more than 1,000 lines that were replaced by one command whose parameters can be stored, reported, and rerun.

Preprocessing is a scientific choice, not a chore and this chapter's contributions to the literature and this thesis’ subsequent chapters demonstrate how one engine serves four evaluation studies and two clinical pipelines (Table 2.1). With the data and its processing fixed and open to inspection, the next chapter examines what models learn from them.

Chapter 3Evaluation26 min read · 11 figures · 6 tables

What are imaging models actually learning? Benchmarking, negative controls, and clinical acceptability

HypothesisA substantial fraction of published imaging “signal” is attributable to tumour volume or context, and geometric performance metrics do not translate to clinical acceptability.

12prognostic models benchmarked in the RADCURE challenge
9negative controls that destroy image content but keep volume
22%of expert manual contours failed blinded peer review

3.1Chapter introduction

Before building a clinical model, we pose two questions to frame our understanding of the studies in this chapter.

Is the signal real, or is it size? Tumour volume is prognostic, cheap, and already clinically legible. An imaging model that silently re-derives volume adds cost without information. Chapters 3.2 to 3.4 measure how much published imaging "signal" is volume in disguise—first observationally, by correlating challenge submissions' predictions with volume, then causally, by destroying image content while preserving volume and watching whether performance notices.

Does a good metric mean a usable model? Geometric segmentation metrics are the field's currency, but the clinical question is whether an expert would accept the contour. Chapter 3.5 measures the gap between the two for organs at risk; if geometric accuracy does not guarantee acceptability even for well-defined OARs, a lymph node contour cannot be assumed reliable, which motivates the most consequential design decision in Chapter 4: removing the dependency on lymph node segmentation.

3.2Multi-institutional prognostic modeling in head and neck cancer: evaluating impact and generalizability of deep learning and radiomicsCondensed

Kazmierski M*, Welch M*, Kim S*, McIntosh C, Rey-McIntyre K, Huang SH, Patel T, Tadic T, Milosevic M, Liu FF, Ryczkowski A. Cancer Research Communications;3(6):1140-51.

3.2.1Methods

The RADCURE prognostic modelling challenge (RADCURE-challenge) was organized by the Radiomics for Radiotherapy Research initiative at UHN, open to participants within UHN, with a predefined public protocol on GitHub. The challenge opened 14 Apr 2020 and final submissions were due 25 Jul. In total 12 models were evaluated and the winners were announced 31 Jul 2020.

Cohort: Princess Margaret Cancer Centre patients (n=2,552 from 2005–2017, definitive RT or chemoRT, ≥2 years follow-up or death, M0, and no prior surgery). Split by date of diagnosis to simulate a pseudo-prospective trial: 1,802 train / 750 test with participants blinded to test outcomes.

Endpoints and metrics: The primary endpoint is binary 2-year overall survival. The secondary endpoint is lifetime risk and survival curves in 1-month intervals to 23 months. AUROC was the primary metric, with AP as tiebreaker and C-index is used to compare risk predictions.

Organizer baseline models: baseline-clinical (age, sex, T/N stage, HPV); baseline-volume (primary tumour volume alone); baseline-radiomics (1,316 PyRadiomics v2.2.0 features, mRMR selection, grid-searched L2 logistic regression, 5-fold CV) van Griethuysen 2017Ding 2005.

3.2.2Results

Table 3.1Summary of challenge submissions and performance metrics. All models achieved performance better than random (FDR < 5%)
Rank Description AUROC AP C-index
1 Deep multitask logistic regression using EMR features and tumour volume. 0.823 [0.777–0.866] 0.505 [0.420–0.602] 0.801 [0.757–0.842]
2 Fuzzy logistic regression (binary) and Cox proportional hazards model (risk prediction) using EMR features and tumour volume. 0.816 [0.767–0.860] 0.502 [0.418–0.598] 0.746 [0.700–0.788]
3 Fuzzy logistic regression (binary) or Cox proportional hazards model (risk prediction) using EMR features and engineered radiomic features. 0.808 [0.758–0.856] 0.490 [0.406–0.583] 0.748 [0.703–0.792]
4 Multitask logistic regression using EMR features. 0.798 [0.748–0.845] 0.429 [0.356–0.530] 0.785 [0.740–0.827]
5 3D convnet using cropped image patch around the tumour with EMR features concatenated before binary classification layer. 0.786 [0.734–0.837] 0.420 [0.347–0.525] 0.774 [0.725–0.819]
6 2D convnet using largest GTV image and contour slices with EMR features concatenated after additional nonlinear encoding before binary classification layer. 0.783 [0.730–0.834] 0.438 [0.360–0.540] 0.773 [0.724–0.820]
7 3D DenseNet using cropped image patch around the tumour with EMR features concatenated before multitask prediction layer. 0.780 [0.733–0.824] 0.353 [0.290–0.440] 0.781 [0.740–0.819]
8 Multilayer perceptron (MLP) with SELU activation and binary output layer using EMR features. 0.779 [0.721–0.832] 0.415 [0.343–0.519] 0.768 [0.714–0.817]
9 Two-stream 3D DenseNet with multitask prediction layer using cropped patch around the tumour and additional downsampled context patch. 0.766 [0.718–0.811] 0.311 [0.260–0.391] 0.748 [0.703–0.790]
10 2D convnet using largest GTV image and contour slices and binary output layer. 0.735 [0.677–0.792] 0.357 [0.289–0.455] 0.722 [0.667–0.774]
11 3D convnet using cropped image patch around the tumour and binary output layer. 0.717 [0.661–0.770] 0.268 [0.225–0.339] 0.706 [0.653–0.756]
12 Fuzzy logistic regression (binary) and Cox proportional hazards model (risk prediction) using engineered radiomic features. 0.716 [0.655–0.772] 0.341 [0.272–0.433] 0.695 [0.638–0.749]

The winner was a deep multi-task logistic regression (MTLR) on EMR features plus tumour volume, which outperformed every other model on AUROC at FDR < 5% except the runner-up. Ablation analyses of the winning model localize its signal: EMR-only drops AUROC to 0.798, replacing the volume input with a 3D convnet image representation drops it to 0.766. One combined model using engineered features (number 3) performed worse than the exact same model using EMR features and volume only (number 2), indicating that the added complexity of radiomic features reduces performance. Risk stratification at a predicted 2-year event probability of 0.5 gave hazard ratios of 8.64 (best combined), 5.96 (best EMR-only) and 4.50 (best radiomics), all p<10⁻¹⁸.

Figure 3.1Model results. A) Overview of model characteristics. The characteristics are grouped into input data, prediction head (i.e., how were the survival predictions made) and model type (whether the model involved any nonlinearities and/or convolutions). PH: proportional hazards, MLP: multilayer perceptron, *: age, sex, stage, HPV status. B–D) Performance of all models, including benchmark models, in terms of 2-year AUROC, 2-year average precision and C-index of the lifetime risk, respectively. The results are ranked by AUROC (numbers above bars indicate the overall rank of each model). Error bars represent 95% confidence intervals computed using 10,000 stratified bootstrap replicates. Dashed gray lines indicate random guessing performance (0.5 for AUROC and C-index, 0.14 for AP). E–G) show the Kaplan–Meier survival estimates in low- and high-risk groups identified by the best performing model in each category (combined, EMR only and radiomics), respectively. Test set patients were stratified into two groups based on the predicted 2-year event probability at 0.5 threshold. In each case, there were significant differences in survival between the predicted risk groups (HR, 8.64, 5.96, and 4.50, respectively, p<10−18 for all).

3.2.3Volume confounding

Table 3.2Spearman correlations between model predictions and tumour volume.
Model class ρ Our interpretation
baseline-radiomics 0.85 predictions driven primarily by volume
Engineered-radiomics submission (#12) 0.79 same, worse
Two of three convnets > 0.5 moderate-to-strong
Best imaging-only model (#9) 0.22 weak — with AUROC 0.766, better than volume alone
Top combined models (#1, #2) < 0.5 use volume as an input yet exploit EMR beyond it
Figure 3.2Volume dependence of predictions. Spearman rank correlation of the predictions of each model with tumour volume against performance in terms of AUROC (A) and C-index (B), respectively.

The top models fall into an optimal region of low (but nonzero) volume correlation and high performance. Note that while models 1 and 2 used tumour volume as one of the input variables, their predictions moderately correlate with volume (0.4 < ρ < 0.6), indicating they can exploit additional information present in the EMR features. Higher correlation leads to decreased performance as the predictions are increasingly driven by volume only. Most radiomics-only models fall in the moderate-to-strong correlation region (ρ ≥ 0.5), although deep learning predictions correlate at notably lower level than engineered features. Interestingly, the best radiomics submission (number 9) achieves the lowest volume correlation, suggesting that it might be possible to learn volume-independent image-based predictors.

3.2.4External validation

The top three models plus the best deep learning submission were evaluated across three external datasets: HN1 (n=137) Wee 2019, MDACC (n=627) Grossberg 2018, and GPCC HN (n=298), an external private dataset. The three datasets are significantly heterogeneous in disease site, HPV status and outcome prevalence.

The top model (number 1) was the best performing model in two datasets, with an AUROC of 0.852 in HN1 and 0.742 in MDACC. In GPCC HN, it was slightly exceeded by model number 2 (AUROC 0.662 vs 0.686), but the confidence intervals overlapped between all models within each cohort. Performance dropped in two of three datasets but remained better than random (p < 0.0001).

Figure 3.3External validation performance of the top three submissions and the best deep learning submission (number 5): AUROC (A) and C-index (B). The red line indicates the performance achieved by the winning submission in the challenge test set. The performance of tumour volume alone is shown for comparison.

3.2.5Discussion

ML combined with simple prognostic factors outperformed multiple advanced CT radiomics and deep learning methods. Although deep learning–based imaging models generally outperformed approaches based on handcrafted features, none proved superior to the combined EMR-volume model, even when combined with EMR data. The paper’s conclusions match those of Ger and colleagues, who did not find significant improvement in prognostic performance of handcrafted CT and PET imaging features in HNC compared with volume alone and of Vallières and colleagues, whose best performing model for overall survival also combined EMR features and volume Ger 2019Vallières 2017.

3.3Deep-CR-MTLR: a Multi-Modal Approach for Cancer Survival Prediction with Competing Risks

Kim S*, Kazmierski M*, Haibe-Kains B. Proceedings of the AAAI Spring Symposium on Survival Prediction. PMLR 2021;146:223–231.

3.3.1Introduction

The RADCURE-challenge evaluated twelve models against a single binary endpoint, two-year overall survival, which pools death from cancer with death from other causes, making clinical decisions hard to derive, since those decisions trade cancer control against treatment-related harm. Deep-CR-MTLR was designed to extend MTLR from a single-event setting to competing risks, by fitting a separate set of interval parameters for each mutually exclusive event and normalizing over both time and event, so that the model predicts a cause-specific cumulative incidence function rather than an all-cause survival curve Yu 2011Kim 2021. The resulting objective is similar to DeepHit, but based on MTLR’s unique discretized time bin function rather than a discrete-time likelihood Lee 2018. The model also carries an image arm that the top challenge submission did not, a 3D convolutional network over a 50 × 50 × 50 voxel patch centered on the primary tumour, pooled to 512 dimensions and concatenated with the clinical vector before a shared MTLR head. If CT holds tumour-specific prognostic signal, the image arm should add more to the prediction of cancer death than to the prediction of death from other causes, and a pooled endpoint would hide that difference Kim 2021.

3.3.2Methods

Competing-risks formulation. For each patient we observe a time to event or censoring, an event indicator e that is 0 for censoring and otherwise runs from 1 to E, and a feature vector x. Here E = 2: death from the primary cancer and death from other causes, the latter including comorbidity and second cancers. Each patient experiences at most one of the two. The quantity of interest is the cumulative incidence function (CIF), the probability that event e has occurred by a given time. Fitting a single-event model to each cause in turn, with the other cause treated as censoring, gives biased probabilities unless the risks are independent, which is generally not the case Kalbfleisch 2002.

MTLR divides the time axis into K intervals, the last of them open-ended, and fits one logistic regressor per interval boundary. The regressors are tied together so that predictions stay consistent over time: a patient predicted to have died cannot be alive at a later boundary Yu 2011. Deep-CR-MTLR gives each event e its own weights θe,k and bias be,k at each boundary k, and scores the outcome “event e in interval i” by summing over the boundaries from i onward, with a score of zero for the final interval. Because the events are mutually exclusive, the scores are normalized over all events and intervals together, which gives the probability that event e occurs in interval i:

$p_{e,i}(x) = \frac{exp\ \left( s_{e,i}(x) \right)}{\Sigma_{i' = 1}^{K}\Sigma_{e' = 1}^{E}exp\ \left( s_{e',i'}(x) \right)}$ (3.1)

Training minimizes the negative log-likelihood with an L2 penalty on the MTLR weights. A patient with an observed event contributes the probability of that event in that interval. A censored patient could still experience either event, and so contributes the summed probability of both events over every interval from the censoring interval onward.

Multimodal architecture. Deep-CR-MTLR follows the Neural MTLR approach, in which a neural network replaces the linear predictor beneath the MTLR layer Fotso 2018. The clinical input is a vector of 24 values built from age at diagnosis, sex, disease site and stage, ECOG performance status, HPV status, radiation dose and use of chemotherapy, with categorical variables one-hot encoded and continuous variables normalized. The image arm is a 3D convolutional network applied to the 50 × 50 × 50 voxel patch around the primary tumour: a 50mm cube at 1mm isotropic spacing, centered on the centroid of the primary GTV, with intensities clipped to −500 to 1,000 HU. The network has two convolutional blocks. Each block is two convolutions, each followed by batch normalization and ReLU activation, and then 2 × 2 × 2 max pooling with stride 2. The first convolution uses a 5 × 5 × 5 kernel and the rest 3 × 3 × 3, and the channel count rises through 64, 128 and 256 to 512. Global average pooling reduces each channel to a single value, giving a 512-dimensional image representation. This is concatenated with the clinical vector into a 536-dimensional vector and passed through three fully connected hidden layers with ReLU activations, shared between the two modalities. The output of the shared layers takes the place of x in equation 3.1, and the MTLR layer returns the probabilities of equation 3.1.

The convolutional network, the shared layers and the MTLR weights are trained jointly by gradient descent, so the image representation is learned against the competing-risks likelihood itself. The architecture was selected after testing several depths and kernel sizes on the training and fine-tuning data, and was kept small on purpose to limit overfitting on a cohort of this size. The convolutional network, the shared layers and the MTLR weights are trained jointly by gradient descent, so the image representation is learned against the competing-risks likelihood itself. The architecture was selected after testing several depths and kernel sizes on the training and fine-tuning data, and was kept small on purpose to limit overfitting on a cohort of this size.

Cohort and outcomes. The study used the RADCURE-challenge cohort and its split by date of diagnosis (n = 2,552; 1,802 for training and fine-tuning, 750 for testing), so every test patient was diagnosed after the most recently diagnosed training patient. Each patient had a pre-treatment planning CT with the primary tumour contoured by a radiation oncologist, and all were followed for at least two years or until death. Because the test set holds the most recent diagnoses, its follow-up is shorter and it has fewer events (Table 3.3): 102 cancer deaths and 39 deaths from other causes.

Table 3.3Event distribution in the Deep-CR-MTLR training/fine-tuning and test sets.
Outcome Training/fine-tuning (n = 1,802) Test (n = 750)
Alive or censored 1,065 (59%) 609 (81%)
Death from cancer 342 (19%) 102 (14%)
Death from other causes 395 (22%) 39 (5%)

Training. The model was implemented in PyTorch with PyTorch Lightning and trained with the Adam optimizer at a learning rate of 10−4 Paszke 2019Falcon 2019Kingma 2015. Training patches were augmented with random in-plane rotation, random flips and additive Gaussian noise. The number of hidden layers in the shared network and the regularization constant was chosen on the fine-tuning set. The network weights and the MTLR weights were regularized separately, because the MTLR weights needed a stronger penalty to keep predictions smooth across time intervals. The time axis was discretized at quantiles of the observed event times, with the number of interval boundaries set by the square root of the number of training patients with an observed event. The MTLR layer has 58 outputs, 29 for each event.

Comparators and metrics. To separate what each modality adds, the multimodal model was compared with three single-modality models: the shared network on clinical variables alone (neural MTLR), the convolutional network on images alone, and a linear MTLR on clinical variables. Two cause-specific metrics were reported for each event. The two-year AUROC, computed between the predicted CIF at two years and the indicator of that event within two years, measures how well a model picks out patients at high short-term risk. The concordance index (C-index) Harrell 1996, computed on a lifetime risk score that aggregates the predictions over all intervals, measures how well it ranks patients over the whole follow-up.

3.3.3Results

Deep-CR-MTLR reached two-year AUROC 0.774 and C-index 0.788 for cancer-specific death, and 0.781 and 0.761 for other-cause death, the highest value on all four measures (Table 3.4). The same network on clinical variables alone reached 0.768 and 0.756 for cancer-specific death, whereas the convolutional network alone reached 0.742 and 0.746 Kim 2021. The neural MTLR on clinical variables beat the linear MTLR on every measure, which points to non-linear interactions among clinical variables as one source of the gain.

Table 3.4Test-set performance of Deep-CR-MTLR and single-modality comparators. Cause-specific two-year AUROC and C-index for death from cancer and death from other causes (n = 750). The highest value in each column is in bold.
Model AUROC C-index
Cancer Other Cancer Other
Linear MTLR (clinical) 0.740 0.724 0.747 0.679
Convnet (images) 0.742 0.740 0.746 0.707
Neural MTLR (clinical) 0.768 0.755 0.756 0.726
Deep-CR-MTLR (clinical + images) 0.774 0.781 0.788 0.761

3.3.4Discussion

Extending MTLR to competing risks changed the estimator but maintained the same conclusion of the RADCURE-challenge. The addition of imaging to clinical variables yielded a modest improvement in the prediction of cancer-specific death, with two-year AUROC increasing from 0.768 to 0.774 and the C-index from 0.756 to 0.788. The improvement in the model’s predictions for both death from cancer and from other causes (C-index 0.726 to 0.761) indicates that the signal likely does not reflect tumour biology alone.

The main limitation of the study is that its reported differences are point estimates from a single institution without external validation. Therefore, these results should be interpreted as descriptive and are more so a demonstration of how Deep-CR-MTLR allows future studies to investigate competing risks.

The results of the RADCURE-challenge and Deep-CR-MTLR suggest that the limit lies in the information contained in the features, not in the estimator fitted to them. This next study tests this hypothesis directly, by destroying image content and measuring whether performance changes.

3.4Collaborative study: negative controls for volume confounding (READII-2-ROQC)

Adapted from: Scott KL, Kim S, Siraj J, et al. Scott 2026

Role of the candidate: Second author. Contributed to the conception and design of the experiment and software framework, curated and processed the imaging data with Med-ImageTools, and contributed to the interpretation of results and the direction of subsequent analyses.

3.4.1Motivation

READII-2-ROQC generalizes Welch and colleagues’ experiment into a reproducible framework. Welch and colleagues shuffled image intensity values by randomly permuting voxels across the entire 3D dataset and refitting the Aerts signature (MW2018) on both original and randomized images yielded similar C-indices on both, demonstrating that the signature was a surrogate for tumour volume Welch 2019. READII-2-ROQC (Radiomic Extraction and Analysis for DICOM Images to Refine Objective Quality Control) makes this experiment configurable with nine controls rather than one, and extends it from engineered features to an imaging foundation model. If a feature is merely a proxy for volume, its biological interpretability and utility in explainable AI frameworks are fundamentally compromised Scott 2026.

3.4.2Methods

Figure 3.4Overview of the READII-2-ROQC pipeline. Data inputs comprise DICOM images, segmentation masks, and associated clinical data. Med-ImageTools pre-processing applies quality checks, interlaces images based on metadata, converts 2D DICOM slices to 3D NIfTI volumes, and organizes files by sample. Negative control generation is customized by region, permutation, and crop methods. Feature extraction can produce shape, intensity-based, textural, and higher-order or deep features. Downstream analysis can investigate feature correlations, prediction modelling, etc. For data sharing and reproducibility, a RadiomicSet is constructed from patient metadata, extracted features, and pipeline settings.

Stage 1: Curation. Med-ImageTools converts DICOM and segmentation to NIfTI, extracts header metadata to ensure spatial registration, generates a unique sample identifier per image–mask pair for provenance, programmatically separates multiple ROIs, and emits a metadata index.

Figure 3.5Negative control permutation and region combinations on a sample from NSCLC-Radiomics (LUNG1). a. Slice of an original lung CT with the segmented tumour mask overlaid in green. b-j) Cube crop of the slice in a with the following negative control combinations: b) Full-Random; c) Full-Sample; d) Full-Shuffle; e) ROI-Random; f) ROI-Sample; g) ROI-Shuffle; h) Background-Random; i) Background-Sample; j) Background-Shuffle.

Interactive · Figure 3.5 and Ch. 3.4.3

Nine ways to destroy an image

Three permutations crossed with three regions. Pick a control to see what it does to the voxels and how each model responded.

RandomSampleShuffle Full ROI Background

Full × Shuffle

  • Aerts survival signature
  • Choi HPV signature
  • FMCIB foundation model

Letters match the panels of Figure 3.5. Image geometry is kept, so the tumour mask and its volume never change.

Stage 2: Negative-control generation. Three permutation classes crossed with three spatial regions give nine controls:

  • Permutations: Random (voxel intensities drawn from a discrete uniform distribution over the region's original range); Sample (resampling with replacement from the original distribution, preserving intensity frequencies); Shuffle (reordering existing voxels with the exact histogram preserved, all spatial texture destroyed).

  • Regions: Full image, ROI (tumour), Background (everything else).

Geometry (direction, origin, spacing) is copied from the original to maintain mask registration, and cropping/resizing occur after control generation, so the available voxel distribution is not altered. The Full × Shuffle-permutation configuration replicates Welch’s 2019 study.

Stage 3: Feature extraction.

PyRadiomics 3.0.1a: all default features plus Compactness1 (to reproduce Aerts), across original, wavelet, square, square-root, logarithm, exponential and gradient filters — 1,317 features per image; bin width and gray-level discretization 25; resampling to 1 × 1 × 1mm³ van Griethuysen 2017.

FMCIB (Foundation Model for Cancer Imaging Biomarkers) Pai 2024: 4,096 features from public pretrained weights, with images cropped to 50 × 50 × 50 voxels around the tumour centroid without masking the ROI.

Stage 4: Packaging. A Snakemake pipeline emits a RadiomicSet MultiAssayExperiment R object per dataset, published on ORCESTRA with a per-dataset Zenodo DOI and an auto-generated "Data Nutrition Label" recording pipeline version, metadata and provenance.

Datasets: LUNG1 421 Aerts 2014 + HN1 137 Wee 2019 + RADCURE 2,994 Welch 2024 = 3,552 tumour volumes. The RADCURE train/test split is read directly from the RADCURE-challenge column of the released clinical spreadsheet Kazmierski 2023.

Radiomic signatures evaluated: the Aerts overall survival signature (fixed coefficients, not refit) Aerts 2014, and the Choi HPV status signature (refit as logistic regression on RADCURE OPC training data, tested on the RADCURE test split, externally validated on HN1) Choi 2020, and volume-only baselines using Mesh Volume alone. Metrics: Harrell's C-index and AUROC with 1,000 stratified bootstrap resamples. We hypothesize that if a signature captures information beyond volume, the negative control would yield much lower performance.

3.4.3Results

Figure 3.6Violin plots for evaluation of radiomic signatures with READII-2-ROQC negative control images. Predictions and 95% CIs were generated with 1000-times stratified bootstrapping for each image type. Black dashed line at 0.50 (random). Red dash-dot line shows prediction result for the Mesh Volume feature for each dataset. a-c) Overall survival prediction C-index results with the Aerts survival signature applied to the RADCURE (a), HN1 (b) and LUNG1 (c) datasets.

The Aerts survival signature does not notice the destruction of the image. Across all three datasets the result is a flat line: in RADCURE the original signature yields 0.67 C-index and all nine negative controls are within ±0.02 of it, with the volume-only reference running through the middle of the whole set. HN1 behaves identically at 0.63–0.65 with wider distributions (n=137) and LUNG1 has narrow distributions at 0.60–0.62. No control is distinguishable from the original, and none from volume alone.

Figure 3.7Violin plots for evaluation of radiomic signatures with READII-2-ROQC negative control images. Predictions and 95% CIs were generated with 1000-times stratified bootstrapping for each image type. Black dashed line at 0.50 (random). Red dash-dot line shows prediction result for the Mesh Volume feature for each dataset. d-f) HPV status prediction area under the receiver operating characteristics curve (AUROC) results with the Choi HPV status signature used in a logistic regression model. The model was trained with OPC patients from the RADCURE training set (d), tested with the RADCURE test set (e), and externally validated with the HN1 dataset (f).

The Choi HPV status signature carries real image signal outside the tumour. The signature demonstrated improved performance over the volume-only model when applied to original images while perturbations applied to the Full and Background regions resulted in substantial performance degradation, whereas perturbations confined to the ROI had a comparatively smaller effect. This pattern suggests that the predictive signal for HPV status does not come from features within the tumour but rather its peripheries and outside.

Figure 3.8Clustered feature analysis. a. 2D slice of a bounding box cropped Original lung tumour image input to PyRadiomics. b. Clustered Pearson correlations for PyRadiomics features averaged across all GTVs. c. Lung tumour slice (a) with the Sample perturbation applied (left to right) to the ROI, Background, and Full regions. d. Clustered absolute differences in PyRadiomics feature Pearson correlation values between Original and Sample negative control images, averaged across all GTVs. e. 2D slice of a cube cropped Original lung tumour, resized to 50x50 for input to FMCIB. f. Clustered Pearson correlation values between extracted FMCIB features, averaged across all GTVs. g. Lung tumour slice (e) with the Sample perturbation applied (left to right) to the ROI, Background, and Full regions. h. Clustered absolute differences in FMCIB feature Pearson correlation values between Original and Sample negative control images, averaged across all GTVs. i. Kernel density estimate plot of PyRadiomic feature correlation distributions from the Original, Full-Sample, ROI-Sample, and Background-Sample images. j Kernel density estimate plot of FMCIB feature correlation distributions from the Original, Full-Sample, ROI-Sample, and Background-Sample images.

FMCIB reads the background. For the foundation model, ROI-based negative controls produced negligible differences in correlation structure relative to the original images (Figure 3.8h,j). However, when perturbations were introduced to the background, the correlations diminished, regardless of whether the ROI was perturbed (Figure 3.8h,j). These features are insensitive to perturbations within the tumour volume and are instead primarily derived from information at the tumour boundary or from surrounding background regions.

Figure 3.9Correlation analysis results. a) Heatmap of absolute Pearson correlations averaged across all GTVs for four PyRadiomics texture features and all shape class features extracted from the ROI-Shuffle negative control images. b-e) GLCM Cluster Prominence (b), GLDM Dependence Variance (c), NGTDM Busyness (d), and GLRLM Gray Level Non-Uniformity (e) as a function of volume for the Original (purple), ROI-Random (blue), ROI-Sample (red), and ROI-Shuffle (green) negative control images.

Investigating four representative texture features as archetypes and their correlations with tumour volume. Features with stronger volume dependence exhibited consistent relationships with tumour volume across all negative control configurations, with minimal deviation between original and permuted images, as seen with GLRLM Gray Level Non-Uniformity (Figure 3.9e), one of the features included in the Aerts signature Aerts 2014. There are features with weaker volume correlation, like GLCM Cluster Prominence (Figure 3.9b) that remained largely unchanged under spatial perturbation, suggesting limited biological or structural relevance despite apparent independence from volume. Finally, features sensitive to negative control perturbations while maintaining lower correlation with volume, such as GLDM Dependence Variance (Figure 3.9c) represent candidates with potential biological interpretability. Supplementary Table 2 ranks the 20 features most changed by each negative control, and Supplementary Table 3 the ten most changed across all nine. Both are dominated by GLSZM and GLCM texture features computed on filtered images, led by wavelet-HHH GLSZM Small Area High Gray Level Emphasis (first or second under every control).

3.4.4Discussion

Predictive performance alone constitutes insufficient evidence of biological validity. Features that remain invariant under spatial perturbation while correlating with tumour volume may not capture intrinsic tumour heterogeneity, irrespective of their discriminative accuracy. Consequently, published radiomic signatures warrant re-evaluation against volume-only baselines rather than acceptance based on discrimination metrics alone. The demonstrated inadequacy of correlation filtering indicates that volume confounding cannot be resolved through post-hoc feature selection and must instead be interrogated directly.

The differential sensitivity of the Choi HPV status signature to full-image and background perturbations, relative to ROI-restricted perturbations, localizes predictive signal to the tumour boundary rather than the intratumoural region, supporting the deliberate modelling of peritumoural context rather than its exclusion. These findings align with emerging evidence supporting the relevance of tumour-stroma interactions Fan 2023 and peritumoural radiomics Sun 2018Zhang 2025 for biologically meaningful prediction tasks. Future works of READII-2-ROQC can compare its additional region types that are already implemented to investigate the peritumoural region including: contraction, contraction ring, expansion, expansion ring, and bi-directional ring.

3.5Collaborative study: clinical acceptability of auto-segmentation (SCARF)

Adapted from: Marsilla J, Welch ML, Siraj J, et al. Marsilla 2026.

Role of the candidate: co-author and member of the core development team since 2019. Contributed to conceptualization, data curation, software development and methodology, and to review and editing of the manuscript. The clinical acceptability study was added after the candidate's primary involvement. Med-ImageTools was noted to have contributed 240 of 450 developer-hours saved.

3.5.1Methods

Figure 3.10The SCARF Framework. The auto-Segmentation Clinical Acceptability and Reproducibility Framework evaluates auto-segmentation models in five steps: 1) Curate datasets 2) Identify and train models 3) Evaluate model performance using geometric metrics 4) Assess clinical acceptability 5) Test generalizability

Models. Twelve open-source architectures refactored into PyTorch Lightning under one shared loss (weighted TopK cross-entropy over the hardest 10% of voxels + Focal Tversky), with models excluded based on the following criteria: 2D-only designs not convertible to 3D without breaking architectural integrity, close similarity to an included architecture, unmaintained code, or non-integrability into Lightning. nnU-Net was included in the secondary stage of the study as a separate use case Isensee 2021.

Table 3.5External HNC imaging and segmentation datasets. All datasets are openly available for download and research purposes.
Dataset Institution # Use in Manuscript Available Data
Imaging Clinical OAR
RADCURE UHN 2552 Training/Tuning/Internal Testing ☑️ ☑️ ☑️
HNSCC-3DCT-RT MIAMI 94 Generalizability Assessment ☑️ ☑️ ☑️
Deepmind HMS + Multi-Site 35 Generalizability Assessment ☑️ ☑️
PDDCA HMS 48 Generalizability Assessment ☑️ ☑️
Radiomics-HN1 MAASTRO 137 Generalizability Assessment ☑️ ☑️ ☑️
STRUCTSEG19 CAS 50 Generalizability Assessment ☑️ ☑️
Head-Neck-CT-Atlas MDACC 215 Generalizability Assessment ☑️ ☑️ ☑️
SegRap 2023 UESTC 120 Generalizability Assessment ☑️ ☑️
HaN-Seg SLOVENIA 42 Generalizability Assessment ☑️ ☑️

Data. Med-ImageTools was used to curate radiotherapy head and neck cancer imaging datasets from 9 different institutions, totalling 3,293 patients. We used RADCURE for training: 582 patients with all 19 essential OARs, split 479/44/59. RADCURE contains 34 distinct OARs, which include all 19 essential structures for RT planning.

Metrics. Dice similarity coefficient (DSC) and 95th-percentile Hausdorff distance (95HD) are used to evaluate all models. The refined model is additionally investigated with surface distance, added path length, false-negative volume/length and Jaccard. Kruskal–Wallis H-tests between models per OAR. Dosimetric evaluation was intentionally excluded to prioritize anatomical accuracy over surrogate measures of dose/volume metric impact.

3.5.2Results: geometric performance

The top three models were all U-Net variants. WOLNET was selected as it was the only model ranking top-5 for every OAR and top-3 for 16 of 19. Refined WOLNET on the RADCURE held-out set: median DSC 0.82 (95% CI 0.67–0.97), 95HD 2.8mm (-12.0mm to 17.6mm) overall. Comparatively, nnU-Net yielded DSC 0.87 (0.75–0.97), 95HD 2.0mm (-7.7mm to 11.7mm), achieving higher DSC and lower 95HD on all OARs than refined WOLNET on RADCURE. On external datasets, nnU-Net demonstrated higher performance with some outliers, such as acoustic structures.

Figure 3.11Quantitative clinical acceptability results of refined WOLNET. Results of the acceptability test by representing mean Likert rating counts for each OAR in a heat-map for A) ground-truth contours (GT) and B) AI-generated contours (AI). The higher the value of a box the more contours of that given OAR (row) had any given Likert rating (column) and the lighter the corresponding box appears.

3.5.3Results: clinical acceptability

From Ch. 3.5.3 – 3.5.4

Geometry and experts disagree

Each line joins a structure’s Dice score to the mean acceptability its AI contour received from four blinded radiation oncologists. The lines cross.

Dice (DSC) Acceptability (1–5) 00.51 15 3.5 cut-off Larynx 0.88 Optic chiasm 0.38 2.38 2.90
78%of expert ground-truth contours rated acceptable (mean rating above 3.5)
52%of AI contours rated acceptable
2.90 vs 3.03Optic chiasm: worst Dice of any structure, yet AI and ground truth were statistically indistinguishable

We evaluated contours generated by refined WOLNET vs manual contours used as ground-truth to train WOLNET. Four expert observers (head-and-neck fellows or staff radiation oncologists with >10 years' experience) were blinded to contour source and reviewed contours in a re-engineered QUANNOTATE web interface with bone/soft-tissue/lung windowing presets, by OAR category rather than by patient on a 5-point Likert scale Kim 2023.

Mean acceptability rating (MAR) of the ground truth scored 3.8 ± 0.9 versus the AI contours’ 3.4 ± 1.0. With a threshold of MAR>3.5 as clinical acceptability, 78% of ground-truth contours were acceptable versus 52% of AI contours. 16 of 19 AI OARs were determined to be clinically acceptable with minor edits. OARs that did not pass the test after revision were larynx (2.38), brainstem (2.80), and chiasm (2.90).

3.5.4Discussion / Findings

22% of expert manual contours failed the acceptability threshold with ground-truth MAR only 3.8±0.9, and 15 manually delineated OARs on average were considered clinically acceptable, compared to 9 OARs generated by deep learning. This is consistent with Brouwer and colleagues' study that delineated 9 swallowing OARs in 29 patients under five published guidelines and found median concordance with the reference guideline of 0.54 for the pharyngeal constrictors, 0.56 for laryngeal structures and 0.07 for the cricopharyngeal and oesophageal inlet muscles. The resulting variance in mean dose reached 3.5±3.2 Gy and changed the modelled NTCP for dysphagia by more than 10 percentage points in 7% of patients Brouwer 2014. Van Dijk and colleagues observed comparable instability under blinded review. In a Turing-test evaluation across 22 head and neck OARs, raters preferred manual contours overall, and the margin over deep learning was narrower van Dijk 2020.

Geometric rank and clinical acceptability ranks diverge. The optic chiasm had the worst DSC (0.38) and worst 95HD (9.6mm) of any structure, yet its AI acceptability was statistically indistinguishable from its own ground truth (2.90 vs 3.03). The larynx was the least acceptable AI structure (2.38) despite a respectable DSC of 0.88 on RADCURE. Our results build on a common pitfall noted by the Metrics Reloaded consensus that smaller structures tend to receive lower DSC scores even with small deviations, complicating cross-OAR comparisons with the effect being larger for DSC than 95HD Reinke 2024. Given that clinical acceptability testing was performed by only four radiation oncologists, statistical power of our conclusions is limited. Future studies can invite broader clinician participation for a robust conclusion.

3.6Chapter discussion

Let’s reconsider the two questions at the start of the chapter.

Is the signal real, or is it size? Prognostic performance in the challenge was driven by EMR features and volume, with engineered radiomics correlating with volume at ρ=0.79–0.85. In Deep-CR-MTLR, the image arm added as much to the prediction of other-cause death as to cancer death, and its gain was never tested against volume. A published radiomic survival signature survived the destruction of image content across all nine negative controls, an HPV-status signature drew its signal from the tumour periphery, and a foundation model’s features derived from the background rather than the tumour.

Does a good metric mean a usable model? SCARF demonstrated that good geometric performance does not guarantee clinical acceptability and the experts' own contours fail peer review 22% of the time.

However, volume-independent imaging signal is learnable and must be demonstrated rather than assumed. The RADCURE-challenge model 9 achieved ρ=0.22 with AUROC 0.766, and READII’s perturbation-sensitive, volume-independent feature archetype exists. To increase the chances of clinical adoption, a model must be well characterized through volume correlation analysis, external validation, negative-control or ablation evidence, expert-anchored evaluation, and an operating point tied to a clinical decision.

The next chapter presents a model built with these specifications. Each design decision is traceable to a finding from this chapter: the patient-level target and radiologist supervision, the absence of any node-segmentation dependency (Ch.3.5), the explicit volume-correlation analysis (Ch.3.2 and 3.4), external validation under case-mix shift (Ch.3.2.4), and characterizing the model’s operating thresholds to a specific clinical decision (Ch.1.3).

Chapter 4Decision-aligned model36 min read · 9 figures · 8 tables

Patient-level prediction of imaging extranodal extension from radiotherapy planning CT in oropharyngeal carcinoma using deep learning

HypothesisA patient-level model can exceed volume and clinical baselines and stratify outcomes comparably to a clinician.

0.913AUROC on the RADCURE held-out test set (n=163)
0.671AUROC on the external Maastro cohort (n=175)
0lymph node contours required at inference

Kim S, Huang SH, Bartlett E, Yu E, Hoebers F, Postma AA, Palm WM, McIntosh C, Bratman S, Waldron J, O'Sullivan B, Haibe-Kains B*, Hope A*

This work was presented orally at ICHNO 2024, where it received the Best Paper Award and is currently under review with the Journal of Clinical Oncology.

4.1Introduction

Extranodal extension (ENE), defined as the growth of metastatic disease in lymph nodes through lymph-nodal capsule into surrounding soft tissue, has been identified as a major negative prognostic factor for head and neck squamous cell carcinoma (HNSCC) and is associated with the risk of progression and distant metastasis Huang 2020. ENE was incorporated into the 8th edition of the UICC/AJCC staging criteria (TNM) for non-viral HNSCC and is now also included in the 9th edition TNM for HPV associated (HPV+) oropharyngeal carcinoma Huang 2025Brierley 2025Brierley 2026. While pathologic indication of ENE (pENE) is the gold-standard of determining ENE, pENE is not available in non-surgically treated patients, which accounts for the majority of HNSCC, nor is it available before the initial treatment decision has been made Schlichting 2019Zheng 2025.

Imaging ENE (iENE) has emerged as a novel prognostic factor independently associated with oncologic outcomes and a detailed radiologic criteria system has been developed and validated for radiology use Huang 2020Henson 2024. Huang and colleagues demonstrated that staging schemas incorporating imaging-based ENE (iENE) show significant improvements compared to TNM in discriminating high-risk and low-risk patients for overall survival, disease-free survival and distant control Huang 2020. This is especially consequential in oropharyngeal carcinoma, where treatment intensity is driven by the presence of iENE Ferris 2022.

Accurately labeling iENE requires substantial expert radiologist training. Sahin and colleagues have demonstrated that precise iENE determination is a difficult task, with high interobserver variability and low diagnostic accuracy without substantial training Sahin 2025. This motivates an automated approach to make consistent iENE determinations. Deep-learning screening systems have been shown to recapitulate radiologist-level expertise in chest radiography and computer-aided diagnostic settings Tavaziva 2022Yacoub 2022. Prior AI work on ENE has predicted pathologic ENE of individual lymph nodes rather than patient-level iENE Kann 2018Kann 2020Ye 2026. Dayan and colleagues recently reported an automated pipeline that segments involved lymph nodes on treatment-planning CT and classifies the iENE status of the largest node Dayan 2026. Similarly, our model is trained on radiation treatment-planning CT rather than diagnostic CT, allowing it to be deployed directly within the radiotherapy workflow on imaging routinely acquired for every patient.

We present a patient-level deep learning model that predicts radiology-defined iENE from treatment planning CT scans, trained directly on radiologist-determined iENE labels rather than pathologic ENE. The model is designed for operational deployment: it requires no manual lymph node segmentation, operating end-to-end through an automated larynx localization step that defines the input crop, and produces a single patient-level prediction interpretable on the same scale as the radiologist's clinical determination. We train and internally validate the model on the publicly accessible RADCURE cohort Welch 2024 and externally validate on an independent external cohort from Maastro Clinic. The full training and inference pipelines, trained model weights, and reproducible software environment are released as open-source resources to enable downstream validation and adoption.

4.2Methods

Datasets/Experimental Setup. We leverage three public head and neck cancer datasets with RT planning CT images to train all models in this study: “RADCURE”, “HNSCC”, and “HEAD-NECK-RADIOMICS-HN1” Welch 2024Grossberg 2018Wee 2019. The “HNSCC” and “HEAD-NECK-RADIOMICS-HN1” datasets used to train the nnU-Net larynx segmentation model were processed using Med-ImageTools Kim 2025, filtering ROI names found in each sample’s DICOM RTSTRUCT and saving the underlying image and larynx segmentation mask into NIfTI format. Med-ImageTools’ AutoPipeline feature handles all DICOM handling, processing logic, and image operations. RADCURE was excluded from the training set for the larynx segmentation model to remove any training biases of locating the larynx.

The RADCURE dataset is a large dataset of HNSCC patients between 2005-2017 and their images and contours collected clinically during RT planning. A subset of 915 patients with newly diagnosed primary OPC and radiologist-determined iENE labels was included in this study. The dataset was split as close to 80/20 based on diagnosis date to simulate a pseudo-prospective trial, resulting in a training set of 752 patients and a held-out set of 163 patients. An additional dataset from the Maastro clinic at Maastricht, Netherlands is used for external validation of the iENE model. The dataset is composed of 175 OPC patients and their treatment planning CT.

iENE Label Determination. iENE labels in RADCURE were retrospectively determined by a single experienced head and neck radiologist from the radiotherapy planning CT. The radiologist’s determinations were made prior to any formalization of criteria by consensus groups, but followed closely to the ASHNR criteria, considering iENE positive only when there were unequivocal imaging findings. iENE labels in the Maastro cohort were also assessed retrospectively by two neuroradiologists, using the modality with the highest diagnostic quality available at staging (Diagnostic MRI, Diagnostic CT, Planning PET-CT), based on previously established diagnostic criteria Hoebers 2022. Only the CT scan of the planning PET-CT was used to determine iENE.

Image Preprocessing. CT volumes were resampled to 1mm isotropic XY spacing. Intensity values were windowed to [-500, 1000] and normalized to [0, 1]. The predicted larynx mask from the nnU-Net was used to compute a centroid, which defined the center of a 256 × 256 × 128 voxel crop fed to the iENE model. No additional contrast or artifact correction was applied.

Baseline Comparison Models. Three baseline models were trained against the same training/test split as the deep learning model to contextualize performance: (1) a clinical model using T category, N category, HPV/p16 status, age, sex, and smoking history; (2) a volume model using the volume (mm3) and largest diameter of the largest nodal gross tumour volume (GTVn); and (3) a mixed clinical + volume model using features from both models. Each baseline was a logistic regression model with L2 regularization, fit separately within each of the four cross-validation training folds. Categorical variables were one-hot encoded; continuous variables were standardized using training-set means and standard deviations. Predictions on the held-out test set and external Maastro cohort were averaged across the four cross-validation folds, matching the deep learning ensemble.

Patient-level iENE Model Training. The iENE model is built on the ResNet18 architecture He 2016 with ACS convolutions Yang 2021, initialized with ImageNet pretrained weights Deng 2009. The ResNet18 architecture with ACS convolutions was selected to balance feature extraction capabilities with computational efficiency, ensuring the model remains lightweight enough for rapid clinical deployment and inference in resource-constrained hospital environments. The model input is a treatment planning CT centered around the larynx, cropped to voxel dimensions of 256x256x128, with 1mm isotropic spacing on the XY plane and original slice thickness of the acquisition. The training set was split into 4-folds for cross-validation and to train separate models on each data split, serving as biological replicates. Each model was initially trained for 150 epochs with a batch size of 16, data augmentation of random rotation, dropout of 0.4, a learning rate of 10-3 with the Adam optimizer with weight decay, using the binary cross-entropy loss function with class imbalance weight of 4.48 applied to iENE-positive cases Kingma 2015. For each fold, we conducted triplicate training runs of the model, serving as technical replicates. The best performing checkpoint was selected based on the sum of the AUROC and AUPRC on the fine-tuning portion of each fold. A subsequent fine-tuning run of 100 epochs was performed for each model replicate with a lower learning rate, and the best model checkpoint across all technical replicates within each fold was selected based on the same aforementioned metrics. This checkpoint is saved as the final model for each fold, resulting in four trained models total.

iENE Model Inference. All code and model weights used to perform inference of iENE is available on GitHub: https://github.com/skim2257/iENE_infer/. Inference of iENE on unseen data occurs in two steps: larynx segmentation and iENE inference. The nnU-Net larynx segmentation model requires the medical images to be in NIfTI format. An optional step of processing raw DICOM images to NIfTI format can be performed via Med-ImageTools, which is executable via pixi, as configured in the ‘iENE_infer’ repository Kim 2025. The larynx segmentation model inference is performed using the nnU-Net’s default settings, and the predicted masks are saved in a user-specified output directory. The predicted larynx is used to define the bounding box used to crop the model input for the iENE model Isensee 2021. We employ test-time augmentation (TTA) to add minor variances to the model input, providing insights about model uncertainties and improving predictive accuracy Ayhan 2018Shanmugam 2021. Six translations, 12 voxels in both directions for each of the three axes, are applied to each image, yielding a total of seven inferences per image. Since inferences are generated with TTA for each of the four models, each sample will have 28 predicted probabilities of iENE. While there are a variety of ways to aggregate multiple predictions into a final probability of iENE, we take the simple average of 28 predictions, as we do not have extensive held-out testing data to calibrate or meta-learn the weighted importances of each “configuration” of predictions.

Statistical Analysis. Where a binary determination was required, a patient was declared model-iENE-positive when this probability was at or above a decision threshold τ. The primary threshold, τ = 0.5, is the conventional decision boundary for a classifier trained with binary cross-entropy. We examined additional thresholds, at τ = 0.25 as sensitivity-favoring, screening operating point and τ = 0.75 as specificity-favoring, staging operating point. For our statistical analyses, the same thresholds were uniformly applied to both cohorts without recalibration. Because predicted probabilities were not recalibrated to each cohort’s iENE prevalence, a given threshold does not correspond to a fixed sensitivity or specificity across cohorts. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated at each threshold in both cohorts, with Wilson 95% CIs (Table 4.6).

Because ENE is more frequent in larger lymph nodes, an image-based model could achieve high discrimination by learning nodal size alone. To characterize the extent to which the model’s output reflects nodal size, we computed Pearson and Spearman correlations between the predicted probability and the volume of the patient’s largest nodal gross tumour volume (GTVn) on the RADCURE held-out set. GTVn volumes were derived from the clinical treatment-planning contours, which were used only for this analysis and for the volume baseline and are not required by the model.

Survival was estimated with the Kaplan-Meier method and compared between groups with the log-rank test. 95% CIs for AUROC and AUPRC were estimated with 100 bootstrap resamples of patients. Differences in AUROC and AUPRC were estimated on the RADCURE held-out set with a paired bootstrap of 2,000 draws, in which each draw scores all models on the same resample, since two models tested on the same patients need a paired comparison DeLong 1988. For each of the six pairwise comparisons among the deep learning model and the three baselines, we report the difference, its 95% bootstrap interval and a two-sided p-value (Supp.Table 4). Unadjusted hazard ratios (HRs) with 95% CIs for distant control were estimated with separate univariable Cox proportional hazards models for the radiologist’s determination and for the model’s prediction at each threshold. The same models were fitted for the volume baseline thresholded at the same values of τ (Supp.Table 5).

Negative control ablation analysis. A correlation with volume describes an association and does not show which part of the image the model reads. We therefore applied the READII-2-ROQC negative controls (Ch.3.4) to the trained model, with two definitions of the region of interest analysed separately: the patient’s largest GTVn and the primary gross tumour volume (GTVp). GTVp is contoured tumour in the same image but is not where iENE is assessed, so a response that is specific to the node should not appear when primary tumour is perturbed. Three permutations (Shuffle, Sample and Random) were each applied to three regions: the ROI, the image outside the ROI (non-ROI, the Background region of Ch.3.4) and the full image, giving nine perturbed copies of each planning CT in the RADCURE held-out set for each ROI definition. Patients without GTVp or GTVn contours were excluded from both analyses, so that the two sets of controls are compared on the same patients (n=142). The negative controls were passed through the same inference pipeline as the originals and each control’s AUROC was calculated against the radiologist’s determination, the Pearson correlation between predictions on the original and control images, and the standard deviation of the per-patient residual, defined as the original minus the control prediction (Figure 4.3, Supp.Table 6). Following Chapter 3.4, we hypothesized that if the model’s output depends on image content beyond nodal size, a control that destroys that content will lower discrimination, and that the region in which perturbation causes the loss indicates where the signal lies.

Error profiling. To examine where the model fails in an external cohort, we compared the two cohorts across their clinical characteristics and acquisition geometry with Mann-Whitney, chi-square or Fisher exact tests and standardized differences (Supp.Table 7). Within the Maastro cohort, AUROC with 95% CIs from 2000 stratified bootstrap resamples and error rates at τ=0.50 were estimated by subgroup (Supp. Table 8, Supp. Figure 3). False negatives and false positives were each tested against label modality and the same clinical/acquisition factors, with the aforementioned tests and logistic regression (Supp. Table 9). Whether a factor changed the relation between score and label was tested with a likelihood-ratio test of the interaction between the model’s probability output and the clinical/acquisition factor. P-values were adjusted by the Benjamini-Hochberg method and are reported as q. It is important to note that these post-hoc analyses are not meant to be new findings, but are exploratory.

Calibration and decision curve analysis. Calibration was assessed in both cohorts with a logistic calibration model, reporting the calibration slope, intercept and calibration in-the-large with Wald 95% CIs, the Brier score, and a grouped calibration error over eight quantile groups of the predicted probability Van Calster 2019. Clinical utility was assessed by decision curve analysis with distant failure within 2 years as the outcome Vickers 2006. Each strategy selects a group of patients to treat as high risk: the radiologist’s iENE determination, the model’s determination at τ = 0.25, 0.50 and 0.75, and the volume baseline at the same thresholds in the RADCURE held-out set. They were compared with treating all patients as high risk (treat all) and none (treat none). Net benefit weighs the selected patients who develop distant failure against those who do not, at the exchange rate implied by the threshold probability, which is the 2-year risk of distant failure at which a clinician would act. The 2-year risk in each selected group was estimated by the Kaplan-Meier method Vickers 2008. Threshold probabilities ran from 0.01 to 0.30, net benefit is tabulated at 0.10, and 95% CIs are percentile intervals from 2000 stratified bootstrap resamples. Because each strategy is a fixed rule, the analysis does not treat the model’s score as a probability and is reported for both cohorts.

4.3Results

We developed a patient-level deep learning model that predicts radiologist-determined iENE directly from treatment-planning CT, requiring no manual lymph node segmentation. The model was trained and internally validated pseudo-prospectively on the RADCURE cohort by splitting based on diagnosis date and externally validated on the independent Maastro cohort. Cohort characteristics are summarized in Table 4.1 Welch 2024.

Table 4.1Dataset breakdown of RADCURE and Maastro cohorts. The RADCURE cohort is split into training (n=752) and held-out test (n=163) sets, with the Maastro cohort (n=175) used in full as the external validation set. Categorical variables are reported as count (percentage), with percentages calculated relative to the column total. Median follow-up time is reported in days with the interquartile range in parentheses. iENE: imaging-based extranodal extension; HPV: human papillomavirus; IQR: interquartile range; RT: radiation therapy; EGFRI: epidermal growth factor receptor inhibitor; AJCC: American Joint Committee on Cancer.
RADCUREMaastro
Training
n=752
Test
n=163
Total
n=915
External
n=175

Sex

Female

Male

130 (17.3%)

622 (82.7%)

42 (25.8%)

121 (74.2%)

172 (18.8%)

743 (81.2%)

44 (25.1%)

131 (74.9%)

Median age in years (IQR)

60 (54-68)

63 (56-70)

61 (54-68)

62 (56-68)

Smoking history

≥10 pack-years

<10 pack-years

460 (61.2%)

292 (38.8%)

103 (63.2%)

60 (36.8%)

563 (61.5%)

352 (38.5%)

128 (73.1%)

47 (26.9%)

HPV/p16 status

Negative

Positive

Unknown

202 (26.9%)

536 (71.3%)

14 (1.9%)

52 (31.9%)

109 (66.9%)

2 (1.2%)

254 (27.8%)

645 (70.5%)

16 (1.7%)

74 (42.3%)

101 (57.7%)

0 (0.0%)

T category (UICC/AJCC 8th)

T0

T1

T2

T3

T4+

1 (0.1%)

130 (17.3%)

279 (37.2%)

208 (27.5%)

134 (17.8%)

0 (0.0%)

33 (20.2%)

48 (29.4%)

48 (29.4%)

34 (20.8%)

1 (0.1%)

163 (17.8%)

327 (35.7%)

256 (28.0%)

168 (18.3%)

0 (0.0%)

28 (16.0%)

48 (27.4%)

35 (20.0%)

64 (36.6%)

N category (UICC/AJCC 8th)

N0

N1

N2

N3

118 (15.7%)

56 (7.4%)

529 (70.3%)

49 (6.5%)

28 (17.2%)

22 (13.5%)

107 (65.6%)

6 (3.7%)

146 (16.0%)

78 (8.5%)

636 (69.5%)

55 (6.0%)

0 (0.0%)

93 (53.1%)

78 (44.6%)

4 (2.3%)

Overall stage

I

II

III

IV

377 (50.1%)

159 (21.1%)

79 (10.5%)

137 (18.2%)

80 (49.1%)

30 (18.4%)

17 (10.4%)

36 (22.1%)

457 (49.9%)

189 (20.7%)

96 (10.5%)

173 (18.9%)

43 (24.6%)

24 (13.7%)

45 (25.7%)

63 (36.0%)

Median follow-up time in days (IQR)

1646 (958-2148)

959 (618-1120)

1444 (854-2030)

1620 (904-2488)

Treatment type

RT

RT+Chemo

RT+EGFRI

332 (44.2%)

386 (51.3%)

34 (4.5%)

78 (47.8%)

81 (49.7%)

4 (2.5%)

410 (44.8%)

467 (51.0%)

38 (4.2%)

59 (33.7%)

116 (66.3%)

0 (0.0%)

Contrast enhanced

Yes

No

556 (73.9%)

196 (26.1%)

140 (85.9%)

23 (14.1%)

696 (76.1%)

219 (23.9%)

Not available

Slice Thickness (min-max, mean in mm)

2.0-2.5 (2.10)

2.0-2.5 (2.04)

2.0-2.5 (2.09)

3.0 (3.0)

iENE

Yes

No

142 (18.9%)

610 (81.1%)

25 (15.3%)

138 (84.7%)

167 (18.3%)

748 (81.7%)

60 (34.3%)

115 (65.7%)

The final iENE model is a ResNet18 architecture with ACS convolutions, trained across 4 folds of the 752-patient training dataset He 2016Yang 2021. To account for technical variability, we trained 3 technical replicates on each fold for 150 epochs and selected the best checkpoint by the sum of AUROC and AUPRC on the fine-tuning portion of each fold. The selected checkpoints were finetuned for an additional 100 epochs. The best fine-tuned checkpoint per fold was chosen to compose the final ensemble and calculate the following results.

Figure 4.1Performance evaluation of the iENE predictive model on the RADCURE held-out set using (left) the receiver operating characteristic curve and (right) the precision-recall curve, comparing the deep learning model with baseline models trained on clinical features, GTVn volume, and the mixed of the two (see Methods, Baseline comparison models). These figures were generated on the held-out set of RADCURE.
Table 4.2Performance of the deep learning and baseline models on the RADCURE held-out test set. Area under the receiver operating characteristic curve (AUROC) and area under the precision-recall curve (AUPRC) are reported for the deep learning model and the three baseline models (clinical, volume, and mixed), with 95% confidence intervals in brackets. Confidence intervals were estimated by bootstrap resampling.
Model AUROC AUPRC
Deep Learning 0.913 [0.852–0.961] 0.603 [0.470–0.817]
Mixed 0.786 [0.685–0.878] 0.474 [0.338–0.686]
Volume 0.851 [0.773–0.921] 0.498 [0.373–0.713]
Clinical 0.681 [0.575–0.782] 0.322 [0.214–0.495]

On the RADCURE held-out test set, the deep learning model had the highest point estimates for AUROC (0.913) and AUPRC (0.603), followed by volume baseline (0.851 and 0.498; Figure 4.1, Table 4.2). In paired bootstrap comparisons on the same patients, our model’s AUROC was higher than that of clinical and mixed baselines (Supp. Table 4). The difference from the volume baseline was smaller and its confidence interval included zero (+0.062 [–0.004 to +0.134], p=0.067). The deep learning’s AUPRC tells a similar story, but was not distinguishable from the volume baseline (+0.105 [–0.109 to +0.302], p=0.334). The volume baseline was itself higher than the clinical and mixed baseline on AUROC and only the clinical baseline on AUPRC. The deep learning model’s AUPRC was approximately four times the random-classifier baseline of 0.153.

Because larger nodes are more likely to harbor ENE, we next assessed whether the model acts as a surrogate for nodal size. The model’s output correlates moderately with the volume of the patient’s largest locoregional lymph node (GTVn), with Pearson r=0.335 and Spearman ρ=0.587 (Figure 4.2). Although statistically significant, this association leaves most of the variation in model output unexplained by volume.

Figure 4.2Scatterplot of the model’s predicted probability against volume (in mm3) of the largest locoregional lymph node (GTVn), colored by radiologist iENE determination (iENE+=red, iENE–=blue).

It is also important to consider the model’s performance on ambiguous samples, by observing outliers. The scatterplot shows expected false positives at larger GTVn volumes, and false negatives with smaller GTVn volumes, but the model also confidently rejects several cases with extremely large GTVn volumes, avoiding false positives that a volume-based model would not reject, demonstrating that the model integrates signal beyond size (Figure 4.2).

Figure 4.3Violin plots for evaluation of iENE model with READII-2-ROQC negative control images. The ROI is (a) the largest locoregional lymph node gross tumour volume and (b) the primary gross tumour volume. Violins show bootstrap AUROC distributions on the RADCURE held-out set. The center point of the violins mark the observed AUROC in the analysis set, which excludes patients without a GTVn contour. The red line marks the AUROC of the volume model and the dotted line marks chance.

The READII-2-ROQC negative controls helped locate the relevant image content behind the model’s predictions (Figure 4.3, Supp. Table 6). On the original images, the AUROC was 0.908, and shuffling or resampling GTVp left the model’s output essentially unchanged from the original whereas the same controls applied to the largest GTVn moved individual predictions further. Replacing the ROI with uniform random intensities further lowers the AUROC, down to 0.865 for the largest GTVn (p=0.025). Individual predictions moved further when the node was replaced (r=0.793; residual SD 0.172) than when the primary tumour was (r=0.966; residual SD 0.071). Perturbations outside the ROI entirely removed any prediction power for both GTVn and GTVp, whether the ROI was left intact (non-ROI) or perturbed as well (full). An intact largest node was therefore not sufficient for the model to find any meaningful insights, and neither was an intact primary tumour.

Performance of the model on the external validation set was stratified by the image modality used to clinically determine iENE (Figure 4.4, Table 4.3). The model performs best and most consistently on labels determined by CT or MRI, and moderately on PET-CT-determined labels. We note that the CT-labeled subset is small (n=21), and the AUROC and AUPRC estimates on this subset carry wide uncertainty; bootstrap confidence intervals are reported in Table 4.3 to quantify this. Modality-stratified performance should therefore be interpreted as indicative rather than definitive, with the aggregate evaluation across the full Maastro cohort (n=175) providing the most stable estimate of the model's external generalization.

Figure 4.4Comparative analysis of the iENE model performance on the Maastro external validation dataset. The top row shows receiver-operating characteristic (ROC) curves and the bottom row shows precision-recall curves (PRC). Each column corresponds to ground truths derived from CT, PET-CT, or MRI. Parentheses denote sample size per label and positive class rate.
Table 4.3Modality-stratified performance of the deep learning model on the Maastro external validation set. AUROC and AUPRC are reported for the full Maastro cohort and separately for the subsets whose ground-truth iENE labels were determined by CT, PET-CT, or MRI, with 95% confidence intervals in brackets estimated by bootstrap resampling. The number of patients and positive (ENE+) cases per subset are shown. The CT-labeled subset is small (n=21) and its estimates carry wide uncertainty; modality-stratified values should be interpreted as indicative, with the aggregate (n=175) providing the most stable estimate of external performance.
Modality n (ENE+) AUROC AUPRC
Overall 175 (60) 0.671 [0.579–0.763] 0.602 [0.498–0.719]
CT 21 (8) 0.769 [0.538–0.952] 0.735 [0.523–0.934]
PET-CT 79 (28) 0.571 [0.422–0.717] 0.587 [0.454–0.732]
MRI 75 (24) 0.749 [0.627–0.864] 0.598 [0.461–0.794]

Interactive · Tables 4.2 and 4.3

How the iENE model compares

Point estimates with 95% bootstrap confidence intervals. Dashed ticks mark what a random classifier would score.

Compared with RADCURE, the Maastro cohort differed more in acquisition geometry than in clinical characteristics (Supp.Table 7). At τ=0.50 the model had 23 false-negatives and 33 false positives. Of the factors examined, the reconstructed axial field of view (FOV), which sets the in-plane pixel spacing, had the strongest association with both kinds of error (Supp.Tables 8–9, Supp.Fig 3). In the 68 scans reconstructed above 500mm, the model missed 17 of 24 iENE-positive (71%), against 6 of 36 at 500mm or less (17%, q<0.001), and wrongly flagged 5 of 44 iENE-negative patients (11%), against 28 of 71 (39%, q=0.006). FOV also changed the relation between score and label (p=0.003, q=0.013 from Supp.Table 9).

Label modality was associated with more false negatives (q=0.049), but the likelihood-ratio test of the score-by-modality interaction was not significant after adjustment (p=0.028, q=0.056). The two factors were related, since 38 of the 79 PET-CT labels were scanned above 500mm (AUROC 0.511) against 30 of the other 96, and AUROC fell only where they coincided (AUROC 0.779 in PET-CT, 500mm or less from Supp.Table 8).

To assess the prognostic value of the model’s outputs, we evaluate Kaplan-Meier (KM) survival curves using simulated deployment data at specific thresholds. Distant control was selected as the endpoint of interest because ENE is mechanistically and clinically linked to distant metastatic spread rather than to local failure, and because overall survival in this predominantly HPV-positive, favorable-prognosis population is diluted by competing causes of death and by long survival times that limit event counts within available follow-up Huang 2020. While the two sets of predictions are not fully independent from each other since the model was trained using the clinician’s determination as ground truth, this analysis serves as a sanity check to understand whether the model recapitulates the training labels or captures independent prognostic signals. Using the primary decision threshold of τ=0.5 to visualize distant control outcomes, on the RADCURE held-out set (Figure 4.5a), the model’s predictions separated high and low-risk groups (p<4.0-9), as did the radiologist’s determination (p<1.49-7). Separation remained significant in the external validation set across all labeling modalities (p<2.46-4).

Figure 4.5Kaplan-Meier curves for distant control comparing high-risk versus low-risk group stratification based on iENE determination. Left column: stratification by a clinician’s iENE determination. Right column: stratification by the deep learning model’s prediction at τ=0.5. Analyses are presented for both the RADCURE held-out set (top row) and the external validation set (bottom row). Log-rank p-values and numbers at risk are shown for each survival curve.
Figure 4.6Kaplan-Meier curves for distant control comparing high-risk versus low-risk group stratification based on iENE determination across multiple thresholds (τ=[0.25, 0.50, 0.75]). The left most curves show the curves based on the clinician’s iENE determination. Analyses are presented for both the RADCURE held-out set (top row) and the Maastro external validation dataset (bottom row). Log-rank p-values are shown for each threshold. Numbers at risk are shown below each curve.
Figure 4.7Kaplan-Meier curves for distant control comparing high-risk versus low-risk group stratification in HPV-positive/negative cohorts based on iENE determination across multiple thresholds (τ=[0.25, 0.50, 0.75]). The left most curves show the curves based on the clinician’s iENE determination. Each subfigure has two rows: top row with the HPV-positive subgroup and the bottom row with the HPV-negative subgroup. Analyses are presented for both the held-out dataset (Figure 4.7a, top grid) and the Maastro external validation dataset (Figure 4.7b, bottom grid). Log-rank p-values are shown for each threshold. Numbers at risk are shown below each curve.
Table 4.4Distribution of iENE+ versus iENE− cases within the HPV+ subpopulation of each subgroup, under the radiologist's clinical determination and at model thresholds τ=[0.25, 0.50]. Cells report count (percentage within column total). RADCURE: held-out test set (n=109). Maastro: external validation set (n=101)
RADCURE HPV+ (n=109) τ=0.25 (n=30) τ=0.50 (n=17) Maastro HPV+ (n=101) τ=0.25 (n=67) τ=0.50 (n=40)
iENE+ 15 (13.8%) 12 (40.0%) 9 (52.9%) 37 (36.6%) 28 (41.8%) 21 (52.5%)
iENE– 94 (86.2%) 18 (60.0%) 8 (47.1%) 64 (63.4%) 39 (58.2%) 19 (47.5%)

Interactive · Table 4.4

Choosing an operating point in HPV-positive disease

Each dot is one HPV-positive patient. Filled dots were iENE-positive on the radiologist’s read. Ringed dots are the patients the model flags at the chosen threshold.

RADCURE held-out · HPV+ n=109

Maastro external · HPV+ n=101

Counts are exact from Table 4.4. Dot order is illustrative.

To explore prognostic separation across a range of operating points, we evaluate Kaplan-Meier survival curves for distant control at multiple decision thresholds (τ > [0.25, 0.50, 0.75]), simulating deployment configurations that trade sensitivity against specificity. Across all patients (Figure 4.6), higher thresholds yield more conservative, higher-specificity iENE declarations, while lower thresholds flag a larger proportion of patients for radiologist review.

Table 4.5Unadjusted hazard ratios for distant control by radiologist-determined and model-predicted iENE. Model-positive patients had a predicted probability of at least τ. Each hazard ratio is from a separate univariable Cox model, with distant control timed from the start of radiotherapy and censoring at last follow-up. RADCURE held-out test set: n=163, 22 events; Maastro external validation set: n=175, 27 events. iENE=imaging-based extranodal extension. *Estimated with an L2-penalised Cox model because the unpenalised model did not converge.
iENE Label Source HR (95% CI)
RADCURE (n=163) Maastro (n=175)
Radiologist 7.03 (3.03–16.35) 2.94 (1.38–6.30)
τ = 0.25 5.07 (2.16–11.87) 1.82 (0.73–4.51)
τ = 0.50 8.30 (3.58–19.25) 4.15 (1.82–9.49)
τ = 0.75 *6.29 (2.58–15.35) 8.04 (2.99–21.59)

In unadjusted Cox models (Table 4.5), model-defined iENE was associated with worse distant control at every threshold in the RADCURE held-out set and τ > [0.50, 0.75] in the Maastro cohort, which held similar to the radiologists’ determinations. Thresholding the volume baseline at the same values gave hazard ratios of 4.56 (95% CI 1.83–11.37), 2.99 (0.69–12.93) and 1.62 (0.22–12.13) at τ = 0.25, 0.50 and 0.75 in the RADCURE held-out set (Supp.Table 5). These intervals included 1 at τ = 0.50 and 0.75 and overlapped those of the deep learning model at every threshold. Separation was consistent in early and late-stage disease (Supp.Figure 1) and was also examined by HPV/p16 status (Figure 4.7, Table 4.4) and jointly by HPV status and stage (Supp.Figure 2), which isolates the HPV-positive early-stage subgroup most relevant to the E3311 trial design.

The operating characteristics of the three thresholds are given in Table 4.6. In the RADCURE held-out set, τ=0.25 flagged 40 of 163 (24.5%) and identified 21 of 25 iENE-positive patients. At τ=0.75, the model called 12 patients positive, of whom 8 were iENE-positive. The same thresholds behaved differently in the Maastro cohort. At τ=0.25 the model flagged 118 of 175 patients (67.4%) and identified 46 of 60 iENE-positive patients. At τ=0.75 it called 8 patients positive, of whom 6 were iENE-positive.

Table 4.6Operating characteristics of the deep learning model at three decision thresholds. A patient was called positive when the predicted probability was at least τ, and calls were compared with the radiologist’s iENE determination. Values are estimates with Wilson 95% CIs. The thresholds were applied to both cohorts without recalibration. PPV: positive predictive value; NPV: negative predictive value; TP: true positives; FP: false positives; TN: true negatives; FN: false negatives.
τ Sensitivity Specificity PPV NPV TP / FP / TN / FN
RADCURE held-out set (n=163; 25 iENE-positive)
0.25 0.84 (0.65–0.94) 0.86 (0.79–0.91) 0.53 (0.37–0.67) 0.97 (0.92–0.99) 21 / 19 / 119 / 4
0.50 0.60 (0.41–0.77) 0.93 (0.88–0.97) 0.63 (0.43–0.79) 0.93 (0.87–0.96) 15 / 9 / 129 / 10
0.75 0.32 (0.17–0.52) 0.97 (0.93–0.99) 0.67 (0.39–0.86) 0.89 (0.83–0.93) 8 / 4 / 134 / 17
Maastro external cohort (n=175; 60 iENE-positive)
0.25 0.77 (0.65–0.86) 0.37 (0.29–0.47) 0.39 (0.31–0.48) 0.75 (0.63–0.85) 46 / 72 / 43 / 14
0.50 0.62 (0.49–0.73) 0.71 (0.62–0.79) 0.53 (0.41–0.64) 0.78 (0.69–0.85) 37 / 33 / 82 / 23
0.75 0.10 (0.05–0.20) 0.98 (0.94–1.00) 0.75 (0.41–0.93) 0.68 (0.60–0.74) 6 / 2 / 113 / 54

Calibration differed between the cohorts (Figure 4.8, Table 4.7). In the RADCURE held-out set the mean predicted probability was 0.176 against an iENE prevalence of 0.153 with a Brier score of 0.083 against 0.130 for a constant prediction at the prevalence. In the Maastro cohort the calibration slope was 0.33 (95% CI 0.11–0.55), an interval that excludes 1, indicating the predicted probabilities were too extreme. iENE was more frequent than predicted among low-scoring patients and less frequent than predicted across most of the upper range. The mean predicted probability was 0.397 against an iENE prevalence of 0.343 with a Brier score of 0.226, which was no better than 0.225 of a constant prediction at the prevalence. The group calibration error for the RADCURE held-out set was at 0.048 against 0.168 for the Maastro cohort.

Figure 4.8Calibration of the deep learning model’s predicted probability in the RADCURE held-out set and the Maastro external cohort. Observed iENE frequency is plotted against predicted probability in eight quantile bins (circles) and in fixed bins of width 0.1 (points joined by lines). The red curve is the logistic calibration fit and the dashed line marks perfect calibration. The intercept shown in each panel is from the joint fit with the slope; calibration-in-the-large is given in Table 4.7. Values in brackets are 95% CIs.
Table 4.7Calibration of the deep learning model in the RADCURE held-out set and the Maastro external cohort. Intervals are Wald 95% CIs. The reference Brier score is that of a constant prediction at the cohort prevalence, and the scaled Brier score is one minus the ratio of the model’s Brier score to the reference. Grouped calibration error is the mean absolute difference, weighted by group size, between observed frequency and mean predicted probability in eight quantile groups, with the largest single difference in parentheses.
RADCURE held-out set (n=163) Maastro external cohort (n=175)
iENE prevalence 0.153 0.343
Mean predicted probability 0.176 0.397
Brier score 0.083 0.226
Reference Brier score (prevalence only) 0.130 0.225
Scaled Brier score 0.364 −0.004
Calibration-in-the-large (95% CI) −0.30 (−0.87 to 0.28) −0.31 (−0.67 to 0.05)
Calibration slope (95% CI) 0.91 (0.59 to 1.22) 0.33 (0.11 to 0.55)
Calibration intercept (95% CI) −0.36 (−0.95 to 0.23) −0.47 (−0.81 to −0.14)
Grouped calibration error (maximum) 0.048 (0.147) 0.168 (0.280)

Decision curves of 2-year distant failure are shown in Figure 4.9 and net benefit at a threshold probability of 0.10 is on Table 4.8. The 2-year risk of distant failure was 0.134 in the RADCURE held-out set and 0.120 in the Maastro cohort, and treating all patients as high risk has no net benefit at threshold probabilities above these values. In the RADCURE held-out set the 24 patients called positive by the model at τ=0.50 had a 2-year risk of 0.50, against 0.47 for the 25 patients the radiologist called iENE-positive, and net benefit at a threshold probability of 0.10 was 0.065 and 0.063, respectively. At τ=0.25 the model selected more patients at a lower risk (40 patients, 0.34) for a similar net benefit at 0.10 (0.065), which fell below that of τ=0.50. At τ=0.75 it selected 12 patients at a risk of 0.61, with a lower net benefit (0.042). Treating all patients gave 0.037 and the volume baseline at τ=0.50 selected 8 patients at a risk of 0.31 for a net benefit of 0.012. In the Maastro cohort the model at τ=0.50 selected 70 patients at a 2-year risk of 0.23 against 0.24 for the 60 radiologist-positive patients, and net benefit was 0.056 and 0.052, respectively. At τ=0.25 and τ=0.75, the model selected 118 and 8 of 175 patients at a risk of 0.13 and 0.60, for similar net benefit (0.025 and 0.025) as treating all patients (0.022).

Figure 4.9Decision curves for distant failure within 2 years in the RADCURE held-out set and the Maastro external cohort. Net benefit of flagging high-risk patients selected by the radiologist’s iENE determination and the deep learning model across three thresholds, compared with treating all patients and treating none. The volume baseline across three thresholds are also considered in the RADCURE held-out set. The threshold probability is the 2-year risk of distant failure at which a clinician would act.
Table 4.8Net benefit for distant failure within 2 years at a threshold probability of 0.10. Selected is the number of patients the strategy treats as high risk, and 2-year risk is the risk of distant failure among them. Model and Volume are the determinations of the deep learning model and the volume baseline at threshold τ. The volume baseline was not evaluated in the Maastro cohort.
Strategy RADCURE held-out set (n=163) Maastro external cohort (n=175)
Selected 2-year risk Net benefit (95% CI) Selected 2-year risk Net benefit (95% CI)
Radiologist 25 0.47 0.063 (0.031 to 0.093) 60 0.24 0.052 (0.019 to 0.087)
Model, τ = 0.25 40 0.34 0.066 (0.034 to 0.096) 118 0.13 0.025 (−0.009 to 0.060)
Model, τ = 0.50 24 0.50 0.065 (0.034 to 0.097) 70 0.23 0.056 (0.021 to 0.089)
Model, τ = 0.75 12 0.61 0.042 (0.015 to 0.072) 8 0.60 0.025 (0.003 to 0.055)
Volume, τ = 0.50 8 0.31 0.012 (−0.005 to 0.037) – – –
Treat all 163 0.134 0.037 (0.015 to 0.056) 175 0.120 0.022 (−0.009 to 0.051)
Treat none 0 – 0 0 – 0

4.4Chapter discussion

Reliable determination of iENE is crucial to effective HNSCC staging. Clinically overt ENE was incorporated into the 8th edition UICC/AJCC criteria for non-viral HNSCC but was explicitly not a staging factor for HPV-positive oropharyngeal carcinoma O'Sullivan 2017. It is not equivalent to iENE, a radiologic determination that captures earlier extranodal spread, such as perinodal fat infiltration or nodal coalescence, which would not meet clinical criteria Henson 2024. Unequivocal iENE is now incorporated into the 9th edition clinical N classification for HPV-associated oropharyngeal carcinoma, yet it remains difficult to determine consistently Huang 2025Brierley 2025Brierley 2026Sahin 2025. Pathologic ENE is unavailable in the majority of patients treated non-surgically and cannot inform the initial treatment decision, while radiologic iENE requires substantial expert training and is subject to meaningful interobserver variability Sahin 2025. In this study we developed a deep learning model that addresses this gap in three ways. First, it predicts iENE at the patient level and is trained directly on radiologist-determined iENE labels rather than pathologic ENE, so its output is interpretable on the same scale as the clinical determination it is intended to support. Second, it operates on radiation treatment-planning CT, imaging that is already routinely acquired for every patient, allowing direct deployment within the radiotherapy workflow without additional imaging or manual lymph node segmentation. Third, the full pipeline, trained weights, and software environment are released as open-source, reproducible resources. Together these choices distinguish our approach from prior AI-based ENE work and make the model clinically applicable as defined in chapter 1.12.

Our approach differs from prior AI-based ENE work in both the prediction target and the supervision signal, with implications for clinical interpretability and downstream utility. Kann and colleagues' original work, and the subsequent AI-ENE extension by Ye and colleagues, predict ENE at the level of individual lymph nodes using an auto-segmentation pipeline to enable end-to-end inference Kann 2018Kann 2020Ye 2026. Dayan and colleagues sit between these approaches, supervising on radiologist-determined iENE, but still classifying from a segmented lymph node, in a single-centre HPV-positive cohort without external validation Dayan 2026. Because these node-level models are trained with pENE as ground truth, they learn from a surgically treated population that is non-representative of the broader HNSCC cohort, much of which is treated non-surgically. Patient-level aggregation reported by Ye and colleagues yields at least one AI-ENE-positive node in 70.8% of cases, roughly four times the 15–20% iENE prevalence reported in radiologic series including our own, suggesting a model that is highly sensitive but not tuned to a clinically actionable specificity Huang 2020Ye 2026. Without an iENE ground truth to anchor the patient-level aggregation, AI-ENE outputs cannot be directly compared to a radiologist's determination and are difficult to integrate into staging frameworks such as the 9th edition TNM, which is defined relative to iENE rather than pENE or AI-ENE Huang 2025O'Sullivan 2020.

In contrast, our model is anchored to radiologist-determined iENE and retained above-chance discrimination on both the internal held-out and external validation sets, albeit with a substantial drop externally. The Kaplan-Meier analyses indicate that its stratification of high- and low-risk patients is comparable with that of the radiologist's determination on which it was trained. The hazard-ratio intervals of the two overlapped at every threshold in both cohorts (Table 4.5), and the comparison is not a formal test of equivalence. This separation, however, primarily reflects specificity at the chosen operating point and does not directly characterize sensitivity, which must be assessed separately when considering deployment (Table 4.6). Future work could examine whether combining the two paradigms, by using a sensitive node-level model to flag candidate locoregional nodes and a specific patient-level model to confirm clinically meaningful iENE, could outperform either approach alone, particularly for isolating high-risk subpopulations within HPV-positive disease.

Nodal volume alone was a strong predictor of iENE (AUROC 0.851), and our data do not show that the deep learning model outperforms it. The model’s point estimates were higher on both AUROC and AUPRC, but the paired differences were not distinguishable from zero (Supp.Table 4). With only 25 iENE-positive patients in the held-out test set, the comparison was underpowered and is inconclusive rather than evidence of equivalence. The interval for the AUROC difference is compatible with no difference and with an advantage of up to 0.13 for the deep learning model. Larger, multi-institutional test sets and prospective validation are needed to resolve it. In practice, a volume model requires a clinician-drawn nodal contour, whereas the deep learning model requires none. Both models were higher than the clinical baseline on both metrics, so for an imaging model of iENE, the informative comparator is nodal size and not clinical variables, similar to Chapter 3’s conclusion from prognostic models (Ch.3.2.3).

The negative controls analysis approaches the question of nodal size from a different direction than the correlation and the volume baseline. The iENE model’s discrimination was lost whenever the image outside the largest node was perturbed, so its output depends on image content that those controls removed. Its predictions were only slightly changed when the interior of the largest node was shuffled or resampled. The model therefore makes little use of intranodal texture, and any sensitivity it has to interior content sits at the node and not at the primary tumour. This is anatomically plausible as iENE is defined at the nodal margins and beyond, by perinodal fat infiltration, nodal coalescence and invasion of adjacent structures, and not by the internal appearance of the node Henson 2024. Uniform random replacement shifted predictions more at the node than at the primary tumour (residual SD 0.172 and 0.071), and its fall in AUROC was distinguishable from zero only at the node (0.865, p=0.025 and 0.873, p=0.117), indicating that the model attends not to the primary tumour but the locoregional node.

Discrimination was lower in the Maastro cohort than in the RADCURE held-out set (AUROC 0.671 vs 0.913). AUPRC was nominally similar, but against a higher iENE prevalence (34.3% vs 15.3%), corresponding to a smaller gain over random chance (1.8x vs 3.9x) Saito 2015. The absence of cN0 patients from the Maastro cohort explains little since AUROC among RADCURE cN+ patients was 0.897, and labels read on diagnostic MRI or CT were not the difficulty, since the model ranked those patients better than patients labelled on the planning PET-CT (Table 4.3). Slice thickness (3.0mm vs 2.0–2.5mm) cannot be tested here, because it did not vary within the Maastro cohort. What separated the errors was the reconstructed field of view. Scans above 500mm, mostly coarser in-plane than any RADCURE scan, received lower scores whatever the label modality, so the same threshold gave a sensitivity of 83% at the narrow FOV and 29% at the wider, and an operating point would have to be set for each acquisition protocol and not only for each institution. AUROC dropped only among the 38 PET-CT labelled patients scanned at the wider FOV (AUROC 0.511) and was consistently higher in the other 137 patients (0.754). Furthermore, the calibration slope fell from 0.91 to 0.33, and the Brier score was no better than that of a constant prediction at the prevalence (Table 4.7).

This kind of miscalibration is expected when a model is moved to a cohort with a different case mix, prevalence, and labelling process, and calibration should be assessed, and the model updated at the new site Van Calster 2019. We did not recalibrate the model on the Maastro cohort, but recalibrating and evaluating on the same 175 patients may give optimistic estimates. However, since logistic recalibration changes the scale of the score and not the ranking of patients, it would not restore the discrimination that was lost (AUROC 0.671). A threshold chosen on RADCURE does not select the same kind of patients at another institution (Table 4.6), and local calibration is necessary before accepting the model’s output at its face-value probability.

The threshold analyses across subpopulations suggest that a single model can support distinct clinical use cases by selecting an appropriate operating point. At a high-specificity threshold, the model is intended to function as a staging and prognostication aid. This is particularly relevant for HPV/p16-negative patients under the 8th edition UICC/AJCC criteria, where clinically overt ENE directly influences stage assignment and surgical candidacy, as well as for the 9th edition’s incorporation of iENE for HPV-associated disease Huang 2025Brierley 2025Brierley 2026. For non-viral disease, the UICC 9th edition retains clinical ENE as the N3b criterion but now accepts unequivocal imaging findings as evidence for it Brierley 2025Brierley 2026. Whether an automated iENE determination can support that assessment in HPV/p16-negative HNSCC is a question our openly released pipeline makes testable in larger, non-viral cohorts. At a higher-sensitivity threshold, the model shifts into a screening role, flagging patients who warrant radiologist review for iENE, which is not consistently part of standard clinical practice today. In this configuration, the model enriches the review queue rather than replacing radiologist judgment, allocating expert attention toward cases most likely to harbor iENE. The ECOG-ACRIN 3311 trial of transoral surgery and de-intensified radiotherapy (RT) for HPV/p16-positive oropharyngeal cancer (OPC) illustrates this need: it enrolled participants without matted nodes, yet 31% received subsequent chemoradiotherapy after being classified high-risk on the basis of positive margins, ENE, or a high number of metastatic lymph nodes, and accurate pre-enrollment determination of iENE might have spared some of these patients from tri-modality treatment Ferris 2022. This pattern is not confined to trial populations: in a real-world SEER-Medicare cohort of locoregionally advanced HNSCC, the majority of resected patients (56%) went on to receive post-operative radiotherapy with or without systemic therapy, escalation that is frequently triggered by pathologic ENE Zheng 2025. Prospective validation is essential to translate these threshold analyses into deployment-ready parameters, with operating points tuned to each institutional workflow and clinical question.

Beyond model performance, an essential contribution of this study lies in the reproducibility and accessibility of the solution. This work is developed entirely on publicly accessible datasets from The Cancer Imaging Archive Clark 2013, and the iENE labels and train/test split for RADCURE are released via its clinical spreadsheet on TCIA, allowing any researcher to reproduce this study end-to-end and iterate on our findings Welch 2024. The full training and inference codebases, along with trained model weights, are publicly available, with environment specifications managed by pixi for single-command installation in a carbon copy of the authors' environment. Both raw DICOM images from clinical PACS and pre-processed NIfTI images are supported as input, via the open-source Med-ImageTools curation package Kim 2025.

4.4.1Limitations

Several limitations should be noted. Most importantly, RADCURE iENE labels came from a single radiologist, so the model inherits that reader’s thresholds and the interobserver variability documented for iENE Hoebers 2022Sahin 2025; multi-reader labels would better define the achievable ceiling. The pipeline’s main computational bottleneck is nnU-Net-based larynx segmentation Isensee 2021, though a lighter detection model may suffice given that the iENE model’s 7-fold TTA already buffers against minor crop variation Ayhan 2018Shanmugam 2021; architectural gains from attention mechanisms or added parameters are also constrained by our limited training set and overfitting risk, motivating future federated learning across institutions. Training relied on implicit radiologist determinations rather than the explicit four-tier criteria recently proposed by the Head and Neck Cancer International Group Henson 2024, and training models to directly predict for these endpoints would improve interpretability. The model was trained on oropharyngeal cancer only, limiting generalizability to other HNSCC subsites where treatment escalation is also common, and is restricted to CT input despite MRI's superior soft-tissue contrast and its use as a ground-truth modality in our external validation cohort Huang 2020. The comparison with the volume baseline rests on 25 iENE-positive patients in a single held-out set and is not available for the external cohort. Since the error profiling was post-hoc, we could test its findings directly by resampling the RADCURE held-out images to the Maastro geometry and rescoring them. Finally, the negative controls were applied at inference to a model trained only on unperturbed images, demonstrating that the model fails without the surrounding image but not what it reads there.

Chapter 5Supportive care29 min read · 11 figures · 6 tables

Dosarex, fully automated per-tooth dose reporting for osteoradionecrosis management

HypothesisPer-tooth dose reporting can be produced unattended from the planning DICOM study to help dentists make better informed and more granular decisions to manage tooth extraction and osteoradionecrosis.

14,564teeth from 712 patients given a planning dose on their panorex, with no manual contouring
1.07 Gymedian per-tooth difference between panorex and planning CT, 1.5% of a 70 Gy prescription
99.3%of teeth classified the same against the CDON extraction threshold

5.1Introduction

Osteoradionecrosis (ORN) of the jaw is a major late toxicity of head and neck radiotherapy (RT). Its reported prevalence varies widely, from 4–8% in the era of intensity-modulated radiotherapy (IMRT) and prophylactic dental care policies to as high as 40% in earlier reports Watson 2024. A multidisciplinary consensus by Buglione and colleagues identified poor dental health before RT and post-RT extraction of teeth in highly irradiated regions as the main risk factors for ORN. Although no randomized controlled trials have assessed the safety of extraction before or after RT, observational studies have generally reported higher rates of ORN after post-RT extraction, although three studies found no significant difference Buglione 2016. The ISOO-MASCC-ASCO guideline now advises a two-week healing period between extraction and the start of RT, provided this does not delay treatment where oncologic control would be compromised Peterson 2024.

Dose is the operative variable in pre-RT dental decisions. The Canadian Dental Oncology Network (CDON) guidelines recommend considering prophylactic extraction of teeth at risk that will receive 70 Gy or more in the maxilla or 60 Gy or more in the mandible Watson 2021, and the ISOO-MASCC-ASCO guideline recommends that the planned treatment volume and the anticipated dose to the mandible and maxilla be provided to the dentist before RT begins Peterson 2024. In practice, however, this dose is reported only for the whole jaw, so whether a given tooth exceeds its threshold, which is the quantity the dentist actually needs, is currently unavailable at the chairside.

Van Dijk and colleagues developed RADMAP, a semi-automated tool that divides the mandible and maxilla into 32 tooth-bearing regions using an angular ray-based algorithm and reports the mean dose per region as a table and a heat-mapped odontogram. Across 736 tooth locations in 23 patients, the mean dose to the automatically segmented alveolar regions correlated with that to manually contoured tooth roots (R² = 0.98), and the interobserver limits of agreement across six users were ±2.88 Gy in the mandibular alveolus. Tooth-region dose distinguished ORN-affected from unaffected sites (difference in means 12.4 ± 3.7 Gy, p = 0.0008), whereas whole-mandible mean dose did not (6.2 ± 4.3 Gy, p = 0.17). However, delineating the 32 tooth regions requires 35 to 120 minutes per patient depending on operator experience, and the interactive tool reduces this burden rather than removing it, which remains a major obstacle to routine per-tooth dose reporting van Dijk 2025.

A fully automated alternative is to display the planning dose directly on the panoramic radiograph (panorex) that dentists already use. This requires registering the planning CT to the panorex, which is challenging despite both modalities depicting the same dental anatomy. A panorex is acquired by a rotating source–detector system following a predefined focal trough, resulting in non-uniform, angle-dependent magnification and blur that vary with the position of anatomical structures relative to the trough Mallya 2018Rondon 2014. A panoramic-like image derived from CT, in contrast, follows a centerline fitted to the patient’s anatomy and has more uniform magnification and sharpness. In addition, the planning CT and the panorex are often acquired at different times and in different positions, introducing genuine differences in posture, bite, head orientation and dental status. Intensity-based registration is therefore poorly suited to this task, whereas the teeth themselves provide anatomical landmarks visible in both modalities.

In this work, we present Dosarex, a pipeline that annotates the routine panorex with tooth-level planning dose, produced end-to-end from the planning CT, structure set and dose without additional human intervention, using the teeth themselves as registration landmarks. In a large institutional cohort of patients with head and neck cancer, we evaluate the consistency of the transferred dose, its agreement with the CDON extraction thresholds, and its ability to identify teeth at risk compared with whole-jaw dose reporting.

5.2Methods

Interactive · Figures 5.1 – 5.7

From planning CT to a dose on every tooth

Dosarex runs these steps unattended for each patient. Select a step to read what it does and open its figure.

Overview. Dosarex takes two independently acquired inputs for each patient: the treatment planning CT with its structure set and planned dose distribution, and a panorex (Figure 5.1). The CT and dose volumes are first transformed into panorex-like projections by curved planar reformation along the mandible. Teeth are then segmented independently on the projected CT and on the panorex, and the centroid of each tooth is used as a landmark. The landmarks are matched between the two images and used to register the projected CT to the panorex, after which the projected dose is transferred to the panorex and the mean dose of each panorex tooth is computed.

Figure 5.1Overview of the Dosarex framework. The planning CT and dose are projected by curved planar reformation (CPR) into a panorex-like image. Teeth are segmented on the projected CT (nnU-Net) and on the panorex (SemiT-SAM), their centroids are matched and used for landmark-based registration, and the planning dose is transferred to each panorex tooth, yielding a tooth-level dose map on a routinely acquired image. Two inputs, the planning CT with its structure set and dose (top row) and the linked panorex (bottom row) are processed independently until registration, and no step requires manual contouring or operator input. The outputs are the planning dose warped onto the panorex (top right) and the per-tooth mean dose report shown to the clinician (bottom right).

Dataset. We retrospectively analyzed patients with head and neck cancer treated with radiotherapy at Princess Margaret Cancer Centre between 2005 and 2017, drawn from the RADCURE cohort Welch 2024. For each patient, the treatment planning CT, the structure set (RTSTRUCT) and the planned 3D dose distribution (RTDOSE) were exported from the treatment planning system, and the panorex images were retrieved and linked to the planning data through anonymized patient identifiers.

We identified 885 patients with a planning CT, an RTSTRUCT containing the mandible contour, an RTDOSE linked to the planning CT, and at least one linked panorex. Patients with several dose plans or repeat planning scans had more than one projection (938 projections in total); to give each patient equal weight, one projection per patient was selected before any processing, namely the first planning scan and, within it, the first dose plan.

Of the 885 eligible patients, 139 were excluded before analysis: 130 because fewer than two teeth were detected on the projected CT, 8 because fewer than two teeth were detected on the panorex, and 1 because the registration failed (Table 5.1). The patients without detectable teeth were predominantly edentulous, consistent with the absence of teeth on the corresponding panorex in most cases. Dosarex therefore processed 746 patients. After quality control, which excluded 34 patients (4.6%) with a registration error above 8mm, 712 patients, comprising 14,564 matched tooth pairs, were included in the dose analysis.

Table 5.1Study cohort and case flow. Counts are patients, with one projection per patient selected before processing. The 139 exclusions before processing comprise 130 patients with fewer than two teeth detected on the projected CT, 8 with fewer than two teeth detected on the panorex, and 1 registration failure. Quality control excluded a further 34 patients (4.6% of those processed).
Step Patients
Eligible: CT, RTSTRUCT, dose and panorex 885
Excluded: too few teeth to register (mostly edentulous) or registration failure −139
Processed by Dosarex 746
Excluded by quality control (registration error > 8mm) −34
Analyzed (14,564 matched tooth pairs) 712

Curved Planar Reformation. CPR was implemented headlessly in 3D Slicer Fedorov 2012, adapted from the CurvedPlanarReformat module of the PerkLab SlicerSandbox extension PerkLab 2026. The mandible contour from the planning RTSTRUCT was converted into a binary mask, and the medial curve (centerline) of the mandible was extracted from it. A straightening transform was computed along this curve and applied to both the CT and the dose volumes, yielding straightened volumes in which the dental arch is unfolded and the dose remains spatially aligned with the anatomy.

The straightened volumes were then projected to 2D by averaging along the bucco-lingual direction over a 30mm slab covering both jaws, yielding a panorex-like projected CT and a projected dose map with 1mm pixel spacing, in which each pixel represents the mean planning dose (Gy) through the slab.

Tooth Landmark Extraction. Tooth landmarks in each modality were obtained through a two-stage process. Each tooth is first segmented independently in the panorex and in the projected CT, after which the centroid of each segmented tooth is computed and used as its corresponding landmark. Tooth segmentation on the panorex was performed with SemiT-SAM Hao 2025. The network was initialized from its publicly released pretrained checkpoint and fine-tuned on the STS24 2D panoramic dataset Wang 2026, comprising 30 labeled and 2,350 unlabeled panorex images, following the semi-supervised teacher–student training protocol. The resulting student model was used to obtain per-tooth instance segmentation masks on all panorex images (Figure 5.2); detections with a confidence score below 0.3 were discarded. In addition to the instance masks, the model predicts one of 32 tooth classes for each detection, which was used to assign each panorex tooth to the maxilla or the mandible. Tooth segmentation on the projected CT was performed with nnU-Net Isensee 2021 in its 2D configuration, trained on 149 manually annotated projected CT images (119 for training, 30 for validation). Each image was labeled with three classes (background, tooth interior and tooth boundary), with the boundary class introduced to help the network separate closely spaced or touching teeth. The checkpoint with the best validation performance was applied to all projected CT images. Because this semantic output does not directly separate individual teeth, per-tooth instances were recovered from the predicted tooth-interior region by a post-processing step that separated teeth merged side by side (erosion and regrowth), split upper and lower teeth merged vertically (instances taller than 1.4 times the median tooth height), and cut remaining merges at minima of the tooth width profile; instances smaller than 20 pixels were discarded (Figure 5.3).

Figure 5.2Tooth landmark extraction on a representative panorex. (a) Per-tooth instance segmentation obtained using SemiT-SAM. (b) Centroid of each segmented tooth (red), extracted as its corresponding landmark. SemiT-SAM was fine-tuned on the STS24 panoramic dataset, and detections with a confidence score below 0.3 were discarded. Each detection also carries one of 32 tooth classes, which assigns the tooth to the maxilla or the mandible. Only the centroids are passed on to registration; the masks are reused later to compute the mean dose of each tooth.
Figure 5.3Tooth instance segmentation and corresponding centroid landmarks on a representative projected CT image. (a) Per-tooth instance segmentation obtained after post-processing, with each tooth shown in a distinct color. (b) Centroid of each segmented tooth (red), extracted as its corresponding landmark. The projected CT is the straightened planning CT averaged over a 30mm bucco-lingual slab at 1mm pixel spacing. A 2D nnU-Net predicts tooth interior and tooth boundary, and individual teeth are recovered from the interior class by separating teeth merged side by side or vertically and discarding instances smaller than 20 pixels.

Tooth Correspondence and Registration. Because of the geometric and appearance differences between the projected CT and the panorex, registration was based on corresponding tooth landmarks rather than image intensities. Correspondence between the projected CT and panorex landmarks was established with the Hungarian algorithm Kuhn 1955 (Figure 5.4). Since the two images differ substantially in scale and resolution, each landmark set was first normalized by subtracting its mean and dividing by its standard deviation, and the algorithm paired the landmarks to minimize the total Euclidean distance between the normalized point sets. When the number of teeth differed between the two images, the excess teeth were left unmatched. The mean normalized distance of the matched pairs was recorded as the matching cost.

Figure 5.4Tooth correspondence between the projected CT (left) and panorex (right) landmarks, established using the Hungarian algorithm. Corresponding teeth are connected by lines of matching color across the two modalities. Each landmark set was normalized before matching, so the pairing depends on the arrangement of teeth and not on image scale or resolution. When two images contain different numbers of teeth, the excess teeth are left unmatched.

For registration, the projected CT was first resampled to the pixel dimensions of the panorex, and a partial affine (similarity) transformation with four degrees of freedom, consisting of rotation, uniform scaling and translation, was estimated from the matched landmark pairs. This was preferred over a full affine model because it is more stable with few or nearly collinear landmarks and does not introduce non-physical shear. The transformation was estimated by least-median-of-squares regression Rousseeuw 1984, which keeps the estimate stable when a small number of correspondences produced by the Hungarian matching are incorrect. The estimated transformation was applied to warp the projected CT, and subsequently the projected dose map, into the panorex coordinate space (Figure 5.5). Cases where the estimator failed to return a valid transformation were recorded as registration failures.

Registration accuracy was quantified as the mean Euclidean distance between the transformed projected CT landmarks and their matched panorex landmarks. Because the projected CT has isotropic 1mm pixel spacing, the residuals were mapped back into projected CT coordinates through the inverse transformation and reported in millimeters. This in-sample error is computed on the same landmarks used to estimate the transformation, which is optimized to minimize these distances; it therefore underestimates the error at locations not used for fitting, as is well established for point-based registration, where the fiducial registration error is a poor predictor of the target registration error Fitzpatrick 1998. Because dose is sampled at every tooth, the clinically relevant quantity is the error at a tooth’s location rather than at the fitting landmarks. We therefore also computed a leave-one-landmark-out error, in which each matched tooth was predicted by a transformation estimated from the remaining teeth, approximating the target registration error at a location independent of the fit. This analysis was restricted to cases with at least four matched teeth, so that at least three landmarks remained for each estimate and the robust estimator retained redundancy beyond the minimum of two correspondences required by the four-degree-of-freedom transformation.

Figure 5.5Overlay of the warped projected CT on the panorex demonstrating the partial affine registration of the projected CT to the panorex using corresponding tooth landmarks. The transformation has four degrees of freedom (rotation, uniform scaling and translation) and was estimated by least-median-of-squares regression, which tolerates a small number of incorrect correspondences. A single global transformation aligns the dental arch as a whole and residual misalignment of individual teeth reflects the position-dependent magnification of the panorex, which this model does not capture.

Dose Mapping. The 3D planning dose was straightened and projected together with the CT by CPR, so the projected dose map is spatially aligned with the projected CT. This 2D dose map (in Gy) was then resampled to the panorex dimensions and warped into the panorex coordinate space with the partial affine transformation estimated during registration (Figure 5.6). For each tooth, the mean dose was computed within its mask dilated by approximately 1mm to include the tooth margin and surrounding alveolar bone, on both the projected CT (3 × 3 pixel kernel) and the panorex (kernel scaled to the panorex pixel size). The per-tooth doses of each matched tooth pair were then compared, yielding a per-tooth measure of dose consistency between the two images. The results are presented to the clinician as a report in which the tooth segmentations are overlaid on their corresponding images, with each tooth colored according to its mean dose (Figure 5.7).

Figure 5.6Radiation dose distribution on the projected CT and in the panorex coordinate space. (a) Projected dose distribution overlaid on the projected CT. (b) Dose distribution warped to the panorex using the estimated registration transformation and overlaid on the panorex. Each pixel of the projected dose is the mean planning dose through the 30mm slab. The warped dose covers only the field of view of the projected CT, so regions of the panorex outside it carry no dose estimate.
Figure 5.7Per-tooth dose on the projected CT (a) and the panorex (b). Each tooth is colored according to its mean dose on a common color scale and numbered according to its matched correspondence from the Hungarian assignment. The mean dose of each tooth is computed within its segmentation mask dilated by approximately 1mm, to include the tooth margin and adjacent alveolar bone. Panel (b) is the report presented to the clinician; panel (a) is the reference against which dose consistency is evaluated in Chapter 5.3.

Quality Control. Cases in which fewer than two teeth were detected on either image could not be registered and were excluded. Registration quality was then assessed from the registration error: cases with an error greater than one mean mesiodistal tooth width (8mm) were considered poorly registered and excluded from the dose analysis, since at this error the registered landmarks are, on average, displaced to the position of a neighboring tooth and the dose would be sampled from the wrong tooth Nelson 2019. Differences in tooth count between the two images and a low number of teeth were reported descriptively but were not used as exclusion criteria.

As a sensitivity analysis, quality control was also applied per tooth instead of per patient: each tooth was excluded if its own registration error, computed with the leave-one-landmark-out procedure (or in-sample for patients with fewer than four matched teeth), exceeded the mean mesiodistal width of its tooth type (5.0–11.0mm) Nelson 2019.

Statistical Analysis. For each matched tooth pair, the dose measured on the panorex was compared with the dose measured on the projected CT. Agreement between the two estimates was summarized by Bland–Altman analysis Bland 1986, reporting the mean difference (bias) and the 95% limits of agreement (bias ± 1.96 standard deviations of the differences), together with the mean and median absolute difference, the root-mean-square difference, the proportions of teeth agreeing within 1, 2 and 5 Gy, and the Pearson correlation coefficient. The primary analysis included all cases passing quality control.

Because overall agreement can mask systematic differences in the situations most relevant to dental decisions, the analysis was repeated in three sets of subgroups, each reflecting a known source of variation. First, the maxilla and the mandible (assigned from the panorex tooth class) were analyzed separately, because they differ in anatomy and in panoramic projection geometry, which may affect registration accuracy, and because the CDON guideline sets different extraction thresholds for each jaw. Second, teeth were grouped by CT dose (<20, 20–40, 40–60 and ≥60 Gy): a given misalignment produces a larger dose difference in steep dose gradients, which occur near the high-dose region, and extraction decisions are made at the upper end of the dose range, whereas the overall statistics are dominated by the more numerous teeth receiving intermediate doses. Third, cases with fewer than ten teeth on either image were compared with the remaining cases, since fewer landmarks constrain the registration less, and partially edentulous patients are common in this population.

To evaluate agreement at the level of the dental decision, each tooth was classified on both images as at or above versus below the CDON prophylactic-extraction threshold (≥70 Gy in the maxilla, ≥60 Gy in the mandible) Watson 2021. This analysis does not assess clinical outcomes; it tests whether using the panorex-derived dose instead of the projected CT dose would change the threshold-based recommendation for a tooth. Agreement between the two classifications was measured with percentage agreement, Cohen’s κ, sensitivity and specificity, using the projected CT as the reference. To reflect how the panorex dose could be used in practice, we also evaluated a review margin, in which teeth with a panorex dose within 2, 3, 5 or 7 Gy below the threshold were additionally flagged for review.

To quantify the value of tooth-level dose over current practice, we compared it with whole-jaw dose reporting. Because the jaw dose reported to dentists was not available for this cohort, it was approximated by assigning every tooth the mean, or alternatively the maximum, of the projected CT tooth doses in its jaw, and each tooth was classified against the CDON threshold using this single jaw value.

The association between registration error and the per-case mean absolute dose difference was assessed across all processed cases with Spearman’s rank correlation. Because teeth from the same patient are not independent, 95% confidence intervals for the agreement statistics were obtained by patient-level bootstrap (2,000 resamples of patients, percentile method).

In addition, agreement was summarized by tooth type (incisors, canines, premolars and molars) in each jaw and, in the supplementary material, by FDI tooth number, both derived from the panorex tooth class.

5.3Results

On the held-out set, projected CT tooth segmentation achieved a mean Dice coefficient of 0.75 for the tooth class and a tooth detection F1 score of 0.83 (precision 0.83, recall 0.84; IoU ≥ 0.5), with a median centroid error of 0.92mm for teeth matched between the annotation and the prediction. In the study cohort, a median of 23 [IQR 16–27] teeth was detected per projected CT and 24 [18–28] per panorex, of which a median of 23 [16–27] were matched (Table 5.2). Tooth counts were strongly correlated between the two images (r = 0.914); the panorex typically detected one more tooth than the projected CT (median difference 1 [IQR 0–2]), detecting more teeth in 53.9% of cases, the same number in 26.8% and fewer in 19.3%. The jaw assignment of matched pairs was consistent in 95.9% of teeth, indicating that the correspondence rarely paired teeth across jaws.

Table 5.2Overview of tooth detection, correspondence and registration results (n=746). Values are median [interquartile range, 25th–75th percentile across patients] unless stated otherwise. *723 patients with at least four matched teeth. The in-sample error is computed on the landmarks used to estimate the transformation; the leave-one-landmark-out error predicts each tooth from a transformation estimated on the remaining teeth and approximates the error at a location independent of the fit. The quality-control limit is one mean mesiodistal tooth width.
Measure Median [IQR] or value
Teeth per patient, projected CT 23 [16–27]
Teeth per patient, panorex 24 [18–28]
Matched teeth per patient 23 [16–27]
Panorex detected more / same / fewer teeth than CT 53.9% / 26.8% / 19.3%
Tooth count correlation (r) 0.914
Jaw agreement of matched pairs 95.9%
Registration error, in-sample (mm), median [IQR] 3.81 [2.80–5.33]
Registration error, leave-one-landmark-out (mm), median [IQR]* 4.45 [3.29–6.13]
Quality-control limit (mm) 8.00

The median registration error was 3.81mm [IQR 2.80–5.33] (mean 4.16 ± 2.18mm; Figure 5.8). Thirty-four patients (4.6%) exceeded the quality-control limit of 8mm and were excluded from the dose analysis. In the leave-one-landmark-out analysis (723 patients with at least four matched teeth), the median error was 4.45mm [IQR 3.29–6.13]; the median per-patient increase over the in-sample error was 11%, indicating that the transformation was not overfitted to the landmarks.

Figure 5.8Distribution of the mean landmark registration error between the projected CT and the panorex (n=746). The dashed line marks the quality-control limit of 8mm (one mean mesiodistal tooth width); the 34 patients above it were excluded from the dose analysis. The error is the in-sample mean Euclidean distance between the transformed projected CT landmarks and their matched panorex landmarks, in millimeters (mm) in projected CT coordinates (median 3.81mm, IQR 2.80–5.33mm). Each count on the vertical axis is one patient, since one projection per patient was analyzed.

Per-tooth dose derived from the panorex agreed closely with that measured on the projected CT (r = 0.978, 95% CI 0.975–0.981; Figure 5.9a). The bias was −0.26 Gy (95% CI −0.36 to −0.17) with 95% limits of agreement of −6.43 to +5.90 Gy (Figure 5.9b). The mean absolute difference was 1.88 Gy (95% CI 1.79–1.96) and the median 1.07 Gy [IQR 0.40–2.37], corresponding to 1.5% of a typical 70 Gy prescription; 47.8%, 70.0% and 91.9% of teeth agreed within 1, 2 and 5 Gy, respectively (Table 5.3).

Figure 5.9Per-tooth dose consistency between the projected CT and the panorex (14,564 teeth from 712 patients). (a) Panorex-derived versus projected CT dose; the dashed line indicates identity and shading indicates tooth density (log scale). (b) Bland–Altman plot of the difference (panorex − CT) against the mean of the two measurements, with the bias (solid line) and 95% limits of agreement (dashed lines).

Dose differences were strongly associated with registration quality: the per-patient mean absolute difference increased with registration error (Spearman ρ = 0.68, p < 0.001; Figure 5.10), and patients who failed quality control had a median absolute difference of 5.84 Gy, compared with 1.54 Gy for those who passed.

Figure 5.10Per-patient mean absolute dose difference against registration error for all 746 processed patients. Patients who failed quality control (orange diamonds) lie beyond the 8mm limit (dashed line). The median absolute dose difference was 5.84 Gy in patients who failed and 1.54 Gy in those who passed, which supports the registration error as the quality-control criterion.

Agreement was better in the mandible (bias +0.39 Gy, limits of agreement −4.28 to +5.05 Gy, mean absolute difference 1.55 Gy) than in the maxilla (bias −1.00 Gy, −8.25 to +6.25 Gy, 2.24 Gy). The difference increased with dose level, from a mean absolute difference of 1.07 Gy for teeth below 20 Gy to 2.68 Gy for teeth receiving 60 Gy or more, where the panorex systematically underestimated the dose (bias −2.24 Gy) (Figure 5.11, Table 5.3). By tooth type, the largest differences occurred in the maxillary molars (bias −2.43 Gy, mean absolute difference 3.59 Gy), whereas all mandibular tooth types had mean absolute differences below 1.8 Gy (Table 5.5). Patients with fewer than ten teeth showed no loss of agreement (mean absolute difference 1.29 Gy, compared with 1.90 Gy in patients with ten or more teeth).

Figure 5.11Per-tooth absolute dose difference by CT dose level and jaw. Boxes show the interquartile range with the median; whiskers extend to 1.5 × IQR, and outliers are not shown. Numbers below the boxes indicate the number of teeth. Teeth are from 712 patients passing quality control, grouped by their dose on the projected CT. The difference grows with dose level in the maxilla but not in the mandible, so the loss of agreement at 60 Gy or more is carried by maxillary teeth (n=257).
Table 5.3Per-tooth dose agreement between projected CT and panorex (cases passing quality control unless stated). Differences shown are panorex minus projected CT. LoA: 95% limits of agreement (bias ± 1.96 standard deviations); MAE: mean absolute difference; Median AE: median absolute difference; RMSE: root-mean-square difference. Dose-level rows group the teeth of cases passing quality control by their projected CT dose.
Subgroup Cases Teeth Mean CT dose (Gy) Bias (Gy) LoA lower (Gy) LoA upper (Gy) MAE (Gy) Median AE (Gy) RMSE (Gy) Pearson r <1Gy (%) <2Gy (%) <5Gy(%)
All processed cases 746 15,224 32.26 -0.34 -7.43 6.75 2.05 1.13 3.63 0.971 46.6 68.4 90.7
Passed QC 712 14,564 32.37 -0.26 -6.43 5.9 1.88 1.07 3.16 0.978 47.8 70.0 91.9
QC: maxilla 637 6,828 30.69 -1.0 -8.25 6.25 2.24 1.25 3.83 0.97 44.0 65.1 88.7
QC: mandible 709 7,736 33.85 0.39 -4.28 5.05 1.55 0.97 2.41 0.987 51.2 74.3 94.8
QC: >= 10 teeth 619 14,043 32.45 -0.26 -6.45 5.92 1.9 1.1 3.17 0.978 47.1 69.4 91.9
QC: < 10 teeth 93 521 30.15 -0.25 -5.77 5.27 1.29 0.5 2.82 0.986 67.6 85.4 94.4
CT dose < 20 Gy 241 2,534 9.54 0.0 -3.93 3.93 1.07 0.47 2.0 0.959 67.2 84.5 96.8
CT dose 20-40 Gy 608 8,006 30.5 0.12 -5.43 5.68 1.81 1.12 2.84 0.882 46.6 70.0 92.8
CT dose 40-60 Gy 500 3,370 47.43 -1.0 -8.64 6.64 2.47 1.5 4.02 0.78 37.0 60.2 87.5
CT dose >= 60 Gy 161 654 65.99 -2.24 -10.89 6.42 2.68 1.29 4.95 0.704 43.4 63.1 85.6

Of the 14,564 teeth, 459 (3.2%) were at or above the CDON threshold on the projected CT. Using the projected CT as reference (no clinical outcomes were assessed), the panorex classification agreed for 99.33% of teeth (κ = 0.883, 95% CI 0.852–0.911), most of which were below the threshold on both images. Of the 459 teeth at or above the threshold, the panorex identified 380 (sensitivity 0.828, 95% CI 0.777–0.875) and of 14,105 below it, it classified 14,087 (specificity 0.999) (Table 5.4). Disagreements were predominantly under-classifications: 79 teeth were at or above the threshold on the projected CT but not on the panorex, whereas 18 showed the reverse. Agreement was higher in the mandible (60 Gy; sensitivity 0.877, 95% CI 0.823–0.919; κ = 0.914) than in the maxilla (70 Gy; sensitivity 0.516, 95% CI 0.282–0.732; κ = 0.644), where only 62 teeth reached the threshold. For the 558 teeth whose CT dose lay within 5 Gy of the threshold, agreement was 83.0% (κ = 0.634). Of the 231 teeth at or above the threshold, the panorex identified 152 (sensitivity 0.658). All 79 missed teeth fell within this 5 Gy band. At the patient level, 139 of 712 patients had at least one tooth at or above the threshold, and the panorex gave the same patient-level classification for 97.3% of patients.

Flagging teeth whose panorex dose lay within 2 Gy below raised the number of 459 teeth identified from 380 to 427 (sensitivity 0.930) and 442 at 3 Gy (sensitivity 0.963). These margins flagged 3.4% and 3.9% of all teeth, respectively (Table 5.6). By comparison, whole-jaw dose reporting performed poorly in either direction: assigning each tooth the mean jaw dose identified only 211 of the 459 teeth at or above the threshold (46.0%), whereas assigning the maximum jaw dose identified all 459 but flagged 12.4% of all teeth, 4.6 times as many as the per-tooth panorex dose (2.7%).

Applying quality control per tooth instead of per patient retained 744 patients and 12,493 teeth, excluding 17.9% of teeth, mainly mandibular incisors (the narrowest teeth) and maxillary molars, while recovering 223 well-aligned teeth from 33 patients that had failed the per-patient limit. Agreement improved (bias −0.11 Gy; 95% limits of agreement −4.39 to +4.17 Gy; mean absolute difference 1.45 Gy), whereas threshold classification was essentially unchanged (agreement 99.42%, sensitivity 0.842, specificity 0.999).

Table 5.4Agreement between projected CT and panorex in classifying teeth at or above the CDON extraction threshold. Thresholds are 70 Gy in the maxilla and 60 Gy in the mandible. The last row is restricted to teeth whose projected CT dose lay within 5 Gy of the threshold. No clinical outcome is assessed: the table measures whether using the panorex dose would change a threshold-based recommendation with projected CT as reference.
Subgroup Teeth CT above threshold Both above (TP) Both below (TN) Pano above only (FP) Pano below only (FN) Agreement (%) Cohen kappa Sensitivity Specificity
All (70 Gy maxilla / 60 Gy mandible) 14,564 459 380 14,087 18 79 99.33% 0.883 0.828 0.999
Maxilla (70 Gy) 6,828 62 32 6,761 5 30 99.49% 0.644 0.516 0.999
Mandible (60 Gy) 7,736 397 348 7,326 13 49 99.2% 0.914 0.877 0.998
<5 Gy of threshold 558 231 152 311 16 79 82.97% 0.634 0.658 0.951
Table 5.5Agreement by jaw and tooth type. Per-tooth dose agreement and threshold classification for the 14,564 teeth of the 712 patients passing quality control, with tooth type derived from the panorex tooth class. Bias and MAE are defined as in Table 5.3. Threshold agreement and sensitivity use the CDON threshold of each jaw, with the projected CT as reference. Specificity was 0.997–1.000 for all tooth types and is therefore not shown. Sensitivity in the maxilla is based on 12–20 teeth at or above the threshold per tooth type and should be interpreted with caution.
Jaw Tooth type Teeth Mean CT dose (Gy) Bias (Gy) MAE (Gy) Within
2Gy (%)
At/above threshold on CT Threshold agreement (%) Sensitivity
Maxilla Incisors 2,040 25.5 -0.24 1.28 82.3 14 99.6% 0.50
Canines 1,115 28.2 -0.52 2.03 64.1 12 99.5% 0.50
Premolars 1,773 31.6 -0.65 2.04 65.5 20 99.4% 0.50
Molars 1,900 36.9 -2.43 3.59 46.9 16 99.5% 0.56
Mandible Incisors 2,188 28.7 0.75 1.4 77.2 64 99.6% 0.91
Canines 1,329 30.9 1.04 1.63 72.4 38 99.3% 0.84
Premolars 2,234 34.3 0.69 1.49 76.3 100 99.3% 0.88
Molars 1,985 41.0 -0.79 1.74 70.0 195 98.5% 0.87
Table 5.6Identifying teeth at or above the CDON threshold: per-tooth panorex dose vs whole-jaw reporting (projected CT as reference). Whole-jaw reporting was approximated by assigning every tooth the mean/maximum projected CT tooth dose in its jaw. A review margin additionally flags teeth whose panorex dose lies within the stated margin below the threshold. Teeth flagged is the percentage of all 14,564 teeth classified at or above the threshold or flagged for review. Missed teeth are those at or above the threshold on the projected CT (n=459) that were not flagged.
Approach Sensitivity Specificity Teeth flagged (%) Missed teeth
Whole-jaw mean dose 0.46 0.997 1.7% 248
Whole-jaw maximum dose 1.00 0.904 12.4% 0
Dosarex (per-tooth dose) 0.828 0.999 2.7% 79
Dosarex, 2 Gy review margin 0.930 0.995 3.4% 32
Dosarex, 3 Gy review margin 0.963 0.991 3.9% 17
Dosarex, 5 Gy review margin 0.976 0.983 4.8% 11

From Table 5.6

One number per jaw cannot serve a per-tooth threshold

459 of 14,564 teeth were at or above the CDON extraction threshold on the planning CT. Each approach is scored on how many of them it catches and how many teeth it flags overall.

Projected CT dose is the reference. Whole-jaw values were approximated from projected CT tooth doses because the jaw dose reported in clinic was not available. No clinical outcomes were assessed.

5.4Chapter discussion

Dosarex automatically annotates routine panorex with tooth-level planning dose, without manual delineation, with close agreement to the projected planning dose and high overall agreement on CDON extraction-threshold classification across a large institutional cohort. By overlaying tooth-level dose on a format dentists already use, Dosarex can support pre-radiotherapy dental decision-making. In 712 patients and 14,564 teeth, the dose transferred to the panorex reproduced the dose measured on the projected CT with a median difference of about 1 Gy and negligible overall bias, and the two images agreed on whether a tooth reached the CDON extraction threshold for 99.3% of all teeth. Of the 459 teeth at or above the threshold, the Dosarex pipeline can identify 380 (sensitivity 0.83) based on the panorex, and up to 442 (sensitivity 0.963) by increasing the review margin. The leave-one-landmark-out error was close to the in-sample error, indicating that the registration generalizes beyond the landmarks used to estimate it. The pipeline ran unattended from the planning DICOM study to the per-tooth report for 746 of the 885 eligible patients, 138 of the 139 it could not process had fewer than two teeth detected on one of the two images, and most of these were edentulous.

Registration was the main source of disagreement. Dose differences increased steadily with registration error, and the few cases that failed quality control accounted for the largest discrepancies. This is consistent with the geometric differences between the two modalities: the non-uniform, angle-dependent magnification of the panorex cannot be fully captured by a single partial affine transformation. Non-rigid registration, or explicit modeling of the panoramic focal trough, is therefore the most direct route to further improving accuracy.

Per-tooth quality control further narrowed the limits of agreement to about ±4 Gy, indicating that much of the remaining disagreement comes from a minority of individually misaligned teeth. Because the per-tooth error is available without any dose reference, it could be used to flag teeth with uncertain dose in the clinical report rather than excluding the whole patient.

The panorex tended to underestimate dose to the most highly irradiated teeth, particularly in the maxilla. In steep dose gradients, small misalignments shift the tooth mask partly into lower-dose regions, pulling the per-tooth mean downward. Clinically, this is the less safe type of error, since a tooth at or above the threshold may be reported as below it; sensitivity was 0.83 overall and 0.52 in the maxilla, where few teeth reached 70 Gy. Until registration is further improved, teeth whose panorex dose lies within a margin of the threshold (for example 3 Gy, which recovered 96% of teeth at or above the threshold) could be flagged for review rather than classified automatically.

The limits of agreement observed here (approximately ±6 Gy) are wider than the interobserver limits reported for RADMAP (±2.88 Gy) van Dijk 2025. The two quantities are not directly comparable, however: RADMAP’s limits describe agreement between observers on the same image, whereas ours describe agreement between two independently acquired images of different modalities.

In clinical terms, the median difference of 1.07 Gy corresponds to 1.5% of a typical 70 Gy prescription, and the limits of agreement (about ±6 Gy) are half the 12.4 Gy difference in tooth-region dose that separated ORN-affected from unaffected sites van Dijk 2025. The differences that matter for decisions occur near the extraction thresholds, where a 3 Gy review margin recovered 96% of teeth at or above the threshold while flagging fewer than 4% of teeth for review.

The comparison with current practice bears most directly on the dental decision. A single whole-jaw value cannot serve a tooth-level threshold: the mean jaw dose identified 46% of the teeth at or above the threshold, and the maximum jaw dose identified all of them only by flagging 12.4% of all teeth, 4.6 times as many as the per-tooth dose. Per-tooth dose with a 3 Gy review margin identified 96% of these teeth while flagging 3.9%. The whole-jaw values were approximated from projected CT tooth doses, because the jaw dose reported to dentists was not available for this cohort, so the comparison should be repeated against the dose reported in clinic.

5.4.1Limitations and next steps

Our study has some limitations. The comparison between projected CT and panorex measures the consistency of dose transfer rather than accuracy against the true 3D dose to each tooth, and the dose projection averages over a 30mm bucco-lingual slab. In addition, panoramic acquisition dates were not available, so changes in dental status between the panorex and the planning CT could not be accounted for. The cohort comes from a single institution, and the projected CT segmentation model was trained on 149 images from the same source, so performance on other scanners, panoramic units and patient populations is untested. Finally, the pipeline does not process every sample flawlessly, 34 of 885 patients (3.8%) failed quality control.

This study can be expanded to validate Dosarex against the true 3D dose to each tooth, by comparing its per-tooth values with the mean dose within manually contoured tooth volumes on the planning CT for a subset of patients and validated externally on data from other institutions. Beyond technical validation, combining per-tooth dose with clinical features to model per-tooth ORN risk would establish whether the reported dose can reliably inform extraction decisions. The existing per-tooth dose-ORN analysis rests on 23 patients and 21 affected tooth regions van Dijk 2025. Since Dosarex is fully automated, it can be applied retrospectively to entire institutional cohorts, enabling per-tooth dose–outcome analyses at a scale not previously feasible, including graded ORN severity rather than ORN alone: the ClinRad classification grades the vertical extent of necrosis and the presence of exposed bone or fistula Watson 2024, so models can be trained on graded outcomes.

Furthermore, if per-tooth dose is available automatically at planning time, it can become an input to plan optimization rather than only a reporting output. Current dose constraints for the jaw are defined at the level of the whole mandible or jaw; mandibular NTCP model constrains 30% of the mandible to 35 Gy or 42 Gy depending on pre-radiotherapy extraction status van Dijk 2021, and the ISOO-MASCC-ASCO guideline advises reducing the mean dose to the jaw and the volume of bone above 50 Gy wherever possible Peterson 2024. A per-tooth objective would allow dose to be traded between tooth regions according to which teeth the dentist intends to retain. Together, these directions position Dosarex as a foundation for large-scale per-tooth dose–outcome studies and tooth-aware radiotherapy planning.

Chapter 6Conclusion10 min read

How to adopt machine learning models into the clinic

The distance between a raw, clinical dataset and a complex clinical decision is usually described as a modelling problem. This thesis measured that distance differently.

6.1Summary

This thesis contributed, in order:

  • RADCURE: The largest public head and neck CT collection (n=3,346)

  • Med-ImageTools: An open-source Python package for medical imaging dataset processing validated at scale

  • Four evaluation studies investigating what imaging models actually learn:

    • RADCURE-challenge: institution-wide challenge to predict survival and personalized prognosis

    • Deep-CR-MTLR: a novel competing-risks survival modelling method to investigate cause-specific survival

    • READII-2-ROQC: a nine-condition negative-control framework

    • SCARF: a quantitative evaluation of segmentation models and blinded clinical acceptability benchmark

  • Patient-level iENE model, externally validated, with comprehensive model evaluations, including varying clinical operating thresholds

  • Dosarex, a fully automated pipeline that reports radiation dose per tooth on routine panoramic radiographs, without any manual contouring or operator intervention.

  • Miscellaneous methods works include: FastCPH, FAIR-HNC, and jarvAIs.

The evidence supports the four hypotheses of Chapter 1.12 to differing degrees. The curation of the largest head and neck cancer imaging dataset and open-source software package for automated preprocessing supports the original hypothesis, as shown by the time-savings and large adoption of the RADCURE dataset by other studies. In Chapter 3, the prognostic performance was largely attributable to tumour volume or extratumoural context (Ch.3.2.3 and Ch.3.4.3), and rankings by geometric performance and by clinical acceptability diverged (Ch.3.5.4), supporting the hypothesis. The Chapter 4 hypothesis is partially supported since the iENE model outperformed the clinical baseline, while its margin over the volume baseline was not distinguishable from zero in paired comparison (Table 4.2, Supp.Table 4). Stratification of distant control at τ=0.50 was comparable to that of the radiologist in both cohorts (Table 4.5). For distant failure within 2 years, the model at τ=0.50 gave a net benefit similar to the radiologist’s determination in both cohorts (Table 4.8). Dosarex meets the Chapter 5 hypothesis halfway, the pipeline having been implemented and technically validated by comparing dose consistencies between the panorex and projected CT. However, the evaluation of accuracy against 3D dose and whether it helps dentists make better informed decisions have not been tested yet.

6.2Reproducibility as a scientific result

Reproducibility in this thesis is not a stated virtue but an evidenced property. Med-ImageTools is the processing engine for all of the projects built on the RADCURE dataset: SCARF's CONSORT-AI accounting credits Med-ImageTools data curation with 240 of 450 developer-hours saved; READII-2-ROQC builds its provenance layer on the same tooling. And the iENE model ships as a fully reproducible study, from public training data, released labels and split, weights, and locked environment—contributions equal in weight to its AUROC, allowing an external group to scrutinize the held-out result and test on their own datasets without our involvement.

jarvAIs is an open-source Python package for reproducible machine learning research on oncology data. It packages every decision along the development process into reproducible, configurable settings, including training data auditing, model hyperparameter selection, feature reduction and selection choices, validation splits, bias detection, model interpretability modules, and post-hoc fairness audits. We compared jarvAIs to AIM2REDUCE-ED, a hand-built model for 30-day emergency department visits during systemic therapy at Princess Margaret, currently in silent deployment Grant 2023Kabir 2024. The automated jarvAIs pipeline matched it on the held-out set (AUROC 0.70 vs 0.69, AUPRC 0.23 vs 0.20), trailed it modestly in the prospective cohort (0.67 vs 0.69, AUPRC 0.11 vs 0.16), and identified the treatment-regimen subgroups a manual bias analysis had flagged, in under thirty minutes of development time Siraj 2025. Reproducibility does not have to be expensive if the infrastructure and tooling are developed intentionally and used as the default path, paving a translational highway for machine learning models into the clinic.

6.3Evaluating cancer imaging models

The RADCURE challenge (Ch.3.2) measured the tumour volume confounder in the wild. Engineered radiomics predictions correlated with volume at ρ=0.79 to 0.85, and the winning model used EMR features plus volume explicitly. The same pattern appeared in our multi-institutional federated study, where a Cox model on clinical variables (n=1,492) reached a C-index of 0.62 to 0.73 across nodes, a radiomics-only model (n=1,321) reached 0.61 to 0.68, and the mixed model reached 0.60 to 0.72, with no improvement over the clinical model alone Gouthamchand 2024. READII-2-ROQC (Ch.3.4) turned the observation into a controlled test. The Aerts signature survived nine negative controls unchanged and never separated from the volume-only baseline, and the foundation model's features were shown to derive from the background rather than the tumour. SCARF (Ch.3.5) demonstrated that geometric rankings and clinical acceptability rankings diverge.

The common lesson is that AUROC, DSC and C-index are proxies of the underlying metric we’re actually interested in. Each is chosen because it is tractable, not because it is the quantity a clinician cares about, and we believe a proxy's job is to predict how well a model serves a specific decision. SCARF demonstrates that a proxy can do that job measurably poorly at the extremes, and the RADCURE-challenge and READII results show that a strong number can describe tumour size or surrounding context rather than the tumour itself. None of this means imaging is uninformative. Model 9 from the RADCURE-challenge reached AUROC 0.766 at ρ=0.22, and READII identified a class of features that responds to structured perturbation while remaining independent of volume. Imaging signal is learnable, but it must be demonstrated by construction. Volume correlation analysis, negative controls, ablation evidence, and superiority over a volume baseline are what can separate a model that has learned valuable features beyond tumour volume, and we believe they should be as routine as cross-validation.

6.4Models must be built around a decision

The iENE model in Chapter 4 was designed against the findings above rather than evaluated against them after the fact. Its correlation with the largest nodal volume was characterized directly (Pearson r = 0.335, Spearman ρ = 0.587), it confidently rejected several cases with very large GTVn, and it scored above the volume baseline on both AUROC and AUPRC, although the paired differences were not distinguishable from zero. The READII-2-ROQC negative controls tie the model’s output to the node and its surroundings and not to the interior of the primary tumour, but it does not fully separate the model from nodal size. We used ACS convolutions on the full neck volume rather than on segmented nodes, removing the dependency on a lymph node contour—an auto-segmentation step that, as SCARF showed even for well-defined OARs, cannot be assumed clinically acceptable on the strength of geometric metrics. What the model could not remove is the variability in the radiologist labels it was trained on, but we instead leveraged the clinician’s labels to compare against the model’s predictions to characterize its prognostic performance. We evaluated the effect of varying decision thresholds, acknowledging that one model serves two decisions with different costs of error, and treated τ as a clinical dial rather than a nuisance parameter.

Dosarex is the clearest case in this thesis of a design driven by the decision rather than by the data. The decision is whether to extract a specific tooth before radiotherapy, against external thresholds of 70 Gy in the maxilla and 60 Gy in the mandible Watson 2021, yet dose is conventionally reported for the whole jaw, and whole-mandible dose does not reliably predict ORN where per-tooth dose does van Dijk 2025. Dosarex reports the dose estimate on the panorex dentists routinely read, at the level of the individual tooth on which the extraction decision can be made, without requiring manual delineation. Across 14,564 teeth in 712 patients, it agreed with the projected planning dose to a median absolute difference of 1.07 Gy and identified 380 of the 459 teeth at or above the CDON threshold classification (83%) while flagging 2.7% of all teeth, up to 442 teeth by flagging 3.9% of all teeth. On the contrary, the whole-jaw mean found 211 (46%) and the whole-jaw maximum found all 459 only by flagging 12.4% of all teeth. While these results establish consistent dose transfer, there is no evidence of accuracy against the 3D dose or clinical benefit to patients.

6.5Future directions

Our studies can continue into several different directions:

Federated learning addresses both the training-scale limit and the single-institution limit without relocating sensitive patient data. Gouthamchand and colleagues federated five head and neck cohorts that shared no schema at their point of origin, comprising HN1, HNSCC, HEAD-NECK, a private MAASTRO dataset, and the Princess Margaret OPC-Radiomics collection, which our group prepared and hosted as the Canadian node. Data content was decoupled from schema into RDF, annotated with the Radiation Oncology Ontology and the NCI Thesaurus as a metadata layer, and read back through a single semantic query. Federated Cox models were then trained and validated across the network by leave-one-dataset-out internal-external validation under the Personal Health Train paradigm, with no patient-level data leaving any station Gouthamchand 2024. The infrastructure to federate both conventional and deep learning models already exists, and international collaborations have been successfully demonstrated Choudhury 2025. Chapter 4 showed that architectural gains from attention or added capacity are constrained by a training set of 752 patients, and that a single external cohort with a different case mix reduced AUROC from 0.913 to 0.671. A federated iENE study across the institutions that already contribute to these networks is the most direct way to test whether the model's performance is limited by data or by the problem. Med-ImageTools was designed with this use in mind, since each participating node can run the same processing pipelines without requiring any manual curation and produce identically structured ML-ready data.

Better labels, better decisions. iENE is a radiologist determination with documented interobserver variability Hoebers 2022Sahin 2025. Every model trained on it inherits that variability as a ceiling, and the single-reader labels used in our study are the greatest limitation Kim 2026. Hoebers and colleagues showed that concordance is trainable, with inter-institutional kappa rising from 0.40 to 0.65 once operating definitions were consolidated Hoebers 2022. The Head and Neck Cancer International Group consensus criteria published in 2024 replaced an informal reading of iENE with a four-tier classification and an explicit rule for equivocal findings, and all seventeen surveyed experts said they would adopt synoptic reporting in routine practice Henson 2024. This means that grade-level, multi-reader labels can be generated prospectively as part of routine reporting rather than as a separate research exercise. A model trained on HNCIG synoptic reports would produce outputs that map directly onto the 9th edition staging variable, distinguishing perinodal fat extension from conglomerate nodes from invasion of adjacent structures and would be interpretable against criteria that carry known diagnostic confidence. This is the change most likely to move the iENE model from a research result to a clinical instrument, and it depends more on reporting practice than on modelling.

Beyond oropharynx. The iENE model was trained on a cohort only with oropharyngeal cancer patients. Treatment escalation driven by ENE is also common in oral cavity and laryngeal disease, and the 9th edition now uses unequivocal iENE as a criterion for cN3 in non-viral head and neck cancer Brierley 2026, so the same prediction target applies across subsites. Extending our study to other subsites will test the model’s generalizability and reveal whether to expand the training set to non-OPC cohorts with iENE labels.

Beyond CT. The iENE model is restricted to CT despite the superior soft-tissue contrast of MRI, and the Maastro validation showed that labels made on MRI were predicted nearly as well as labels made on CT. This suggests the planning CT carries more of the relevant signal than is usually assumed, but a direct comparison with MRI input, or a multimodal model where both are available, has not yet been done in existing literature, according to our best knowledge.

From dose consistency to dose–outcome. Dosarex has so far been validated for consistency against the projected CT. The first step of validation is comparing Dosarex’s output against the mean dose in manually contoured tooth volumes on the planning CT. A clinical validation could be comparing per-tooth dose–outcome modelling against graded ORN severity Watson 2024, where the existing evidence rests on 23 patients van Dijk 2025. Per-tooth dose available at planning time could then become a planning objective. Lastly, integration into the clinic is already underway, with dental practitioners eager for adoption to make more granular decisions on which teeth to preserve.

Deployment is an art. Every model in this thesis was built to be run by someone else. The remaining step is to make running them routine rather than possible. SCARF is already embedded in MIRA, the institutional platform that extracted RADCURE, and the jarvAIs API service was built to serve models into the same infrastructure. Serving the iENE model and the Dosarex pipeline through MIRA, with Med-ImageTools handling DICOM input and containerizing our software with fully reproducible environments, would close the translational loop. This integration would blaze the trail for the next area of research of implementation science, investigating how AI systems augment and impact clinical decision making.

6.6Concluding remarks

The distance between a raw, clinical dataset and a complex clinical decision is usually described as a modelling problem. This thesis measured that distance differently. First, curation is a scientific step and should be treated as one. The choices made while converting DICOM into model inputs shape every downstream result, and Med-ImageTools exists so that those choices are written down, versioned, and repeatable. Second, a performance metric is a claim about a model that must itself be tested. The volume confounder, the negative-control results, and the gap between geometric accuracy and clinical acceptability all show that a strong number can describe something other than what it appears to describe. Third, a model earns clinical relevance by being aimed at a decision. Our iENE model’s output lives on the scale a radiologist uses and a staging system now requires, and Dosarex reports dose at the level a dentist acts on. None of this replaces the clinician—the iENE model enriches a review queue, Dosarex informs a chairside decision, and both leave the critical judgment where it belongs. What our studies offer is a way of building these tools so that the judgment they support is better informed, and the evidence behind them can be checked by anyone who wants to. An imaging AI model is trustworthy when its data pipeline is transparent and reproducible, its signal is thoroughly characterized, and its output is aimed at a real clinical decision to assist responsibly.

Statement of contributions

Publications

This thesis is manuscript-based. The chapters incorporate most of the following works I contributed to during the duration of my PhD.

I hold first / co-first authorship on five public works (Med-ImageTools, RADCURE, RADCURE-challenge, Deep-CR-MTLR, and iENE), led the software development of two open-source Python packages: Med-ImageTools and jarvAIs, and first authorship on the iENE manuscript under review at Lancet Digital Health and co-first authorship of the Dosarex manuscript in preparation.

Ch. 2Co-first author

RADCURE

Medical Physics 2024;51(4):3101–3109

  • Methodology
  • Software
  • Validation
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing
Ch. 2First author

Med-ImageTools

F1000Research 2025;12:118 (v3)

  • Conceptualization
  • Methodology
  • Software
  • Validation
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Original Draft
  • Visualization
Ch. 3Co-first author

RADCURE-challenge

Cancer Res Comms 2023;3(6):1140–1151

  • Methodology
  • Software
  • Validation
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing
Ch. 3Co-first author

Deep-CR-MTLR

AAAI Spring Symposium 2021

  • Conceptualization
  • Methodology
  • Software
  • Validation
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Original Draft
  • Visualization
Ch. 33rd author

FastCPH

NeurIPS 2022 Workshop HITY, TS4H

  • Methodology
  • Software
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing
Ch. 32nd author2nd author

READII-2-ROQC

ICHNO 2024, ICCR 2024Cancer Research, in submission

  • Conceptualization
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing
Ch. 37th author

SCARF

phiRO 2026;39:101015

  • Conceptualization
  • Methodology
  • Software
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing
Ch. 4First authorFirst author

iENE

ICHNO 2024, Best Paper AwardJournal of Clinical Oncology, under review

  • Conceptualization
  • Methodology
  • Software
  • Validation
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Original Draft
  • Visualization
Ch. 5Co-first author

Dosarex

In preparation

  • Conceptualization
  • Methodology
  • Software
  • Validation
  • Formal analysis
  • Investigation
  • Resources
  • Data Curation
  • Writing – Original Draft
  • Visualization
Ch. 63rd author

jarvAIs

Clinical Cancer Research (2025) 31; B001

  • Supervision
  • Conceptualization
  • Methodology
  • Software
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing
Ch. 66th author

FAIR-HNC

BJR Artificial Intelligence 1.1 (2024)

  • Methodology
  • Software
  • Investigation
  • Resources
  • Data Curation
  • Writing – Review & Editing

150 works cited

References

Our studies

  1. 1Kim 2025Kim S, Kazmierski M, Qu K, Peoples J, Nakano M, Ramanathan V, Marsilla J, Welch M, Simpson A, Haibe-Kains B. Med-ImageTools: An open-source Python package for robust data processing pipelines and curating medical imaging data. F1000Research 2025, 12:118.
  2. 2Welch 2024Welch ML*, Kim S*, Hope AJ, Huang SH, Lu Z, Marsilla J, Kazmierski M, Rey-McIntyre K, Patel T, O'Sullivan B, Waldron J, Bratman S, Haibe-Kains B, Tadic T; Princess Margaret Head and Neck Site Group. RADCURE: An open-source head and neck cancer CT dataset for clinical radiation therapy insights. Med Phys 2024;51:3101–3109.
  3. 3Kazmierski 2023Kazmierski M*, Welch M*, Kim S*, McIntosh C, Rey-McIntyre K, Huang SH, Patel T, Tadic T, Milosevic M, Liu F-F, Ryczkowski A, Kazmierska J, Ye Z, Plana D, Aerts HJWL, Kann BH, Bratman SV, Hope AJ, Haibe-Kains B. Multi-institutional Prognostic Modeling in Head and Neck Cancer: Evaluating Impact and Generalizability of Deep Learning and Radiomics. Cancer Res Commun 2023;3(6):1140–1151.
  4. 4Kim 2021Kim S*, Kazmierski M*, Haibe-Kains B. Deep-CR-MTLR: a Multi-Modal Approach for Cancer Survival Prediction with Competing Risks. Proceedings of the AAAI Spring Symposium on Survival Prediction — Algorithms, Challenges and Applications. PMLR 2021;146:223–231.
  5. 5Yang 2022Yang X, Abraham L, Kim S, Smirnov P, Ruan F, Haibe-Kains B, Tibshirani R. FastCPH: Efficient Survival Analysis for Neural Networks. NeurIPS 2022 Workshop HITY, TS4H.
  6. 6Scott 2026Scott KL, Kim S, Siraj J, Geady C, Boccalon M, Welch M, Alim M, Hope AJ, Haibe-Kains B. Negative controls reveal volume-driven confounding in radiomics and imaging foundation model features. arXiv:2607.28423v1 [cs.CV], 30 Jul 2026.
  7. 7Marsilla 2026Marsilla J, Welch ML, Siraj J, McElcheran C, Kim JW, Tkachuck D, Kim S, Cho J, Hahn E, Hosni A, Jacinto JC, Kazmierski M, Rey-McIntyre K, Huang SH, Patel T, Tadic T, Bratman S, Hope A, Haibe-Kains B. Auto-segmentation of organs-of-interest clinical acceptability & reproducibility framework in head and neck cancer. Phys Imaging Radiat Oncol 2026;39:101015.
  8. 8Kim 2026Kim S, Huang SH, Bartlett E, Yu E, Hoebers F, Postma AA, Palm WM, McIntosh C, Bratman S, Waldron J, O'Sullivan B, Haibe-Kains B, Hope A. Patient-level prediction of imaging extranodal extension from radiotherapy planning CT in oropharyngeal carcinoma using deep learning. International Congress on Innovative Approaches in Head and Neck Oncology. 2024. Submitted to Journal of Clinical Oncology.
  9. 9Siraj 2025Siraj J, Kabir M, Kim S, He JC, Yuan B, Uy W, Patel T, Grant B, Narine S, Krzyzanowska M, Truong T, Liu G, McElcheran C, Grant R, Welch M. Jarvais: A modular framework to standardize machine learning workflows. Clin Cancer Res 2025;31(13_Suppl):B001.

Other studies

  1. 10Bray 2018Bray F, Ferlay J, Soerjomataram I, Siegel RL, Torre LA, Jemal A. Global Cancer Statistics 2018: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. CA Cancer J Clin 2018;68:394–424.
  2. 11Chow 2020Chow LQM. Head and Neck Cancer. N Engl J Med 2020;382(1):60–72.
  3. 12Lydiatt 2017Lydiatt WM, Patel SG, O'Sullivan B, Brandwein MS, Ridge JA, Migliacci JC, Loomis AM, Shah JP. Head and Neck Cancers—Major Changes in the American Joint Committee on Cancer Eighth Edition Cancer Staging Manual. CA Cancer J Clin 2017;67:122–137.
  4. 13O'Sullivan 2013O'Sullivan B, Huang SH, Siu LL, et al. Deintensification Candidate Subgroups in Human Papillomavirus–Related Oropharyngeal Cancer According to Minimal Risk of Distant Metastasis. J Clin Oncol 2013;31:543–550.
  5. 14Schlichting 2019Schlichting JA, Pagedar NA, Chioreso C, Lynch CF, Charlton ME. Treatment trends in head and neck cancer: Surveillance, Epidemiology, and End Results (SEER) Patterns of Care analysis. Cancer Causes Control. 2019 Jul;30(7):721-732.
  6. 15Zheng 2025Zheng D, Zhang S, Bidadi B, Lerman N, Song Y, Song R, Li J, Zhu A, Tang Y, Signorovitch J, Merchant S, Hanna GJ. Real-world treatment patterns and clinical outcomes among elderly patients with locoregionally advanced head and neck squamous cell carcinoma in the United States. Front Oncol 2025;15:1606990.
  7. 16Benchetrit 2021Benchetrit L, Torabi SJ, Givi B, Haughey B, Judson BL. Prognostic Significance of Extranodal Extension in HPV-Mediated Oropharyngeal Carcinoma: A Systematic Review and Meta-analysis. Otolaryngol Head Neck Surg 2021;164(4):720–732.
  8. 17Sahin 2025Sahin O, Kamel S, Wahid KA, Dede C, Taku N, He R, Naser MA, Sharafi CS, Mäkitie A, Kann BH, Kaski K. International multispecialty expert physician preoperative identification of extranodal extension in patients with oropharyngeal cancer using computed tomography: Prospective blinded human inter‐observer performance evaluation. Cancer. 2025 Apr 1;131(7):e35815.
  9. 18Huang 2025Huang SH, Su J, Koyfman SA, et al. A Proposal for HPV-Associated Oropharyngeal Carcinoma in the Ninth Edition Clinical TNM Classification. JAMA Otolaryngol Head Neck Surg 2025;151(7):655–664.
  10. 19Brierley 2026Brierley JD, Van Eycken LJ, Giuliani ME, Rous BA, Huang SH, Asamura H, Gospodarowicz MK, Lee AW, O'Sullivan B. The 9th Edition of the UICC TNM Classification of Malignant Tumours: Updates and Rationale for Change. Int J Cancer 2026;159:1588–1601.
  11. 20Ferris 2022Ferris RL, Flamand Y, Weinstein GS, et al. Phase II Randomized Trial of Transoral Surgery and Low-Dose Intensity Modulated Radiation Therapy in Resectable p16+ Locally Advanced Oropharynx Cancer: An ECOG-ACRIN Cancer Research Group Trial (E3311). J Clin Oncol 2022;40:138–149.
  12. 21Yang 2021Yang J, Huang X, He Y, Xu J, Yang C, Xu G, Ni B. Reinventing 2D Convolutions for 3D Images. IEEE Journal of Biomedical and Health Informatics, 2021; 25(8):3009-18.
  13. 22Welch 2019Welch ML, McIntosh C, Haibe-Kains B, et al. Vulnerabilities of radiomic signature development: The need for safeguards. Radiother Oncol 2019;130:2–9.
  14. 23Traverso 2020Traverso A, Kazmierski M, Zhovannik I, et al. Machine learning helps identifying volume-confounding effects in radiomics. Phys Med 2020;71:24–30.
  15. 24Maier-Hein 2024Maier-Hein L, Reinke A, Godau P, et al. Metrics reloaded: recommendations for image analysis validation. Nat Methods 2024;21:195–212.
  16. 25Reinke 2024Reinke A, Tizabi MD, Baumgartner M, et al. Understanding metric-related pitfalls in image analysis validation. Nat Methods 2024;21:182–194.
  17. 26Kann 2018Kann BH, Aneja S, Loganadane GV, et al. Pretreatment Identification of Head and Neck Cancer Nodal Metastasis and Extranodal Extension Using Deep Learning Neural Networks. Sci Rep 2018;8:14036.
  18. 27Kann 2020Kann BH, Hicks DF, Payabvash S, et al. Multi-Institutional Validation of Deep Learning for Pretreatment Identification of Extranodal Extension in Head and Neck Squamous Cell Carcinoma. J Clin Oncol 2020;38(12):1304–1311.
  19. 28Ye 2026Ye Z, Mojahed-Yazdi R, Zapaishchykova A, et al. Automated Lymph Node and Extranodal Extension Assessment Improves Risk Stratification in Oropharyngeal Carcinoma. J Clin Oncol 2026;44(5):386–399.
  20. 29Dayan 2026Dayan GS, Hénique G, Bahig H, et al. Artificial Intelligence Model for Imaging-Based Extranodal Extension Detection and Outcome Prediction in Human Papillomavirus-Positive Oropharyngeal Cancer. JAMA Otolaryngol Head Neck Surg 2026;152(1):7–17.
  21. 30Clark 2013Clark K, Vendt B, Smith K, et al. The cancer imaging archive (TCIA): maintaining and operating a public information repository. J Digit Imaging. 2013; 26: 1045-1057.
  22. 31Wilkinson 2016Wilkinson MD, Dumontier M, Aalbersberg IJ, Appleton G, Axton M, Baak A, Blomberg N, Boiten JW, da Silva Santos LB, Bourne PE, Bouwman J. The FAIR Guiding Principles for scientific data management and stewardship. Scientific data 2016; 3(1):160018.
  23. 32Mildenberger 2002Mildenberger P, Eichelberg M, Martin E. Introduction to the DICOM standard. European radiology. 2002 Apr;12(4):920-7.
  24. 33Haibe-Kains 2020Haibe-Kains B, Adam GA, Hosny A, et al. Transparency and reproducibility in artificial intelligence. Nature 2020;586:E14–E16.
  25. 34Hurkmans 2024Hurkmans C, Bibault J-E, Brock KK, et al. A joint ESTRO and AAPM guideline for development, clinical validation and reporting of artificial intelligence models in radiation therapy. Radiother Oncol 2024;197:110345.
  26. 35Gillies 2015Gillies RJ, Kinahan PE, Hricak H. Radiomics: images are more than pictures, they are data. Radiology. 2015; 278: 563-577.
  27. 36Morin 2018Morin O, Vallières M, Jochems A, et al. A deep look into the future of quantitative imaging in oncology: a statement of working principles and proposal for change. Int J Radiat Oncol Biol Phys. 2018; 102: 1074-1082.
  28. 37Aerts 2014Aerts HJWL, Velazquez ER, Leijenaar RTH, et al. Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nat Commun 2014;5:4006.
  29. 38Vallières 2017Vallières M, Kay-Rivest E, Perrin LJ, et al. Radiomics strategies for risk assessment of tumour failure in head-and-neck cancer. Sci Rep 2017;7:10117.
  30. 39Nikolov 2021Nikolov S, Blackwell S, Zverovitch A, et al. Clinically applicable segmentation of head and neck anatomy for radiotherapy: deep learning algorithm development and validation study. J Med Internet Res. 2021; 23:e26151.
  31. 40Oreiller 2022Oreiller V, Andrearczyk V, Jreige M, et al. Head and neck tumor segmentation in PET/CT: the HECKTOR challenge. Med Image Anal. 2022; 77:102336.
  32. 41Cardenas 2020Cardenas CE, Mohamed AS, Yang J, Gooding M, Veeraraghavan H, Kalpathy‐Cramer J, Ng SP, Ding Y, Wang J, Lai SY, Fuller CD. Head and neck cancer patient images for determining auto‐segmentation accuracy in T2‐weighted magnetic resonance imaging through expert manual segmentations. Medical physics. 2020 May;47(5):2317-22.
  33. 42Ang 2014Ang KK, Zhang Q, Rosenthal DI, Nguyen-Tan PF, Sherman EJ, Weber RS, Galvin JM, Bonner JA, Harris J, El-Naggar AK, Gillison ML. Randomized phase III trial of concurrent accelerated radiation plus cisplatin with or without cetuximab for stage III to IV head and neck carcinoma: RTOG 0522. Journal of clinical oncology. 2014 Sep 20;32(27):2940-50.
  34. 43Wee 2019Wee L, Dekker A. Data from HEAD-NECK-RADIOMICS-HN1 [Data set]. The Cancer Imaging Archive; 2019.
  35. 44Beichel 2015Beichel RR, Ulrich EJ, Bauer C, Wahle A, Brown B, Chang T, Plichta K, Smith B, Sunderland J, Braun T, Fedorov A, Clunie D, Onken M, Magnotta VA, Menda Y, Riesmeier J, Pieper S, Kikinis R, Graham MM, Casavant TL, Sonka M, Buatti J. Data From QIN-HEADNECK (Version 4) [Data set]. The Cancer Imaging Archive; 2015.
  36. 45Zuley 2016Zuley ML, Jarosz R, Kirk S, Lee Y, Colen R, Garcia K, Delbeke D, Pham M, Nagy P, Sevinc G, Goldsmith M, Khan S, Net JM, Lucchesi FR, Aredes ND. The Cancer Genome Atlas Head-Neck Squamous Cell Carcinoma Collection (TCGA-HNSC) (Version 6) [Data set]. The Cancer Imaging Archive; 2016.
  37. 46Grossberg 2018Grossberg AJ, Mohamed AS, Elhalawani H, Bennett WC, Smith KE, Nolan TS, Williams B, Chamchod S, Heukelom J, Kantor ME, Browne T. Imaging and clinical data archive for head and neck squamous cell carcinoma patients treated with radiotherapy. Scientific data. 2018 Sep 4;5(1):180173.
  38. 47Wong 2010Wong K, Huang SH, O’Sullivan B, Lockwood G, Dale D, Michaelson T, Waldron J, Bayley A, Cummings B, Dawson LA, Kim J. Point-of-care outcome assessment in the cancer clinic: audit of data quality. Radiotherapy and oncology. 2010 Jun 1;95(3):339-43.
  39. 48Lowekamp 2013Lowekamp BC, Chen DT, Ibáñez L, Blezek D. The design of SimpleITK. Frontiers in neuroinformatics. 2013 Dec 30;7:45.
  40. 49Mayo 2018Mayo CS, Moran JM, Bosch W, Xiao Y, McNutt T, Popple R, Michalski J, Feng M, Marks LB, Fuller CD, Yorke E. American Association of Physicists in Medicine Task Group 263: standardizing nomenclatures in radiation oncology. International Journal of Radiation Oncology* Biology* Physics. 2018 Mar 15;100(4):1057-66.
  41. 50Grégoire 2014Grégoire V, Ang K, Budach W, Grau C, Hamoir M, Langendijk JA, Lee A, Le QT, Maingon P, Nutting C, O’Sullivan B. Delineation of the neck node levels for head and neck tumors: a 2013 update. DAHANCA, EORTC, HKNPCSG, NCIC CTG, NCRI, RTOG, TROG consensus guidelines. Radiotherapy and oncology. 2014 Jan 1;110(1):172-81.
  42. 51Lubner 2017Lubner MG, Smith AD, Sandrasegaran K, Sahani DV, Pickhardt PJ. CT texture analysis: definitions, applications, biologic correlates, and challenges. Radiographics. 2017 Sep;37(5):1483-503.
  43. 52Zhao 2022Zhao Y, Bao D, Wang X, Lin M, Li L, Zhu Z, Zhao X, Luo D. Prediction model based on preoperative CT findings for carotid artery invasion in patients with head and neck masses. Frontiers in Oncology. 2022 Oct 6;12:987031.
  44. 53Carlton 2017Carlton JA, Maxwell AW, Bauer LB, McElroy SM, Layfield LJ, Ahsan H, Agarwal A. Computed tomography detection of extracapsular spread of squamous cell carcinoma of the head and neck in metastatic cervical lymph nodes. The neuroradiology journal. 2017 Jun;30(3):222-9.
  45. 54Reiazi 2021Reiazi R, Arrowsmith C, Welch M, Abbas-Aghababazadeh F, Eeles C, Tadic T, Hope AJ, Bratman SV, Haibe-Kains B. Prediction of human papillomavirus (HPV) association of oropharyngeal cancer (OPC) using radiomics: the impact of the variation of CT scanner. Cancers. 2021 May 8;13(9):2269.
  46. 55Arrowsmith 2020Arrowsmith C, Reiazi R, Welch ML, Kazmierski M, Patel T, Rezaie A, Tadic T, Bratman S, Haibe-Kains B. A hybrid algorithm for dental artifact detection in large computed tomography datasets. medRxiv. 2020 Aug 7:2020-08.
  47. 56Mateus 2023Mateus P, Volmer L, Wee L, Aerts HJ, Hoebers F, Dekker A, Bermejo I. Image based prognosis in head and neck cancer using convolutional neural networks: a case study in reproducibility and optimization. Scientific Reports. 2023 Oct 24;13(1):18176.
  48. 57Bogowicz 2017Bogowicz M, Riesterer O, Stark LS, Studer G, Unkelbach J, Guckenberger M, Tanadini-Lang S. Comparison of PET and CT radiomics for prediction of local tumor control in head and neck squamous cell carcinoma. Acta oncologica. 2017 Nov 2;56(11):1531-6.
  49. 58Bogowicz 2019Bogowicz M, Vuong D, Huellner MW, Pavic M, Andratschke N, Gabrys HS, Guckenberger M, Tanadini-Lang S. CT radiomics and PET radiomics: ready for clinical implementation?. Q J Nucl Med Mol Imaging 2019 Sep 13;63(4):355-70.
  50. 59Tomaszewski 2021Tomaszewski MR, Gillies RJ. The biological meaning of radiomic features. Radiology. 2021 Mar;298(3):505-16.
  51. 60Brant 2012Brant WE, Helms CA: Fundamentals of Diagnostic Radiology. 2012.
  52. 61Law 2009Law MY, Liu B. DICOM-RT and its utilization in radiation therapy. Radiographics. 2009 May;29(3):655-67.
  53. 62Deng 2009Deng J, Dong W, Socher R, Li LJ, Li K, Fei-Fei L. Imagenet: A large-scale hierarchical image database. IEEE conference on computer vision and pattern recognition 2009 Jun 20 (pp. 248-255). IEEE.
  54. 63Sabottke 2020Sabottke CF, Spieler BM. The effect of image resolution on deep learning in radiography. Radiology: Artificial Intelligence. 2020 Jan 22;2(1):e190015.
  55. 64Pinter 2012Pinter C, Lasso A, Wang A, Jaffray D, Fichtinger G. SlicerRT: radiation therapy research toolkit for 3D Slicer. Medical physics. 2012 Oct;39(10):6332-8.
  56. 65Pieper 2004Pieper S, Halle M, Kikinis R. 3D Slicer. 2nd IEEE international symposium on biomedical imaging 2004 Apr 18 (pp. 632-635). IEEE.
  57. 66Gorgolewski 2016Gorgolewski KJ, Auer T, Calhoun VD, Craddock RC, Das S, Duff EP, Flandin G, Ghosh SS, Glatard T, Halchenko YO, Handwerker DA. The brain imaging data structure, a format for organizing and describing outputs of neuroimaging experiments. Scientific data. 2016 Jun 21;3(1):160044.
  58. 67Hong 2022Hong J, Reyngold M, Crane C, Cuaron J, Hajj C, Mann J, Zinovoy M, Yorke E, LoCastro E, Apte AP, Mageras G. CT and cone-beam CT of ablative radiation therapy for pancreatic cancer with expert organ-at-risk contours. Scientific Data. 2022 Oct 21;9(1):637.
  59. 68Kwan 2019Kwan JYY, Su J, Huang SH, Ghoraie LS, Xu W, Chan B, Yip KW, Giuliani M, Bayley A, Kim J, Hope AJ, Ringash J, Cho J, McNiven A, Hansen A, Goldstein D, de Almeida JR, Aerts HJ, Waldron JN, Haibe-Kains B, O’Sullivan B, Bratman SV, Liu FF. Data from Radiomic Biomarkers to Refine Risk Models for Distant Metastasis in Oropharyngeal Carcinoma. The Cancer Imaging Archive. 2019.
  60. 69NLST 2011National Lung Screening Trial Research Team. Reduced lung-cancer mortality with low-dose computed tomographic screening. New England Journal of Medicine. 2011 Aug 4;365(5):395-409.
  61. 70van Griethuysen 2017van Griethuysen JJM, Fedorov A, Parmar C, et al. Computational Radiomics System to Decode the Radiographic Phenotype. Cancer Res 2017;77(21):e104–e107.
  62. 71Ding 2005Ding C, Peng H. Minimum redundancy feature selection from microarray gene expression data. Journal of bioinformatics and computational biology. 2005 Apr;3(02):185-205.
  63. 72Yu 2011Yu C-N, Greiner R, Lin H-C, Baracos V. Learning Patient-Specific Cancer Survival Distributions as a Sequence of Dependent Regressors. NIPS 24, 2011.
  64. 73Lee 2018Lee C, Zame WR, Yoon J, van der Schaar M. DeepHit: A Deep Learning Approach to Survival Analysis with Competing Risks. AAAI-18:2314–2321.
  65. 74Kalbfleisch 2002Kalbfleisch JD, Prentice RL. The Statistical Analysis of Failure Time Data. 2nd ed. Wiley; 2002.
  66. 75Fotso 2018Fotso S. Deep Neural Networks for Survival Analysis Based on a Multi-Task Framework. arXiv:1801.05512, 2018.
  67. 76Paszke 2019Paszke A, Gross S, Massa F, Lerer A, Bradbury J, Chanan G, Killeen T, Lin Z, Gimelshein N, Antiga L, Desmaison A, Köpf A, Yang E, DeVito Z, Raison M, Tejani A, Chilamkurthy S, Steiner B, Fang L, Bai J, Chintala S. PyTorch: An Imperative Style, High-Performance Deep Learning Library. Advances in Neural Information Processing Systems 32. 2019:8024–8035.
  68. 77Falcon 2019Falcon WA. PyTorch Lightning. GitHub; 2019. https://github.com/PyTorchLightning/pytorch-lightning
  69. 78Harrell 1996Harrell FE, Lee KL, Mark DB. Multivariable prognostic models: issues in developing models, evaluating assumptions and adequacy, and measuring and reducing errors. Stat Med 1996;15(4):361–387.
  70. 79Ger 2019Ger RB, Zhou S, Elgohari B, Elhalawani H, Mackin DM, Meier JG, Nguyen CM, Anderson BM, Gay C, Ning J, Fuller CD, Li H, Howell RM, Layman RR, Mawlawi O, Stafford RJ, Aerts H, Court LE. Radiomics features of the primary tumor fail to improve prediction of overall survival in large cohorts of CT- and PET-imaged head and neck cancer patients. PLoS ONE 2019;14(9):e0222509.
  71. 80Pai 2024Pai S, Bontempi D, Hadzic I, Prudente V, Sokač M, Chaunzwa TL, Bernatz S, Hosny A, Mak RH, Birkbak NJ, Aerts HJWL. Foundation model for cancer imaging biomarkers. Nat Mach Intell 2024;6:354–367.
  72. 81Choi 2020Choi Y, Nam Y, Jang J, Shin N-Y, Ahn K-J, Kim B-S, Lee Y-S, Kim M-S. Prediction of Human Papillomavirus Status and Overall Survival in Patients with Untreated Oropharyngeal Squamous Cell Carcinoma: Development and Validation of CT-Based Radiomics. AJNR Am J Neuroradiol 2020;41(10):1897–1904.
  73. 82Fan 2023Ming Fan, Kailang Wang, You Zhang, Yuanyuan Ge, Zhong Lü, and Lihua Li. Radiogenomic analysis of cellular tumor-stroma heterogeneity as a prognostic predictor in breast cancer. Journal of Translational Medicine., 21(1):851, November 2023.
  74. 83Sun 2018Roger Sun, Elaine Johanna Limkin, Maria Vakalopoulou, Laurent Dercle, Stéphane Champiat, Shan Rong Han, Loïc Verlingue, David Brandao, Andrea Lancia, Samy Ammari, Antoine Hollebecque, Jean-Yves Scoazec, Aurélien Marabelle, Christophe Massard, Jean-Charles Soria, Charlotte Robert, Nikos Paragios, Eric Deutsch, and Charles Ferté. A radiomics approach to assess tumour-infiltrating CD8 cells and response to anti-PD-1 or anti-PD-L1 immunotherapy: an imaging biomarker, retrospective multicohort study. Lancet Oncology, 19(9):1180–1191, September 2018.
  75. 84Zhang 2025Rui Zhang, Chunfan Jiang, Feng Li, Lin Li, Xiaomin Qin, Jiang Yang, Huabing Lv, Tao Ai, Lei Deng, Chencui Huang, Hui Xing, and Feng Wu. Preoperative MRI-based radiomics analysis of intra- and peritumoral regions for predicting CD3 expression in early cervical cancer. Scientific Reports, 15(1):26754, July 2025.
  76. 85Isensee 2021Isensee F, Jaeger PF, Kohl SAA, Petersen J, Maier-Hein KH. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat Methods 2021;18:203–211.
  77. 86Kim 2023Kim JW, Marsilla J, Kazmierski M, Tkachuk D, Huang SH, Xu W, Cho J, Ringash J, Bratman S, Haibe-Kains B, Hope A. Effect of radiation therapy quality assurance on nasopharyngeal carcinoma: usage of a novel, web-based quality assurance application. Practical Radiation Oncology 2023;13(4):e354-64.
  78. 87Brouwer 2014Brouwer CL, Steenbakkers RJHM, Gort E, Kamphuis ME, van der Laan HP, van't Veld AA, Sijtsema NM, Langendijk JA. Differences in delineation guidelines for head and neck cancer result in inconsistent reported dose and corresponding NTCP. Radiother Oncol 2014;111:148–152.
  79. 88van Dijk 2020van Dijk LV, Van den Bosch L, Aljabar P, Peressutti D, Both S, Steenbakkers RJHM, Langendijk JA, Gooding MJ, Brouwer CL. Improving automatic delineation for head and neck organs at risk by Deep Learning Contouring. Radiother Oncol 2020;142:115–123.
  80. 89Huang 2020Huang SH, et al. Prognostic importance of radiologic extranodal extension in HPV-positive oropharyngeal carcinoma and its potential role in refining TNM-8 cN-classification. Radiother Oncol 2020;144:13–22.
  81. 90Henson 2024Henson C, Abou-Foul AK, Yu E, et al. Criteria for the diagnosis of extranodal extension detected on radiological imaging in head and neck cancer: Head and Neck Cancer International Group consensus recommendations. Lancet Oncol 2024;25:e297–e307.
  82. 91Hoebers 2022Hoebers F, Yu E, O'Sullivan B, Postma AA, Palm WM, Bartlett E, Lee J, Stock S, Koyfman S, Xu W, Su J, Huang SH. Augmenting inter-rater concordance of radiologic extranodal extension in HPV-positive oropharyngeal carcinoma: A multicenter study. Head Neck 2022;44:2361–2369.
  83. 92Tavaziva 2022Tavaziva G, Harris M, Abidi SK, et al. Chest X-ray analysis with deep learning-based software as a triage test for pulmonary tuberculosis: an individual patient data meta-analysis of diagnostic accuracy. Clin Infect Dis. 2022;74(8):1390-1400.
  84. 93Yacoub 2022Yacoub B, Varga-Szemes A, Schoepf UJ. Impact of artificial intelligence assistance on chest CT interpretation times: a prospective randomized study. AJR Am J Roentgenol. 2022;219(5):743-751.
  85. 94He 2016He K, Zhang X, Ren S, Sun J. Deep Residual Learning for Image Recognition. Computer Vision and Pattern Recognition Conference (CVPR). 2016.
  86. 95Kingma 2015Kingma DP, Ba J. Adam: A Method for Stochastic Optimization. International Conference on Learning Representations (ICLR). 2015.
  87. 96Ayhan 2018Ayhan MS, Berens P. Test-time Data Augmentation for Estimation of Heteroscedastic Aleatoric Uncertainty in Deep Neural Networks. Medical Imaging with Deep Learning (MIDL). 2018.
  88. 97Shanmugam 2021Shanmugam D, Blalock D, Balakrishnan G, Guttag J. Better Aggregation in Test-Time Augmentation. International Conference on Computer Vision (ICCV). 2021.
  89. 98O'Sullivan 2017O'Sullivan B, Lydiatt WM, Haughey BH, Brandwein-Gensler M, Glastonbury CM, Shah JP. HPV-Mediated (p16+) Oropharyngeal Cancer. AJCC Cancer Staging Manual. 8th edition. Springer; 2017:113-121.
  90. 99O'Sullivan 2020O'Sullivan B, Huang SH, de Almeida JR, Hope A. Alpha Test of Intelligent Machine Learning in Staging Head and Neck Cancer. J Clin Oncol 2020;38(12):1255–1257.
  91. 100Watson 2024Watson EE, Hueniken K, Lee J, Huang SH, El Maghrabi A, Xu W, Moreno AC, Tsai CJ, Hahn E, McPartlin AJ, Yao CMKL, Goldstein DP, De Almeida JR, Waldron JN, Fuller CD, Hope AJ, Ruggiero SL, Glogauer M, Hosni AA. Development and Standardization of an Osteoradionecrosis Classification System in Head and Neck Cancer: Implementation of a Risk-Based Model. J Clin Oncol 2024;42(16):1922–1933.
  92. 101Buglione 2016Buglione M, Cavagnini R, Di Rosario F, et al.; Russi EG, Magrini SM. Oral toxicity management in head and neck cancer patients treated with chemotherapy and radiation: Dental pathologies and osteoradionecrosis (Part 1) literature review and consensus statement. Crit Rev Oncol Hematol 2016;97:131–142.
  93. 102Peterson 2024Peterson DE, et al. Prevention and Management of Osteoradionecrosis in Patients With Head and Neck Cancer Treated With Radiation Therapy: ISOO-MASCC-ASCO Guideline. J Clin Oncol 2024;42(16):1975–1996.
  94. 103Watson 2021Watson E, Dorna Mojdami Z, Oladega A, Hope A, Glogauer M; Canadian Dental Oncology Network Consensus Group. Clinical practice guidelines for dental management prior to radiation for head and neck cancer. Oral Oncol 2021;123:105604.
  95. 104van Dijk 2025van Dijk LV, Humbert-Vidan L, Watson EE, Aponte Wesson RA, Jacomina LE, He R, Naser MA, Rhee DJ, Wang HC, Lai SY, Walji M, Witjes MJH, Katz MS, Hope A, Chambers MS, Fuller CD, Moreno AC. Radiation-specific Automated Dosimetric dental, Mandible, and maxilla Annotation for Predicting Periodontal Problems (RADMAP). medRxiv 2025.
  96. 105Mallya 2018Mallya SM, Lam EWN, eds. White and Pharoah’s Oral Radiology: Principles and Interpretation. 8th ed. Elsevier; 2018.
  97. 106Rondon 2014Rondon RHN, Pereira YCL, do Nascimento GC. Common positioning errors in panoramic radiography: A review. Imaging Sci Dent 2014;44(1):1–6.
  98. 107Fedorov 2012Fedorov A, Beichel R, Kalpathy-Cramer J, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging 2012;30(9):1323–1341.
  99. 108PerkLab 2026PerkLab (Laboratory for Percutaneous Surgery, Queen’s University). SlicerSandbox: extension for 3D Slicer, including the Curved Planar Reformat module. GitHub; 2026. https://github.com/PerkLab/SlicerSandbox
  100. 109Hao 2025Hao J, Liu M, He L, Yao L, Tsoi JKH, Hung KF. SemiT-SAM: Building A Visual Foundation Model for Tooth Instance Segmentation on Panoramic Radiographs. In: Wang Y, et al. (Eds.) MICCAI 2024, LNCS 15571, pp. 110–121. Springer, 2025.
  101. 110Wang 2026Wang Y, Li Z, Wu C, Liu J, Zhang Y, Ni J, Luo Q, Chen J, Zhang H, Liu J, Han C. MICCAI STS 2024 challenge: Semi-supervised instance-level tooth segmentation in panoramic X-ray and CBCT images. Medical Image Analysis. 2026 Feb 9:103986.
  102. 111Kuhn 1955Kuhn HW. The Hungarian method for the assignment problem. Nav Res Logist Q 1955;2(1–2):83–971.
  103. 112Rousseeuw 1984Rousseeuw PJ. Least median of squares regression. J Am Stat Assoc 1984;79(388):871–880.
  104. 113Fitzpatrick 1998Fitzpatrick JM, West JB, Maurer CR Jr. Predicting error in rigid-body point-based registration. IEEE Trans Med Imaging 1998;17(5):694–702.
  105. 114Nelson 2019Nelson SJ. Wheeler’s Dental Anatomy, Physiology, and Occlusion. 11th ed. Elsevier; 2019.
  106. 115Bland 1986Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1(8476):307–310.
  107. 116van Dijk 2021van Dijk LV, et al. Normal Tissue Complication Probability (NTCP) Prediction Model for Osteoradionecrosis of the Mandible in Patients With Head and Neck Cancer After Radiation Therapy: Large-Scale Observational Cohort. Int J Radiat Oncol Biol Phys 2021;111:549–558.
  108. 117Grant 2023Grant, Robert C., Muammar Kabir, Baijiang Yuan, Benjamin Grant, Sharon Narine, Kevin He, Rami Ajaj. An intelligent machine learning model for real-time early detection of undesirable cancer events: AIM2REDUCE. J Clin Oncol 2023;41:1557.
  109. 118Kabir 2024Kabir M, He JC, Yuan B, Tran V, Sue K, Patel T, Grant B, Li Y, Narine S, Welch M, Krzyzanowska MK. Prospective silent deployment and evaluation of an intelligent machine learning model for prediction of emergency department visits during cancer treatment. JCO Oncol Pract 2024;20:407.
  110. 119Gouthamchand 2024Gouthamchand V, Choudhury A, Hoebers FJP, Wesseling FWR, Welch M, Kim S, Kazmierska J, Dekker A, Haibe-Kains B, van Soest J, Wee L. Making head and neck cancer clinical data Findable-Accessible-Interoperable-Reusable to support multi-institutional collaboration and federated learning. BJR|Artif Intell 2024;1(1):ubae005.
  111. 120Choudhury 2025Choudhury A, Volmer L, Martin F, Fijten R, Wee L, Dekker A, van Soest J. Advancing Privacy-Preserving Health Care Analytics and Implementation of the Personal Health Train: Federated Deep Learning Study. JMIR AI, 2025;4:e60847
  112. 121Brierley 2025Brierley JD, Giuliani M, O’Sullivan B, Rous B, Van Eycken E, eds. TNM Classification of Malignant Tumours. 9th ed. Wiley; 2025.
  113. 122Saito 2015Saito T, Rehmsmeier M. The precision-recall plot is more informative than the ROC plot when evaluating binary classifiers on imbalanced datasets. PLoS One 2015;10(3):e0118432.
  114. 123Grégoire 2011Grégoire V, Mackie TR. State of the art on dose prescription, reporting and recording in Intensity-Modulated Radiation Therapy (ICRU report No. 83). Cancer Radiother 2011;15(6-7):555–9.
  115. 124Brouwer 2015Brouwer CL, Steenbakkers RJ, Bourhis J, et al. CT-based delineation of organs at risk in the head and neck region: DAHANCA, EORTC, GORTEC, HKNPCSG, NCIC CTG, NCRI, NRG Oncology and TROG consensus guidelines. Radiother Oncol 2015;117(1):83–90.
  116. 125Nutting 2011Nutting CM, Morden JP, Harrington KJ, et al. Parotid-sparing intensity modulated versus conventional radiotherapy in head and neck cancer (PARSPORT): a phase 3 multicentre randomised controlled trial. Lancet Oncol 2011;12(2):127–36.
  117. 126Davis 2017Davis AT, Palmer AL, Nisbet A. Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review. Br J Radiol 2017;90(1076):20160406.
  118. 127Hounsfield 1973Hounsfield GN. Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 1973;46(552):1016–22.
  119. 128Kalender 2006Kalender WA. X-ray computed tomography. Phys Med Biol 2006;51(13):R29–43.
  120. 129Goldman 2007aGoldman LW. Principles of CT and CT technology. J Nucl Med Technol 2007;35(3):115–28.
  121. 130Goldman 2007bGoldman LW. Principles of CT: radiation dose and image quality. J Nucl Med Technol 2007;35(4):213–25.
  122. 131Willemink 2019Willemink MJ, Noël PB. The evolution of image reconstruction for CT – from filtered back projection to artificial intelligence. Eur Radiol 2019;29(5):2185–2195.
  123. 132Cox 1972Cox DR. Regression models and life-tables. J R Stat Soc Series B 1972;34(2):187–220.
  124. 133Lambin 2012Lambin P, Rios-Velazquez E, Leijenaar R, et al. Radiomics: extracting more information from medical images using advanced feature analysis. Eur J Cancer 2012;48(4):441–6.
  125. 134Zwanenburg 2020Zwanenburg A, Vallières M, Abdalah MA, et al. The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping. Radiology 2020;295(2):328–338.
  126. 135Leijenaar 2015Leijenaar RT, Carvalho S, Hoebers FJ, et al. External validation of a prognostic CT-based radiomic signature in oropharyngeal squamous cell carcinoma. Acta Oncol 2015;54(9):1423–9.
  127. 136Leijenaar 2018Leijenaar RT, Bogowicz M, Jochems A, et al. Development and validation of a radiomic signature to predict HPV (p16) status from standard CT imaging: a multicenter study. Br J Radiol 2018;91(1086):20170498.
  128. 137Huang 2016Huang YQ, Liang CH, He L, et al. Development and Validation of a Radiomics Nomogram for Preoperative Prediction of Lymph Node Metastasis in Colorectal Cancer. J Clin Oncol 2016;34(18):2157–64.
  129. 138Kwan 2018Kwan JYY, Su J, Huang SH, et al. Radiomic Biomarkers to Refine Risk Models for Distant Metastasis in HPV-related Oropharyngeal Carcinoma. Int J Radiat Oncol Biol Phys 2018;102(4):1107–1116.
  130. 139Varma 2006Varma S, Simon R. Bias in error estimation when using cross-validation for model selection. BMC Bioinformatics 2006;7:91.
  131. 140Varoquaux 2022Varoquaux G, Cheplygina V. Machine learning for medical imaging: methodological failures and recommendations for the future. NPJ Digit Med 2022;5(1):48.
  132. 141LeCun 2015LeCun Y, Bengio Y, Hinton G. Deep learning. Nature 2015;521(7553):436–44.
  133. 142Litjens 2017Litjens G, Kooi T, Bejnordi BE, et al. A survey on deep learning in medical image analysis. Med Image Anal 2017;42:60–88.
  134. 143Yamashita 2018Yamashita R, Nishio M, Do RKG, Togashi K. Convolutional neural networks: an overview and application in radiology. Insights Imaging 2018;9(4):611–629.
  135. 144Hanley 1982Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143(1):29–36.
  136. 145DeLong 1988DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988;44(3):837–45.
  137. 146Vickers 2006Vickers AJ, Elkin EB. Decision curve analysis: a novel method for evaluating prediction models. Med Decis Making 2006;26(6):565–74.
  138. 147Vickers 2008Vickers AJ, Cronin AM, Elkin EB, Gonen M. Extensions to decision curve analysis, a novel method for evaluating diagnostic tests, prediction models and molecular markers. BMC Med Inform Decis Mak 2008;8:53.
  139. 148Van Calster 2019Van Calster B, McLernon DJ, van Smeden M, Wynants L, Steyerberg EW. Calibration: the Achilles heel of predictive analytics. BMC Med 2019;17(1):230.
  140. 149Park 2018Park SH, Han K. Methodologic Guide for Evaluating Clinical Performance and Effect of Artificial Intelligence Technology for Medical Diagnosis and Prediction. Radiology 2018;286(3):800–809.
  141. 150Kelly 2019Kelly CJ, Karthikesalingam A, Suleyman M, Corrado G, King D. Key challenges for delivering clinical impact with artificial intelligence. BMC Med 2019;17(1):195.

Glossary

Abbreviations

95HD
95th-percentile Hausdorff distance
AAPM
American Association of Physicists in Medicine
ACS
Axial–coronal–sagittal (convolutions)
AI
Artificial intelligence
AJCC
American Joint Committee on Cancer
AP
Average precision
ASHNR
American Society of Head and Neck Radiology
AUPRC
Area under the precision–recall curve
AUROC
Area under the receiver operating characteristic curve
CBCT
Cone-beam computed tomography
CDON
Canadian Dental Oncology Network
cENE
Clinically detected extranodal extension (physical examination)
CI
Confidence interval
CIF
Cumulative incidence function
CNN
Convolutional neural network
CPR
Curved planar reformation
CT
Computed tomography
CV
Cross-validation
DICOM
Digital Imaging and Communications in Medicine
DICOM-RT
DICOM radiotherapy objects: RTSTRUCT, RTDOSE, RTPLAN
DSC
Dice similarity coefficient
ECOG
Eastern Cooperative Oncology Group
EGFRI
Epidermal growth factor receptor inhibitor
EMR
Electronic medical record
ENE
Extranodal extension
ESTRO
European Society for Radiotherapy and Oncology
FDR
False discovery rate
FMCIB
Foundation Model for Cancer Imaging Biomarkers
FN
False negative
FOV
Field of view
FP
False positive
GLCM
Gray level co-occurrence matrix
GLDM
Gray level dependence matrix
GLRLM
Gray level run length matrix
GLSZM
Gray level size zone matrix
GPCC
Greater Poland Cancer Centre
GTV
Gross tumour volume
GTVn
Nodal gross tumour volume
GTVp
Primary gross tumour volume
Gy
Gray: unit of absorbed radiation dose
HNC
Head and neck cancer
HNCIG
Head and Neck Cancer International Group
HNSCC
Head and neck squamous cell carcinoma
HPV
Human papillomavirus
HR
Hazard ratio
HTV
High-risk target volume
HU
Hounsfield unit
iENE
Imaging-detected extranodal extension
IMRT
Intensity modulated radiotherapy
IQR
Interquartile range
KM
Kaplan–Meier
kVp
Peak kilovoltage (X-ray tube voltage)
LoA
Limits of agreement
MAR
Mean acceptability rating
MIRA
Princess Margaret internal software platform for radiotherapy imaging data management, research, and automation
ML
Machine learning
MRI
Magnetic resonance imaging
MTLR
Multi-task logistic regression
n.e.
Not estimable
NGTDM
Neighbouring gray tone difference matrix
NIfTI
Neuroimaging Informatics Technology Initiative
NPV
Negative predictive value
NTCP
Normal tissue complication probability
OAR
Organ at risk
OPC
Oropharyngeal carcinoma
ORN
Osteoradionecrosis
PACS
Picture archiving and communication system
Panorex
Panoramic radiograph
pENE
Pathologic extranodal extension (surgical specimen)
PET
Positron emission tomography
PH
Proportional hazards
PPV
Positive predictive value
PRC
Precision-recall curve
QC
Quality control
READII-2-ROQC
Radiomic Extraction and Analysis for DICOM Images to Refine Objective Quality Control
RMSE
Root-mean-square error
ROC
Receiver operating characteristic
ROI
Region of interest
RT
Radiotherapy
SCARF
auto-Segmentation Clinical Acceptability & Reproducibility Framework
SD
Standard deviation
SMD
Stnadardized mean difference
TCIA
The Cancer Imaging Archive
TG-263
AAPM Task Group 263, the radiation-oncology nomenclature standard
TN
True negative
TNM
Tumour–node–metastasis (staging)
TP
True positive
TTA
Test-time augmentation
UHN
University Health Network
UICC
Union for International Cancer Control
WOLNET
Volumetric 3D U-Net by Wolny et al.

Appendix

Supplementary materials

Supplementary Figure 1Kaplan-Meier curves for distant control comparing high-risk versus low-risk group stratification based on iENE determination across multiple thresholds (τ=[0.25, 0.50, 0.75]). The left most curves show the curves based on the clinician’s iENE determination. Each subfigure has two rows: top row with the early stages (stage I and stage II) subgroup and the bottom row with the late stages (stage III and stage IV) subgroup. Analyses are presented for both the held-out dataset (Supp Fig 1a - top row) and the Maastro external validation dataset (Supp Fig 1b - bottom row). Log-rank p-values are shown for each threshold. Numbers at risk are shown below each curve. This stratification demonstrates consistent prognostic discrimination across disease burden, supporting generalizability of the model in both early- and late-stage cohorts.
Supplementary Figure 2 Kaplan-Meier curves for distant control comparing high-risk versus low-risk group stratification based on iENE determination across multiple thresholds (τ=[0.25, 0.50, 0.75]). The left most curves show the curves based on the clinician’s iENE determination. Each subfigure has four rows, respectively covering different subgroups: HPV-positive and early stages (stage I and stage II), HPV-positive and late stages (stage III and stage IV), HPV-negative and early stages, and HPV-negative and late stages. Analyses are presented for both the held-out dataset (Supp Fig 2a - top row) and the Maastro external validation dataset (Supp Fig 2b - bottom row). Log-rank p-values are shown for each threshold. Numbers at risk are shown below each curve. This joint stratification isolates the HPV-positive early-stage subgroup central to the ECOG-ACRIN 3311 trial design, in which iENE determination most directly affects treatment selection.
Supplementary Figure 3iENE model performance by subgroup in the Maastro external cohort. Points are AUROCs and bars are 95% CIs from 2000 stratified bootstrap resamples. The solid line marks the AUROC in the whole cohort, and the dashed and dotted lines mark the RADCURE held-out set and its cN+ patients. Axial field of view and in-plane spacing form identical groups. Subgroups with fewer than two patients in either class are not shown.
Supplementary Table 1Descriptive statistics of patient demographics and clinical variables included in RADCURE.
Demographics
Age (years) 62.3(15.6-90.0)
Sex

Male

Female

2660(79.5%)

686(20.5%)

Smoking Status

Non-smoker

Ex-smoker

Current

Unknown

871(26.0%)

1289(38.5%)

1139(34.0%)

45(1.3%)

Clinical Variables
Disease Site

Oropharynx

Larynx

Nasopharynx

Hypopharynx

Oral Cavity

Nasal Cavity

Esophagus

Paranasal Sinus

Salivary Glands

Other/Unknown

1501(44.9%)

877(26.2%)

355(10.6%)

162(4.8%)

100(3.0%)

62(1.9%)

33(1.0%)

28(0.8%)

4(0.1%)

224(6.7%)

ECOG

ECOG 0

ECOG 1

ECOG 2

ECOG 3

ECOG 4

Unknown

2027(60.6%)

1031(30.8%)

209(6.2%)

41(1.2%)

6(0.2%)

31(0.9%)

N-Stage

N0

N1

N2

N2a

N2b

N2c

N3

N3a

N3b

NX

1147(34.3%)

344(10.3%)

182(5.4%)

125(3.7%)

791(23.6%)

532(15.9%)

170(5.1%)

28(0.8%)

13(0.4%)

1(0.03%)

T-Stage

T0

Tis

T1

T1a

T1b

T2

T2a

T2b

T3

T4

T4a

T4b

168(5.0%)

44(1.3%)

455(13.6%)

179(5.3%)

88(2.6%)

928(27.8%)

4(0.1%)

5(0.1%)

862(25.8%)

116(3.5%)

358(10.7%)

121(3.6%)

Overall Stage

0

I

II

III

IV

IVA

IVB

IVC

X

44(1.3%)

353(10.5%)

403(12.0%)

609(18.2%)

12(0.4%)

1581(47.3%)

309(9.2%)

2(0.06%)

6(0.2%)

Supplementary Table 2Top 20 radiomic features most changed by each negative control. Features are ranked by magnitude of change (%) between each original and negative-control image comparison. Feature names follow PyRadiomics nomenclature convention.
Rank shuffled
_full
sampled
_full
randomized_full shuffled
_roi
sampled
_roi
randomized_roi shuffled
_non_roi
sampled
_non_roi
randomized_non_roi
1 exponential_glszm_SmallAreaHighGrayLevelEmphasis exponential_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis
2 wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis square_glcm_ClusterProminence wavelet-HHH_glszm_SmallAreaEmphasis wavelet-HHH_glszm_SmallAreaEmphasis exponential_glszm_SmallAreaHighGrayLevelEmphasis exponential_glszm_SmallAreaHighGrayLevelEmphasis exponential_glszm_SmallAreaHighGrayLevelEmphasis exponential_glszm_SmallAreaHighGrayLevelEmphasis
3 square_glszm_SmallAreaHighGrayLevelEmphasis square_glszm_SmallAreaHighGrayLevelEmphasis exponential_glcm_ClusterProminence exponential_ngtdm_Coarseness exponential_ngtdm_Coarseness exponential_glszm_SmallAreaEmphasis square_glszm_SmallAreaHighGrayLevelEmphasis square_glszm_SmallAreaHighGrayLevelEmphasis square_glszm_SmallAreaHighGrayLevelEmphasis
4 square_glcm_ClusterProminence square_glcm_ClusterProminence exponential_glszm_SmallAreaHighGrayLevelEmphasis square_ngtdm_Coarseness square_ngtdm_Coarseness exponential_glcm_ClusterProminence wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis
5 exponential_glcm_ClusterProminence square_ngtdm_Complexity square_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaLowGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaLowGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaEmphasis wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis exponential_glszm_SmallAreaEmphasis
6 square_ngtdm_Complexity exponential_glcm_ClusterProminence square_ngtdm_Complexity exponential_glszm_SmallAreaHighGrayLevelEmphasis wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis exponential_glszm_SmallAreaLowGrayLevelEmphasis exponential_ngtdm_Coarseness exponential_ngtdm_Coarseness wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis
7 exponential_glszm_SmallAreaEmphasis exponential_glszm_SmallAreaEmphasis wavelet-HHL_glcm_ClusterProminence wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis exponential_glcm_ClusterProminence exponential_glcm_ClusterProminence square_glcm_ClusterProminence
8 exponential_ngtdm_Coarseness wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis exponential_ngtdm_Complexity exponential_glszm_SmallAreaEmphasis wavelet-LHH_glszm_SmallAreaEmphasis square_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glszm_SmallAreaEmphasis wavelet-HHH_glszm_SmallAreaEmphasis wavelet-HHL_glcm_ClusterProminence
9 wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis exponential_ngtdm_Coarseness wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HLH_glszm_SmallAreaEmphasis wavelet-HHH_glcm_ClusterProminence exponential_glszm_SmallAreaEmphasis exponential_glszm_SmallAreaEmphasis exponential_glszm_SmallAreaLowGrayLevelEmphasis
10 wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHH_glcm_ClusterProminence wavelet-LHH_glszm_SmallAreaEmphasis wavelet-HLH_glszm_SmallAreaLowGrayLevelEmphasis wavelet-HHL_glcm_ClusterProminence square_glszm_SmallAreaEmphasis square_glszm_SmallAreaEmphasis wavelet-HHH_glszm_SmallAreaEmphasis
11 square_glcm_ClusterShade square_glcm_ClusterShade square_glcm_ClusterShade wavelet-HLH_glszm_SmallAreaLowGrayLevelEmphasis wavelet-LHH_glszm_SmallAreaLowGrayLevelEmphasis exponential_ngtdm_Complexity square_glcm_ClusterProminence square_glcm_ClusterProminence wavelet-HHH_glcm_ClusterProminence
12 wavelet-HHH_glszm_SmallAreaEmphasis wavelet-HHH_glszm_SmallAreaEmphasis wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HLH_glszm_SmallAreaEmphasis exponential_glcm_MCC wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis wavelet-HHL_glcm_ClusterProminence exponential_glszm_SmallAreaLowGrayLevelEmphasis wavelet-LHH_glcm_ClusterProminence
13 exponential_glszm_SmallAreaLowGrayLevelEmphasis exponential_glszm_SmallAreaLowGrayLevelEmphasis exponential_glcm_ClusterShade exponential_glszm_SmallAreaLowGrayLevelEmphasis exponential_glszm_SmallAreaHighGrayLevelEmphasis square_glszm_SmallAreaEmphasis exponential_glszm_SmallAreaLowGrayLevelEmphasis wavelet-HHL_glcm_ClusterProminence wavelet-HLH_glcm_ClusterProminence
14 wavelet-HHL_glcm_ClusterProminence wavelet-HHL_glcm_ClusterProminence wavelet-LHH_glcm_ClusterProminence exponential_glcm_MCC wavelet-HHH_glcm_ClusterShade wavelet-HHH_glszm_SmallAreaLowGrayLevelEmphasis square_ngtdm_Complexity square_ngtdm_Complexity logarithm_glcm_ClusterProminence
15 square_ngtdm_Contrast square_ngtdm_Contrast wavelet-HLH_glcm_ClusterProminence wavelet-LHH_glszm_SmallAreaLowGrayLevelEmphasis wavelet-HHL_glcm_ClusterShade exponential_glcm_ClusterShade wavelet-LHL_glcm_ClusterProminence wavelet-HHH_glcm_ClusterShade wavelet-LHL_glcm_ClusterProminence
16 square_glszm_SmallAreaEmphasis square_glszm_SmallAreaEmphasis exponential_glszm_SmallAreaEmphasis wavelet-HHH_glcm_ClusterShade exponential_glcm_Correlation wavelet-HLH_glcm_ClusterProminence square_glszm_SmallAreaLowGrayLevelEmphasis square_glszm_SmallAreaLowGrayLevelEmphasis square_ngtdm_Complexity
17 wavelet-HHH_glcm_ClusterProminence wavelet-HHH_glcm_ClusterProminence wavelet-LHL_glcm_ClusterProminence wavelet-HHL_glcm_ClusterShade wavelet-HHL_glcm_ClusterProminence wavelet-LHH_glcm_ClusterProminence wavelet-HHH_glcm_ClusterProminence wavelet-HHH_glcm_ClusterProminence square_glszm_SmallAreaEmphasis
18 square_glcm_Contrast square_glcm_Contrast wavelet-HLL_glcm_ClusterProminence wavelet-HHL_glcm_ClusterProminence wavelet-HHH_glszm_ZoneVariance square_glszm_SmallAreaLowGrayLevelEmphasis exponential_glcm_ClusterShade exponential_glcm_ClusterShade wavelet-HLL_glcm_ClusterProminence
19 square_glcm_ClusterTendency square_glcm_ClusterTendency exponential_firstorder_Variance exponential_glcm_Correlation exponential_glszm_SmallAreaEmphasis wavelet-LHH_glszm_SmallAreaEmphasis wavelet-HHH_glcm_ClusterShade logarithm_glcm_ClusterProminence wavelet-HHH_glcm_ClusterShade
20 square_glcm_SumSquares square_glcm_SumSquares wavelet-HHH_glszm_SmallAreaEmphasis wavelet-HHH_glszm_ZoneVariance wavelet-HHH_glcm_ClusterProminence wavelet-HHH_glcm_ClusterShade logarithm_glcm_ClusterProminence wavelet-LHH_glcm_ClusterProminence exponential_ngtdm_Coarseness
Supplementary Table 3Top 10 radiomic features most changed across all negative controls. Average rank of each feature across 9 negative controls.
Rank Feature Average rank Mean magnitude (%)
1 wavelet-HHH_glszm_SmallAreaHighGrayLevelEmphasis 1.22 1.78×10¹¹
2 exponential_glszm_SmallAreaHighGrayLevelEmphasis 3.67 1.01×10¹¹
3 wavelet-LHH_glszm_SmallAreaHighGrayLevelEmphasis 6.56 8.00×10⁸
4 wavelet-HLH_glszm_SmallAreaHighGrayLevelEmphasis 8.33 4.89×10⁸
5 wavelet-HHH_glszm_SmallAreaEmphasis 8.78 8.93×10⁷
6 exponential_glszm_SmallAreaEmphasis 9.22 3.31×10⁸
7 wavelet-HHL_glcm_ClusterProminence 12.56 9.83×10⁸
8 exponential_glszm_SmallAreaLowGrayLevelEmphasis 14.44 5.08×10⁷
9 wavelet-HHH_glcm_ClusterProminence 15.44 4.14×10⁸
10 wavelet-HHH_glcm_ClusterShade 19.67 1.43×10⁷
ΔAUROC (95% CI), p-value Clinical Mixed Volume
iENE

0.232 (0.135–0.339)

p=0.001

0.127 (0.046–0.221)

p=0.002

0.062 (−0.004 to 0.134)

p=0.067

Volume

0.170 (0.093–0.255)

p=0.001

0.065 (0.019–0.125)

p=0.005

Mixed

0.105 (0.048–0.168)

p=0.001

Supplementary Table 4Paired bootstrap differences of AUROC and AUPRC on the RADCURE held-out set with 2000 draws. Each cell is the metric of the row model minus that of the column model, with its 95% bootstrap interval and two-sided p-value. iENE: deep learning model; Clinical, Mixed and Volume: baseline models of Ch.4.2.
ΔAUPRC (95% CI), p-value Clinical Mixed Volume
iENE

0.282 (0.085–0.489)

p=0.011

0.129 (−0.083 to 0.332)

p=0.219

+0.105 (−0.109 to 0.302)

p=0.334

Volume

0.177 (0.024–0.362)

p=0.032

0.024 (−0.051 to 0.107)

p=0.538

Mixed

0.153 (0.013–0.305)

p=0.033

Supplementary Table 5Unadjusted hazard ratios for distant control by deep learning model and volume baseline model-predicted iENE. Model-positive patients had a predicted probability of at least τ. Each hazard ratio is from a separate univariable Cox model, with distant control timed from the start of radiotherapy and censoring at last follow-up. RADCURE held-out test set: n=163, 22 events; *Estimated with an L2-penalised Cox model because the unpenalised model did not converge.
τ iENE HR (95% CI) Volume HR (95% CI)
0.25 5.07 (2.16–11.87) 4.56 (1.83–11.37)
0.50 8.30 (3.58–19.25) 2.99 (0.69–12.93)
0.75 6.29 (2.58–15.35)* 1.62 (0.22–12.13)
Supplementary Table 6Model performance and shift in predicted probability of the iENE model under READII-2-ROQC negative controls, with GTVp and largest GTVn as ROI. Each condition combines a permutation (shuffled, sampled, randomized) with a region. AUROC is against the radiologist’s iENE determination. Pearson r is the correlation between predictions on the original and control images. Residual SD is the standard deviation of the per-patient residual (original minus control prediction). p: DeLong test of the AUROC under the control against that on the original images in the same patients.
Type of control Largest GTVn GTVp

AUROC

p-value

Pearson
r
Residual SD AUROC
p-value
Pearson
r
Residual SD
original 0.908 1.000 - 0.908 1.000 -
shuffled ROI

0.877

p=0.197

0.987 0.045

0.907

p=0.662

0.997 0.020
sampled

0.878

p=0.176

0.986 0.047

0.908

p=0.914

0.997 0.020
randomized

0.865

p=0.025

0.793 0.172

0.873

p=0.117

0.966 0.071
shuffled non-ROI

0.472

p<0.001

0.102 0.268

0.496

p<0.001

0.006 0.269
sampled

0.517

p<0.001

0.123 0.268

0.515

p<0.001

0.005 0.269
randomized

0.441

p<0.001

−0.111 0.303

0.467

p<0.001

−0.085 0.301
shuffled Full

0.576

p<0.001

0.122 0.269

0.576

p<0.001

0.122 0.269
sampled

0.492

p<0.001

0.091 0.269

0.492

p<0.001

0.091 0.269
randomized

0.466

p<0.001

−0.083 0.301

0.466

p<0.001

−0.083 0.301
Supplementary Table 7Unpaired tests and standardized differences between all labelled RADCURE patients and the Maastro cohort. Values are median (IQR) or n (%), with missing values excluded from the denominator shown. SMD is the standardized difference (Maastro – RADCURE, pooled SD). p is from a Mann-Whitney or chi-square test, and q is the Benjamini-Hochberg adjusted p-value across the 17 tests. Acquisition geometry was extracted from the image headers.
Characteristic RADCURE (n=915) Maastro (n=175) SMD p q
Clinical
Age, years 60.9 (54.3–68.0) 62.1 (56.0–67.8) 0.11 0.158 0.168
Male sex 743 (81.2%) 131 (74.9%) −0.15 0.054 0.061
Smoking, pack-years 20.0 (0.0–40.0) 23.0 (6.0–36.0) 0.02 0.301 0.301
Smoking ≥10 pack-years 559/911 (61.4%) 122/169 (72.2%) 0.23 0.007 0.010
HPV positive 645/899 (71.7%) 101 (57.7%) −0.30 <0.001 <0.001
T3–T4 424/914 (46.4%) 99 (56.6%) 0.20 0.014 0.016
cN0 146 (16.0%) 0 (0.0%) −0.62 <0.001 <0.001
N category* N0: 146 (16.0%)
N1: 78 (8.5%)
N2: 636 (69.5%)
N3: 55 (6.0%)
N1: 93 (53.1%)
N2: 78 (44.6%)
N3: 4 (2.3%)
– <0.001 <0.001
Overall stage I: 456 (49.9%)
II: 189 (20.7%)
III: 96 (10.5%)
IV: 173 (18.9%)
I: 43 (24.6%)
II: 24 (13.7%)
III: 45 (25.7%)
IV: 63 (36.0%)
– <0.001 <0.001
Stage III–IV 269/914 (29.4%) 108 (61.7%) 0.69 <0.001 <0.001
Treatment Chemo-RT 467 (51.0%)
RT alone 410 (44.8%)
RT + EGFR inhibitor 38 (4.2%)
Chemo-RT 116 (66.3%)
RT alone 59 (33.7%)
– <0.001 <0.001
Concurrent chemo-RT 467 (51.0%) 116 (66.3%) 0.31 <0.001 <0.001
iENE positive 167 (18.3%) 60 (34.3%) 0.37 <0.001 <0.001
Acquisition
Slice thickness, mm 2.00 (2.00–2.00) 3.00 (3.00–3.00) 5.09 <0.001 <0.001
In-plane spacing, mm 0.976 (0.938–0.976) 0.977 (0.977–1.367) 1.50 <0.001 <0.001
Axial field of view, mm 499.7 (480.3–499.7) 500.0 (500.0–700.0) 1.50 <0.001 <0.001
Supplementary Table 8Discrimination and errors of iENE model by subgroup at τ=0.50. AUROC intervals are 95% CIs from 2000 stratified bootstrap resamples. Mean is the average of the model’s output probabilities. The false-negative rate is the proportion of iENE-positive patients scored below 0.50, and the false-positive rate is the proportion of iENE-negative patients scored at 0.50 or above it. A dash marks a subgroup with fewer than two patients in either class.
Subgroup n (iENE+) Mean AUROC (95% CI) False-negative rate False-positive rate
RADCURE held-out set
All patients 163 (25) 0.18 0.913 (0.856–0.959) 10/25 (40.0%) 9/138 (6.5%)
cN0 28 (0) 0.04 – – 0/28 (0.0%)
cN+ 135 (25) 0.20 0.897 (0.828–0.951) 10/25 (40.0%) 9/110 (8.2%)
Maastro external cohort
All patients 175 (60) 0.40 0.671 (0.578–0.760) 23/60 (38.3%) 33/115 (28.7%)
Label modality

MRI

75 (24) 0.42 0.749 (0.620–0.861) 6/24 (25.0%) 14/51 (27.5%)

CT

21 (8) 0.48 0.769 (0.538–0.952) 1/8 (12.5%) 4/13 (30.8%)

PET-CT

79 (28) 0.35 0.571 (0.414–0.721) 16/28 (57.1%) 15/51 (29.4%)
Axial field of view

500mm or less

107 (36) 0.49 0.767 (0.658–0.859) 6/36 (16.7%) 28/71 (39.4%)

Above 500mm

68 (24) 0.25 0.605 (0.446–0.746) 17/24 (70.8%) 5/44 (11.4%)
Label modality by axial field of view

PET-CT,
500mm or less

41 (12) 0.49 0.779 (0.583–0.940) 3/12 (25.0%) 13/29 (44.8%)

PET-CT,
above 500mm

38 (16) 0.21 0.511 (0.318–0.705) 13/16 (81.3%) 2/22 (9.1%)

MRI or CT,
500mm or less

66 (24) 0.49 0.769 (0.633–0.884) 3/24 (12.5%) 15/42 (35.7%)

MRI or CT,
above 500mm

30 (8) 0.30 0.756 (0.557–0.920) 4/8 (50.0%) 3/22 (13.6%)

All except PET-CT above 500mm

137 (44) 0.45 0.754 (0.657–0.840) 10/44 (22.7%) 31/93 (33.3%)
N category

N1

93 (29) 0.34 0.592 (0.453–0.730) 16/29 (55.2%) 16/64 (25.0%)

N2

78 (28) 0.45 0.717 (0.592–0.842) 7/28 (25.0%) 17/50 (34.0%)

N3

4 (3) 0.66 – 0/3 (0.0%) 0/1 (0.0%)
HPV status

Negative

74 (23) 0.41 0.706 (0.558–0.840) 7/23 (30.4%) 14/51 (27.5%)

Positive

101 (37) 0.39 0.652 (0.531–0.768) 16/37 (43.2%) 19/64 (29.7%)
Overall stage

I–II

67 (21) 0.35 0.619 (0.453–0.776) 11/21 (52.4%) 10/46 (21.7%)

III–IV

108 (39) 0.43 0.701 (0.585–0.815) 12/39 (30.8%) 23/69 (33.3%)
T category

T1–T2

76 (19) 0.33 0.636 (0.472–0.789) 10/19 (52.6%) 13/57 (22.8%)

T3–T4

99 (41) 0.45 0.669 (0.548–0.779) 13/41 (31.7%) 20/58 (34.5%)
Sex

Female

44 (11) 0.40 0.733 (0.523–0.909) 4/11 (36.4%) 7/33 (21.2%)

Male

131 (49) 0.39 0.657 (0.550–0.753) 19/49 (38.8%) 26/82 (31.7%)
Smoking

Under 10 pack-years

47 (20) 0.35 0.572 (0.394–0.752) 11/20 (55.0%) 7/27 (25.9%)

10 pack-years or more

122 (36) 0.41 0.715 (0.601–0.824) 11/36 (30.6%) 26/86 (30.2%)
Treatment

RT alone

59 (22) 0.40 0.636 (0.479–0.790) 9/22 (40.9%) 11/37 (29.7%)

Concurrent chemo-RT

116 (38) 0.39 0.690 (0.576–0.801) 14/38 (36.8%) 22/78 (28.2%)
Supplementary Table 9Association of patient, labelling and acquisition factors with errors of iENE model in the Maastro cohort at τ=0.50. False negatives were tested among the 60 iENE-positive patients (23 errors) and false positives among the 115 iENE-negative patients (33 errors). Categorical factors were tested with a chi-square test, or a Fisher exact test for 2×2 tables with an expected count below 5. Continuous factors were tested with a Mann-Whitney test. q is the Benjamini-Hochberg adjusted p-value within each error type and within the four interaction tests. The interaction is a likelihood-ratio test of the model’s output probability by the factor in a logistic model of iENE. Crop margin is the smallest distance from the larynx-centred crop to the edge of the image. n.e.: not estimable (no variation, or separation). *Expected count below 5 in a table larger than 2×2.
Factor False negatives False positives Score by factor interaction
p q p q p q
Labelling and acquisition
Label modality (MRI, CT, PET-CT) 0.016* 0.049 0.961* 1.000 0.028 0.056
Axial field of view, 500mm or less vs above <0.001 <0.001 0.001 0.006 – –
Axial field of view, mm <0.001 <0.001 0.001 0.006 0.003 0.013
Crop margin, mm 0.076 0.153 0.009 0.034 – –
Larynx-centred crop clipped 0.519 0.623 1.000 1.000 – –
Slice thickness, 2.5mm or less vs above n.e. n.e. 1.000 1.000 – –
Slice thickness, mm 1.000 1.000 0.538 0.930 n.e. n.e.
Clinical
N category (N1, N2, N3) 0.024* 0.062 0.468* 0.890 n.e. n.e.
HPV status 0.321 0.445 0.792 1.000 0.473 0.473
Overall stage, I–II vs III–IV 0.101 0.181 0.178 0.423 0.266 0.355
T category, T1–T2 vs T3–T4 0.121 0.198 0.166 0.423 – –
Sex 1.000 1.000 0.260 0.550 – –
Smoking, under 10 vs 10 or more pack-years 0.073 0.153 0.668 1.000 – –
Smoking, pack-years 0.315 0.445 0.849 1.000 – –
Concurrent chemo-RT 0.755 0.849 0.866 1.000 – –
Age, years 0.443 0.569 0.715 1.000 – –